EA-PSI 10000 Series Programmable Power Supplies

The EA-10000 Series programmable DC power supplies bring a host of capabilities and efficiencies to your application. Active power factor correction minimizes waste drawn from your power grid. True autoranging allows the delivery of maximum power along a wider range of voltage and current values while a suite of optional control interfaces enables computer control in near any manufacturing environment.

The EA PS and PSI programmable power supplies range in power from 1500W devices up to 30kW in a single chassis and feature 5″ TFT Gorilla® Glass touchscreen displays for intuitive control and test setup. The power supplies can be paralleled for up to 3.84MW in output power at up to 2000VDC. The PSI Series comes standard with a built-in function generator capable of creating arbitrary waveforms, included test routines for battery test, fuel cell simulation, PV solar array simulation with MPP tracking, and other enhanced capabilities over the PS Series

Power

Up to 30 kW

Voltage

Up to 2000 V

Current

Up to 1000 A

Ea 10000 series

Autoranging Gives Flexibility

EA Elektro-Automatik products have autoranging, which allows the supply or load to operate at max power across a range of voltages and currents, down to 33% of the rated output maximum.

Compare this to traditional power supplies, which can only output their rated power at their max voltage and max current. Applying the maximum voltage to a device under test (DUT) is rare, which means most of the time, that supply is not being used to its full potential.

How does it work? EA sources automatically offer more current at lower voltages (or more voltage at lower currents), allowing the supply to continue outputting the rated power. This allows a single source to address multiple voltage and current combinations that would otherwise require multiple supplies.

Built-In Function Generator

Simplifies Setups Many EA supplies and loads include an integrated function generator that can be used to drive the voltage or current output. All the typical AFG waveforms are available as well as arbitrary capability with sequencing for creating more custom output waveforms. This AFG capability scales with multiple supplies in parallel. The function generator allows the supply to simulate or test complex behaviors like: Simulating a solar cell with accurate open circuit voltage, short circuit current, and maximum power point (MPP) voltage and current. Testing inverter efficiency to CSN EN 50530 standards. Testing LV123, LV124 and LV148 standards for automotive suppliers.

function generator ea 10000 series
Ea 10000 series

Control the way you Control

Using the right control interface simplifies setup and reduces troubleshooting, so the EA-10000 Series supports the AnyBus system allowing for field installable communication options for common industrial interfaces like ProfiNet, CANopen, Modbus-TCP, DeviceNet, EtherCAT, RS-232, and more. These are in addition to standard included interfaces like USB and Ethernet.

Industrial Series for Most Demanding Power Needs

For the highest energy density needs and future-oriented applications, the EA-10000 Industrial Series is available. 6U form factors offer up to 60kW of power, and 19” rack solutions mean you can deliver 300kW of power from only 0.6 m2 of floor space. Combine up to 13 racks for 3.84MW of bidirectional power delivery and recovery. The industrial series are available as a unidirectional power supply (PU), bidirectional power supply (PUB), and regenerative electronic load (PUL).

Learn more about EA Industrial Series

Ea 10000 series
EA water cooling box

Optional Water Cooling available for 4U and 6U models

Industrial environments can be harsh with high ambient temperatures, dust, and other contaminants. In addition, industrial facilities often have to comply with stringent environmental regulations regarding heat and noise emissions. Water-cooled systems can provide stable operation in such conditions, as the cooling efficiency is less affected by the external environment compared to air cooling. Furthermore, water-cooled power supplies can help to meet the standards required by reduced noise levels. Learn more in this video.

