Contact us
Call
Call us at
Available 6:00 AM – 5:00 PM (PST) Business Days
Download
Download Manuals, Datasheets, Software and more:
Feedback
Datasheets, Manuals, and Software Downloads
While we’re happy to “talk tech” with you all day long, we know you’re in a hurry.
So we’ve made it easy for you to download product manuals, datasheets and downloadable software which includes firmware, drivers, etc. for all our current products, and many discontinued products as well. Just tell us which product you’re using, and we’ll provide you with list of latest documents and resources that you can download.
The product model you have chosen is currently available for purchase. The following support information is available.
-
Datasheet Literature Number: ReleaseDate KickStart Instrument Control Software Datasheet
KickStart Software simplifies what you need to know about your instrument so that in just minutes you can take the instrument out of the box and get real data on your device. KickStart Software enables quick test setup and data visualization when …1KW-60965-16
-
Manuals Manual Type Part Number: ReleaseDate MDO4000C, MDO4000B, MDO4000, MSO4000B, DPO4000B, and MDO3000 Series Programmer Manual
Digital oscilloscopes programming commandsProgrammer Manuals 077051009 Tektronix Demo 3 Board Instruction Manual
Demo 3 Board Instruction ManualTraining/Tutorials 071286202 MSO4000B and DPO4000B Series Specifications and Performance Verification Manual
Digital Phosphor OscilloscopesSpecifications and Performance VerificationPerformance Verification 077050903 MSO4000B and DPO4000B Series User Manual
Digital Phosphor OscilloscopesPrimary User 071281004 RMD5000
Tektronix DPO & MSO 4000B Series and DPO & MSO5000/B Series Rackmount Kit InstructionsField Install Instructions 075102002 MSO4000B and DPO4000B Series and Application Modules Declassification and Security Instructions
Declassification and SecurityDeclassification Manuals 077051101 MSO4000B and DPO4000B Series Service Manual
Digital Phosphor OscilloscopesService Manuals 077051202 Read This First
Download the Latest IVI Drivers Read This FirstRelease Notes 061438100 HCTEK54 Transit Case Instructions
Transit CaseUser Manuals 071282800 MDO4000, MSO4000, MSO4000B, DPO4000, DPO4000B Series Application Module Installation Instructions
Application ModuleUser Manuals 071213601 Probe and Accessories Pouch Installation Instructions
Pouch InstallationField Install Instructions 071283000
-
Technical Documents Document Type ReleaseDate When to Choose a Dedicated Arbitrary Function Generator (AFG)
This technical brief is written to help you determine the optimum method of arbitrary function generation for your needs. It shows examples of real-world applications and highlights key specifications of Tektronix and Keithley dedicated arbitrary …Technical Brief Serial Support Using Tektronix Oscilloscopes and Optional Software
Tektronix oscilloscopes offer a portfolio of optional analysis capabilities to simplify serial bus debug or compliance verification. This selection matrix shows which serial standards are supported by each of the oscilloscope series.Product Selector Guide Measuring Power Supply Switching Loss with an Oscilloscope
Introduction With the demand for improving power efficiency and extending the operating time of battery-powered devices, the ability to analyze power loss and optimize power supply efficiency is more critical than ever …Application Note Probing Techniques for Accurate Voltage Measurements on Power Supplies with Oscilloscopes
This application note describes considerations and techniques for making accurate voltage measurements on power converters with an oscilloscope, especially as they relate to probe selection and application. It includes two examples for …Application Note How to Minimize Probe Loading with Low Capacitance Probes
Probing a circuit always has some impact on signals. Probe loading changes the signal being probed and can cause measurement problems or can even cause a circuit to perform differently. Reducing capacitive loading can help minimize these effects. In …Application Note Debugging Serial Buses in Embedded System Designs
Introduction Embedded systems are literally everywhere in our society today. A simple definition of an embedded system is a specialpurpose computer system that is part of a larger system or machine with the intended purpose of providing monitoring …Application Note How to Use a Mixed Signal Oscilloscope to Test Digital Circuits
The ability to present both analog and digital representations of signals make mixed signal oscilloscopes (MSOs) ideal for verifying and debugging digital circuits. This application note provides tips to help you efficiently debug …Application Note Wave Inspector® Navigation and Search: Simplifying Waveform Analysis