  • Efficient Heat Dissipation

  • Reduced Noise and Heat Impact

  • Reliable in Harsh Conditions

Series Power Voltage Current Range Channels
EA-PSI 10000 4U 0–30 kW 0–60 V up to 0–2000 V 0–40 A up to 0–1000 A
Model Power Voltage Current Range
EA PSI 10060 1000 4U 0–30 kW 0–60 V 0–1000 A Get a quote
EA PSI 10080 1000 4U 0–30 kW 0–80 V 0–1000 A Get a quote
EA PSI 10200 420 4U 0–30 kW 0–200 V 0–420 A Get a quote
EA PSI 10360 240 4U 0–30 kW 0–360 V 0–240 A Get a quote
EA PSI 10500 180 4U 0–30 kW 0–500 V 0–180 A Get a quote
EA PSI 10750 120 4U 0–30 kW 0–750 V 0–120 A Get a quote
EA PSI 10920 125 4U 0–30 kW 0–920 V 0–125 A Get a quote
EA PSI 11000 80 4U 0–30 kW 0–80 V 0–80 A Get a quote
EA PSI 11500 60 4U 0–30 kW 0–60 V 0–60 A Get a quote
EA PSI 12000 40 4U 0–30 kW 0–40 V 0–40 A Get a quote
EA-PSI 10000 2U 0–1.5 kW /0–3 kW 0–60 V up to 0–1500 V 0–6 A up to 0–120 A
Model Power Voltage Current Range
EA PSI 10060 120 2U 0–3 kW 0–60 V 0–120 A Get a quote
EA PSI 10060 60 2U 0–1.5 kW 0–60 V 0–60 A Get a quote
EA PSI 10080 120 2U 0–3 kW 0–80 V 0–120 A Get a quote
EA PSI 10080 60 2U 0–1.5 kW 0–80 V 0–60 A Get a quote
EA PSI 10200 25 2U 0–1.5 kW 0–200 V 0–25 A Get a quote
EA PSI 10200 50 2U 0–3 kW 0–200 V 0–50 A Get a quote
EA PSI 10360 15 2U 0–1.5 kW 0–360 V 0–15 A Get a quote
EA PSI 10360 30 2U 0–3 kW 0–360 V 0–30 A Get a quote
EA PSI 10500 10 2U 0–1.5 kW 0–500 V 0–10 A Get a quote
EA PSI 10500 20 2U 0–3 kW 0–500 V 0–20 A Get a quote
EA PSI 10750 06 2U 0–1.5 kW 0–750 V 0–6 A Get a quote
EA PSI 10750 12 2U 0–3 kW 0–750 V 0–12 A Get a quote
EA PSI 11000 10 2U 0–3 kW 0–1000 V 0–10 A Get a quote
EA PSI 11500 06 2U 0–3 kW 0–1500 V 0–6 A Get a quote
EA-PS 9000 1U 0–1.5 kW /0–3 kW 0–80 V up to 0–750 V 0–6 A up to 0–100 A
Model Power Voltage Current Range
EA PS 9080 100 1U 0–3 kW 0–80 V 0–100 A Get a quote
EA PS 9080 50 1U 0–1.5 kW 0–80 V 0–50 A Get a quote
EA PS 9200 25 1U 0–1.5 kW 0–200 V 0–25 A Get a quote
EA PS 9200 50 1U 0–3 kW 0–200 V 0–50 A Get a quote
EA PS 9360 15 1U 0–1.5 kW 0–360 V 0–15 A Get a quote
EA PS 9360 30 1U 0–3 kW 0–360 V 0–30 A Get a quote
EA PS 9500 10 1U 0–1.5 kW 0–500 V 0–10 A Get a quote
EA PS 9500 20 1U 0–3 kW 0–500 V 0–20 A Get a quote
EA PS 9750 06 1U 0–1.5 kW 0–750 V 0–6 A Get a quote
EA PS 9750 12 1U 0–3 kW 0–750 V 0–12 A Get a quote
EA-PS 10000 3U 0–5 kW /0–10 kW /0–15 kW 0–60 V up to 0–2000 V 0–20 A up to 0–510 A
Model Power Voltage Current Range
EA PS 10060 170 3U 0–5 kW 0–60 V 0–170 A Get a quote
EA PS 10060 340 3U 0–10 kW 0–60 V 0–340 A Get a quote
EA PS 10060 510 3U 0–15 kW 0–60 V 0–510 A Get a quote
EA PS 10080 170 3U 0–5 kW 0–80 V 0–170 A Get a quote
EA PS 10080 340 3U 0–10 kW 0–80 V 0–340 A Get a quote
EA PS 10080 510 3U 0–15 kW 0–80 V 0–510 A Get a quote
EA PS 10200 140 3U 0–10 kW 0–200 V 0–140 A Get a quote
EA PS 10200 210 3U 0–15 kW 0–200 V 0–210 A Get a quote
EA PS 10200 70 3U 0–5 kW 0–200 V 0–70 A Get a quote
EA PS 10360 120 3U 0–15 kW 0–360 V 0–120 A Get a quote
EA PS 10360 40 3U 0–5 kW 0–360 V 0–40 A Get a quote
EA PS 10360 80 3U 0–10 kW 0–360 V 0–80 A Get a quote
EA PS 10500 30 3U 0–5 kW 0–500 V 0–300 A Get a quote
EA PS 10500 60 3U 0–10 kW 0–500 V 0–60 A Get a quote
EA PS 10500 90 3U 0–15 kW 0–500 V 0–90 A Get a quote
EA PS 10750 20 3U 0–5 kW 0–750 V 0–20 A Get a quote
EA PS 10750 40 3U 0–10 kW 0–750 V 0–40 A Get a quote
EA PS 10750 60 3U 0–15 kW 0–750 V 0–60 A Get a quote
EA PS 11000 30 3U 0–10 kW 0–1000 V 0–30 A Get a quote
EA PS 11000 40 3U 0–15 kW 0–1000 V 0–40 A Get a quote
EA PS 11500 20 3U 0–10 kW 0–1500 V 0–20 A Get a quote
EA PS 11500 30 3U 0–15 kW 0–1500 V 0–30 A Get a quote
EA PS 12000 20 3U 0–15 kW 0–2000 V 0–20 A Get a quote
EA-PSI 10000 3U 0–5 kW /0–10 kW /0–15 kW 0–60 V up to 0–2000 V 0–20 A up to 0–510 A
Model Power Voltage Current Range
EA PSI 10060 170 3U 0–5 kW 0–60 V 0–170 A Get a quote
EA PSI 10060 340 3U 0–10 kW 0–60 V 0–340 A Get a quote
EA PSI 10060 510 3U 0–15 kW 0–60 V 0–510 A Get a quote
EA PSI 10080 170 3U 0–5 kW 0–80 V 0–170 A Get a quote
EA PSI 10080 340 3U 0–10 kW 0–80 V 0–340 A Get a quote
EA PSI 10080 510 3U 0–15 kW 0–80 V 0–510 A Get a quote
EA PSI 10200 140 3U 0–10 kW 0–200 V 0–140 A Get a quote
EA PSI 10200 210 3U 0–15 kW 0–200 V 0–210 A Get a quote
EA PSI 10200 70 3U 0–5 kW 0–200 V 0–70 A Get a quote
EA PSI 10360 120 3U 0–15 kW 0–360 V 0–120 A Get a quote
EA PSI 10360 40 3U 0–5 kW 0–360 V 0–40 A Get a quote
EA PSI 10360 80 3U 0–10 kW 0–360 V 0–80 A Get a quote
EA PSI 10500 30 3U 0–5 kW 0–500 V 0–30 A Get a quote
EA PSI 10500 60 3U 0–10 kW 0–500 V 0–60 A Get a quote
EA PSI 10500 90 3U 0–15 kW 0–500 V 0–90 A Get a quote
EA PSI 10750 20 3U 0–5 kW 0–750 V 0–20 A Get a quote
EA PSI 10750 40 3U 0–10 kW 0–750 V 0–40 A Get a quote
EA PSI 10750 60 3U 0–15 kW 0–750 V 0–60 A Get a quote
EA PSI 10920 20 3U 0–5 kW 0–920 V 0–20 A Get a quote
EA PSI 10920 40 3U 0–10 kW 0–920 V 0–40 A Get a quote
EA PSI 10920 60 3U 0–15 kW 0–920 V 0–60 A Get a quote
EA PSI 11000 30 3U 0–10 kW 0–1000 V 0–30 A Get a quote