Modern digital oscilloscopes can capture massive amounts of data which must then be analyzed. Discover how the Tektronix Wave Inspector® navigation and search capability gives you the tools to extract the answers you need fast and efficiently.Application Note Making Accurate Current Measurements on Power Supplies with Oscilloscopes
This application note describes considerations and techniques for making accurate current measurements on power converters using an oscilloscope and a current probe. When used in conjunction with an oscilloscope’s voltage measurements capabilities …Application Note Smiths Detection Relies on Tektronix to Take the Trouble out of Troubleshooting
A team of engineers at Smith Detection needed to quickly, efficiently and accurately identify and resolve problems during the development of complex handheld devices. Learn how Smith Detection engineers used Tektronix bench instruments to identify a …Technical Brief iCub Robot Gets Battery Power with Help of Tektronix Oscilloscope, Voltage and Current Probes
Customer Solution Summary CHALLENGE Developers at the Istituto Italiano Di Tecnologia (IIT) needed to validate and troubleshoot a new battery backpack power supply system for the iCub robot, an open-source cognitive humanoid robot …Case Study Power Supply Measurement and Analysis Primer
A power supply is a component, subsystem, or system that converts electrical power from one form to another; commonly from alternating current (AC) utility power to direct current (DC) power. The proper operation of electronic devices ranging from …Primer How to Test a Power Supply with an Oscilloscope
Why Test Power Supplies with an Oscilloscope? Power supplies can be found in many different electronic devices, from children’s toys to computers and office equipment to industrial equipment. They are used to convert electrical power from one form …Application Note Introduction to Video Measurements
In this application note, we demonstrate using a MSO/DPO5000, MDO/MSO/DPO4000 and MDO/MSO/DPO3000 Series Oscilloscope to make a variety of video measurements that are common in standard and high definition systems.Application Note Testing a New Switch Mode Power Supply Design Poster
Get a quick overview of the key measurements for verifying a new switch mode power supply (SMPS) design. This poster shows key measurements, from verifying your prototype during initial startup, to optimizing switching loss and magnetic losses, to …Poster Tektronix MSO/DPO4000 Series vs. LeCroy WaveSurfer XS Fact Sheet
Serial Triggering and Decode Tektronix MSO/DPO3000 Series ✔ Simple time-correlated and labeled bus form display with color coded decode ✔ Wave Inspector® controls quickly navigate through long …Competitive MDO4000B Series vs. Agilent/Keysight MSOX4000A Series
When comparing oscilloscopes, check the details of the operation and look for “hidden” costs that prevent you from getting the versatility in performance you need to complete the wide-variety of fundamental measurement challenges you have today and …Competitive MSO/DPO4000B Series vs. Agilent MSO/DSO3000 X-Series
Side-by-side comparison on important features like serial triggering and decode, measurements and waveform math, digital debug with MSO, and more.Competitive Making MicroVolt Biomedical Measurements
Introduction Measuring electrical phenomena presents a number of unique challenges to biomedical signal measurement systems. The tiny, microVolt-level electrical pulses that signal a firing neuron or a muscle response are …Technical Brief 3000 X-Series vs. MSO/DPO4000B Series True Cost of Your Scope
Tektronix bench oscilloscopes are packed with innovative features to help you get your job done faster, built right into the scope. And, with a comprehensive set of probes and accessories included standard, you can start testing right out of the box …Competitive MSO/DPO4000 vs. Agilent MSO7000B Fact Sheet
Side-by-side comparison on important features like serial triggering and decode, waveform navigation and search, waveform capture rate, digital debug with MSO, and more.Competitive Tektronix MSO/DPO4000 Series vs. Agilent 5000A+ 6000A+ and 7000A Fact Sheet
Side-by-side comparison on important features like serial triggering and decode, waveform navigation and search, and record length.Competitive Tektronix MSO/DPO4000 Series vs. LeCroy WaveRunner Xi Fact Sheet
Side-by-side comparison on important features like serial triggering and decode, waveform navigation and search, and waveform capture rate.Competitive MSO/DPO4000 Series vs. Yokogawa DLM2000 Series