EA PSI 11000 40 3U 0–15 kW 0–1000 V 0–40 A Get a quote
EA PSI 11500 20 3U 0–10 kW 0–1500 V 0–20 A Get a quote
EA PSI 11500 30 3U 0–15 kW 0–1500 V 0–30 A Get a quote
EA PSI 12000 20 3U 0–15 kW 0–2000 V 0–20 A Get a quote
EA-PS 10000 4U 0–30 kW 0–60 V up to 0–2000 V 0–40 A up to 0–1000 A
Model Power Voltage Current Range
EA PS 10060 1000 4U 0–30 kW 0–60 V 0–1000 A Get a quote
EA PS 10080 1000 4U 0–30 kW 0–80 V 0–1000 A Get a quote
EA PS 10200 420 4U 0–30 kW 0–200 V 0–420 A Get a quote
EA PS 10360 240 4U 0–30 kW 0–360 V 0–240 A Get a quote
EA PS 10500 180 4U 0–30 kW 0–500 V 0–180 A Get a quote
EA PS 10750 120 4U 0–30 kW 0–750 V 0–120 A Get a quote
EA PS 10920 125 4U 0–30 kW 0–920 V 0–125A Get a quote
EA PS 11000 80 4U 0–30 kW 0–1000 V 0–80 A Get a quote
EA PS 11500 60 4U 0–30 kW 0–1500 V 0–60 A Get a quote
EA PS 12000 40 4U 0–30 kW 0–2000 V 0–40 A Get a quote
EA-PS 10000 2U 0–1.5 kW /0–3 kW 0–60 V up to 0–1500 V 0–6 A up to 0–120 A
Model Power Voltage Current Range
EA PS 10060 120 2U 0–3 kW 0–60 V 0–120 A Get a quote
EA PS 10060 60 2U 0–1.5 kW 0–60 V 0–60 A Get a quote
EA PS 10080 120 2U 0–3 kW 0–80 V 0–120 A Get a quote
EA PS 10080 60 2U 0–1.5 kW 0–80 V 0–60 A Get a quote
EA PS 10200 25 2U 0–1.5 kW 0–200 V 0–25 A Get a quote
EA PS 10200 50 2U 0–3 kW 0–200 V 0–50 A Get a quote
EA PS 10360 15 2U 0–1.5 kW 0–360 V 0–15 A Get a quote
EA PS 10360 30 2U 0–3 kW 0–360 V 0–30 A Get a quote
EA PS 10500 10 2U 0–1.5 kW 0–500 V 0–10 A Get a quote
EA PS 10500 20 2U 0–3 kW 0–500 V 0–20 A Get a quote
EA PS 10750 06 2U 0–1.5 kW 0–750 V 0–6 A Get a quote
EA PS 10750 12 2U 0–3 kW 0–750 V 0–12 A Get a quote
EA PS 11000 10 2U 0–3 kW 0–1000 V 0–10 A Get a quote
EA PS 11500 06 2U 0–3 kW 0–1500 V 0–6 A Get a quote
Model Power Voltage Current Range Channels List Price Configure And Quote
EA-PSI 10000 4U 0–30 kW 0–60 V up to 0–2000 V 0–40 A up to 0–1000 A - Configure & Quote
EA-PSI 10000 2U 0–1.5 kW /0–3 kW 0–60 V up to 0–1500 V 0–6 A up to 0–120 A - Configure & Quote
EA-PS 9000 1U 0–1.5 kW /0–3 kW 0–80 V up to 0–750 V 0–6 A up to 0–100 A - Configure & Quote
EA-PS 10000 3U 0–5 kW /0–10 kW /0–15 kW 0–60 V up to 0–2000 V 0–20 A up to 0–510 A - Configure & Quote
EA-PSI 10000 3U 0–5 kW /0–10 kW /0–15 kW 0–60 V up to 0–2000 V 0–20 A up to 0–510 A - Configure & Quote
EA-PS 10000 4U 0–30 kW 0–60 V up to 0–2000 V 0–40 A up to 0–1000 A - Configure & Quote
EA-PS 10000 2U 0–1.5 kW /0–3 kW 0–60 V up to 0–1500 V 0–6 A up to 0–120 A - Configure & Quote