Side-by-side comparison on important features like serial triggering and decode, waveform navigation and search, user-experience, digital debug with a MSO and more.Competitive Tektronix MSO4000 Series vs. LeCroy MS-500 Mixed Signal Solution Fact Sheet
Side-by-side comparison on important features like display size, searching on analog and digital data, and setup and hold triggering.Competitive 10 Reasons Why You Have Never Seen a Mixed Signal Oscilloscope Like This
Learn more about all the innovative user-friendly features on the MSO4000 Series that have been designed to make your work easier.Brochure Tektronix MSO4000 Mixed Signal Oscilloscopes Win 2008 EDN China Innovation Award
Award DPO 4000B 3D CAD Models
Access the 3D CAD models for the DPO4000B 3D CAD Models, designed to support integration into mechanical layouts of test setups and laboratory environments. These files provide precise dimensional representations of the DPO4000B, aiding in the …CAD Files DPO 4000 3D CAD Models
Access the 3D CAD models for the DPO4000 3D CAD Models, designed to support integration into mechanical layouts of test setups and laboratory environments. These files provide precise dimensional representations of the DPO4000, aiding in the planning …CAD Files REVIEW: Cost-effective scopes time-correlate analog+ digital signals
Product Article Tektronix MSOs Set Performance Benchmarks
Product Article Portable Scopes Designed for Embedded Design and Debug
Product Article Test methodologies for high-speed serial designs
Product Article Tek oscilloscopes catch analog and digital signals
Product Article Oscilloscope Combines Logic Analyzer With Ease Of Use For Better Debugging
Product Article
-
Software Document Type Part Number: ReleaseDate KickStart Instrument Control Software version 2.11.5
Simply test automation with your instruments and KickStart software. Automate data collection across multiple instruments simultaneously. Control up to eight apps independently from a single PC interface. Save and reuse test …Application KICKSTART-2.11.5 KickStart Instrument Control Software version 2.11.4
KickStart Software for the PC enables quick test setup and data visualization when using one or more instruments. Key Features • Save time by automating data collection of millions of readings. • Set up a multi-instrument test with the ability to …Application KICKSTART-2.11.4 TEKVISA Connectivity Software - V5.11.1
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093813 KickStart Instrument Control Software Version 2.6.0 (Windows 10, 8, 7 compatible) (NOT SUPPORTED)
"KickStart Software for the PC enables quick test setup and data visualization when using one or more instruments.Key Features• Save time by automating data collection of millions of readings.• Set up a multi-instrument test with the ability to …Application KICKSTART-2.6.0 Tektronix Openchoice Desktop Application TDSPCS1 - V2.8
The Tektronix OpenChoice Desktop free application lets you capture oscilloscope screen images, waveform data, and settings from a Microsoft Windows computer. After installing the software, refer to the section “Connecting to a PC” in your …Utility 066093915 TEKVISA Connectivity Software - V4.2.0
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093812 DPO2000, MSO2000, DPO3000 and DPO4000, MSO3000 and MSO4000, MDO3000 and MDO4000 and MDO3 IVI Driver - V1.5
The Tektronix MSO/DPO2000, MDO/MSO/DPO3000, MDO/MSO/DPO4000 and MDO3 IVI Driver is an IVI class-compliant driver. It complies with Scope Class specifications (IVI-4.1) as defined by the IVI foundation. An IVI class-compliant specific driver for an …Driver 066133104 TEKVISA CONNECTIVITY SOFTWARE - V4.1.1
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093811 MSO4000B, DPO4000B Firmware - V3.22
This firmware is an upgrade for all MSO/DPO4000B Series oscilloscopes.Firmware 063447007 Tektronix Openchoice Desktop Application TDSPCS1 - v2.6
The Tektronix OpenChoice Desktop free application lets you capture oscilloscope screen images, waveform data, and settings from a Microsoft Windows computer. After installing the software, refer to the section “Connecting to a PC” in your …Utility 066093914 MSO4000B, DPO4000B Firmware, V3.20
This firmware is an upgrade for all MSO/DPO4000B Series oscilloscopes.Firmware 063447006 MSO4000B, DPO4000B Firmware, V3.18
This firmware is an upgrade for all MSO/DPO4000B Series oscilloscopes.Firmware 063447005 Tektronix Toolbars for Microsoft Office 32 bit - V4.0.4
Tektronix Toolbars for Microsoft Office v4.0.4 provide toolbars (add-ins) for the 32 bit versions of Microsoft Excel and Microsoft Word. This version of Toolbars requires OpenChoice TekVISA v4.0.4 (Part Number 066093809) to be preinstalled on the PC …Utility 066133202 MSO4000B, DPO4000B Firmware, V3.16
This firmware is an upgrade for all MSO/DPO4000B Series oscilloscopes.Firmware 063447004 TEKVISA CONNECTIVITY SOFTWARE, V4.0.4
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol. When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093809 MSO4000B, DPO4000B FIRMWARE, V2.96
This firmware is an upgrade for all MSO/DPO4000B Series oscilloscopes.Firmware 063447002 MSO4000B, DPO4000B FIRMWARE, V2.90
This firmware is an upgrade for all MSO/DPO4000B Series oscilloscopes.Firmware 063447001 DPO2000, DPO3000, DPO4000 IVI Driver
The Tektronix DPO2000, DPO3000, DPO4000 IVI Driver is an IVI class-compliant driver. It complies with Scope Class specifications (IVI-4.1) as defined by the IVI foundation. An IVI class-compliant specific driver for an oscilloscope exports the API …Driver 066133101 DPO4000B AND MSO4000B FIRMWARE V2.52
This firmware is an upgrade for all DPO4000B and MSO4000B Series oscilloscopes.Firmware 063432911 DPO4000 AND MSO4000 FIRMWARE V2.62
This firmware is an upgrade for all DPO4000 and MSO4000 Series oscilloscopes.Firmware 063397016 USING MATLAB WITH MSO_DPO4000 AND MSO_DPO3000 SERIES OSCILLOSCOPES v1.0
MATLAB is a software environment and programming language that enables Tektronix oscilloscope users to acquire and analyze data, graphically visualize data, make custom measurements, generate reports, and develop automated applications. Perform …Driver 066110000
-
FAQS FAQ ID Why does the Tkdpo2k3k4k_ReadWaveform() function in the Tkdpo2k3k4k IVI-C driver time out
Question: Why does the Tkdpo2k3k4k_ReadWaveform() function in the Tkdpo2k3k4k IVI-C driver time out every time I call it when I am connected to the instrument via Ethernet? The function call works fine over USB, but over Ethernet it always times out …KB-01425 My Tektronix oscilloscope uses the Linux operating system. Where do I get a copy of the linux open source code as stated in the GNU Lesser General Public License notice?
Question: My Tektronix oscilloscope uses the Linux operating system. Where do I get a copy of the linux open source code as stated in the GNU Lesser General Public License notice? Answer: For our Linux based instruments or programs licensed under …KB-01940 Will the P6516 Logic Probe work on my MSO4000B, MDO4000B and MDO4000C Series oscilloscopes?
Question: Will the P6516 Logic Probe work on my MSO4000B, MDO4000B and MDO4000C Series oscilloscopes? Answer: The P6516 logic probe was only used with the original MSO4000 series. For the subsequent MSO4000B, MDO4000B and MDO4000C …KB-01410 I cannot see my signal on the Oscilloscope. What can I do?
Question: I cannot see my signal on the Oscilloscope. What can I do? Answer: You have many options to help diagnose this issue, below are a few suggestions to get started. If you find yourself needing more help, please connect with our Technical …KB-02159 I downloaded and Installed OpenChoice Desktop, but it doesn't recognize my scope.
Question: I downloaded and Installed OpenChoice Desktop, but it doesn't recognize my scope. Answer: Refer to the Prerequisites.txt file available to download on the same page for OpenChoice desktop. Make sure you have all the prerequisites specified …KB-01333 How do I utilize the math channel feature on a DPO/MSO/MDO3000 or DPO/MSO/MDO4000 Series oscilloscope?
Question: How do I utilize the math channel feature on a DPO/MSO/MDO3000 or DPO/MSO/MDO4000 Series oscilloscope? Answer: There are three main functionalities on the Math button on this scope. They range from Dual Waveform Math, FFT (Fast Fourier …KB-01977 How do I set up an Ethernet bus decode?
Question: How do I set up an Ethernet bus decode? Answer: Make sure your setup is prepared to decode, that you have the needed probes, scope options, test boards, etc. Once you have the options it's important to know how to use the options and probe …KB-01963 How do I set up a CAN bus decode?
Question: How do I set up a CAN bus decode? Answer: Depending on the scope you have, the available options for decoding your CAN signal will depend on the compatibility. For all the DPO/MSO2000/3000/4000/5000 and MDO3000/4000 Series scopes, there are …KB-01959 How do I mount a network drive on my MDO3000 or MDO4000C oscilloscope?
Question: How do I mount a network drive on my MDO3000 or MDO4000C oscilloscope? Answer: This procedure also applies to the DPO/MSO/MDO4000/4000B series oscilloscopes. Note: This Mount a network drive will not work with a direct (peer-to-peer) …KB-01934 How do I run a Signal Path Compensation (SPC) on an DPO/MSO/MDO4000 Series oscilloscope?
Question: How do I run a Signal Path Compensation (SPC) on an DPO/MSO/MDO4000 Series oscilloscope? Answer: Signal Path Compensation (SPC) should be run anytime you are getting DC offsets in your signals, or your scope has moved locations and might …KB-01972 How Do I Set Up a Parallel Bus Decode?
Question: How Do I Set Up a Parallel Bus Decode? Answer: For doing Parallel Bus decode Tektronix recommends using a MSO or MDO + MSO option Series oscilloscopes. This feature comes standard in the Bus menu and can be used in a variety of ways. Start …KB-01955 How do I reduce noise on signals using an oscilloscope?
Question: How do I reduce noise on signals using an oscilloscope? Answer: There are many methods to reduce many types of noise on a signal. Tektronix oscilloscopes can do this through bandwidth limiting the scope input, averaging your signal …KB-01968 How do I use TekVISA to send commands to my instrument?
Question: How do I use TekVISA to send commands to my instrument? Answer: TekVISA Download Link:TEKVISA CONNECTIVITY SOFTWARE In order to communicate with and control the scope, you can use OpenChoice Talker-Listener. Back on the Application and …KB-01925 How do I download and install the 30-day trial version of NI LabVIEW SignalExpress Tektronix Edition?
Question: How do I download and install the 30-day trial version of NI LabVIEW SignalExpress Tektronix Edition? Answer: Note: NI LabVIEW SignalExpress Tektronix Edition is no longer offered by Tektronix. This FAQ is "historical only". National …KB-01933 How do I utilize the measurement features on a DPO/MSO/MDO3000 and DPO/MSO/MDO4000 Series oscilloscope?
Question: How do I utilize the measurement features on a DPO/MSO/MDO3000 and DPO/MSO/MDO4000 Series oscilloscope? Answer: The Measurements are the same as the DPO/MSO2000 Series scopes. By going into the measurement menu you can add and remove up to …KB-01978 How do I clear my memory using TekSecure on a MSO/DPO/MDO4000 Series oscilloscope?
Question: How do I clear my memory using TekSecure on a MSO/DPO/MDO4000 Series oscilloscope? Answer: This procedure for clearing the memory on oscilloscope can be applied to the DPO/MSO/MDO4000, DPO/MSO3000 and DPO/MSO2000 Series oscilloscope …KB-01971 Can the P6316, P6516, or P6616 logic probes be used interchangeably?
Question: Can the P6316, P6516, or P6616 logic probes be used interchangeably? Answer: The simple answer is no they can't be used interchangeably. The front end of the logic channels are different so different logic probes are needed between the …KB-02989 What is the difference between Position and Offset on an oscilloscope?
Question: What is the difference between Position and Offset on an oscilloscope? Answer: To answer this first you need to understand the layout of how your waveform trace is displayed. On your oscilloscope you generally will see either 8 or 10 …KB-01400 Do the existing MSO/DPO/MDO4000/B Series application modules work with the MDO4000C?
Question: Do the existing MSO/DPO/MDO4000/B Series application modules work with the MDO4000C? Answer: Yes, almost all work from all legacy MSO/DPO/MDO4000/B series scopes. The only one that has some requirements is the MDO4TRIG which requires a …KB-01438 What is the difference between the P6139A and the P6139B?
Question: What is the difference between the P6139A and the P6139B? Answer: From a specifications perspective, the probes are identical. Both are 500 MHz, 10X passive probes. The P6139B can be used on oscilloscopes that shipped with the P6139A. From …KB-02011 What are the primary differences between the DPO/MSO4000B, MDO4000, MDO4000B, and MDO4000C?
Question: What are the primary differences between the DPO/MSO4000B, MDO4000, MDO4000B, and MDO4000C? Answer: The 4000 Series Mixed Domain Oscilloscopes (MDO) a true RF/Time domain synchronized instrument. The major differences between revisions of …KB-01444 What probe interface does my oscilloscope have?
Question: What probe interface does my oscilloscope have? Answer: Oscilloscope seriesProbe interfaceCSA7000/CSA7000BTekConnectDPO2000TekVPIDPO3000TekVPIDPO4000TekVPIDPO4000BTekVPI w/ HardkeyDPO5000 / DPO5000BTekVPI w/ …KB-02049 What rackmount does my scope use?
Question: What rackmount does my scope use? Answer: Oscilloscope FamilyRackmount 2 Series MSO 2-RK 3 Series MDO RM3 4 Series MSO RM4 5 Series MSO / B RM5 5 Series MSO Low Profile Rack mount standard, optional bench configuration available 020-3180 …KB-01989 What feature does the DPO4BND included?
Question: What feature does the DPO4BND included? Answer: DPO4BND includes the features for the following modules. DPO4AERODPO4AUDIO DPO4AUTODPO4COMPDPO4EMBDDPO4ENETDPO4LMTDPO4PWRDPO4USBDPO4VID Note: Compatibility Issues below: The DPO4BND …KB-01446

