EA-PUB/PUL/PU Industrial Power Units

EA-10000 Industrial Series sets a new benchmark in power density—delivering up to 300 kW in a single rack with a sleek, display-free design. Offering a wide range of programmable DC power supplies, bidirectional units, and regenerative loads, it ensures high safety, >96% energy recovery, and unified firmware for seamless integration and efficient multi-unit system development.

Industrial series are available for these power unit types:

  • Power Unit Bidirectional (PUB) - bidirectional power supply
  • Power Unit Load (PUL) - regenerative electronic load
  • Power Unit (PU) - conventional power supply
Power

Up to 60 kW

Voltage

Up to 2000 V

Current

Up to1000 A

EA-10000 Industrial series

Powerful, Bidirectional and Regenerative

Powerful performance

  • 6U Power with 60 kW including 21 models
  • 4U Power with 30 kW including 29 models
  • Large selection of 50 models for special applications
  • This includes Programmable DC power supplies, Programmable bidirectional DC power supplies, and Regenerative electronic loads

Powerful rack performance

  • A 19“ rack with 42 U for a system with 300 kW
  • One unit with up to 13 racks with 64 units of 60 kW each
  • For high power applications up to 3.84 MW

Powerful efficiency

  • Fewer units for a high-power system
  • Less rack space required
  • Less operating costs
Powerful, Bidirectional and Regenerative

Smart Features, Scalable Options, and Peak Efficiency

The High-tech Features:

  • DC input / output with autoranging
  • Digital (FPGA) controlled DC input / output U – I – P – R
  • Latest SiC technology
  • LED‘s in the front to indicate the status of the device
  • AC mains input with extended range (380 V – 480 V, 3ph AC)
  • Built-in interfaces: Ethernet, USB, Analog

Optionally available:

  • Stainless steel water cooling
  • Optional Interfaces: CAN, CANopen, EtherCAT, RS232, Profibus, Profinet, Modbus, Ethernet

 

 

 

For efficiency and sustainability:

  • Master-Auxiliary-Bus and Share-Bus
    To make a multi-device system behave like a single device
  • Energy recovery up to over 96 %.
    Regenerative load operation with energy recovery into the grid
  • Autoranging
    The principle of automatic switching
  • Function generator and more
    Ramp function, arbitrary generator, LUT, integrated PV characteristic curve
  • Variety of devices for every requirement
    21 models in 60 kW series and 29 models in 30 kW series

For Future-Oriented Applications:

Advanced power applications

  • Tests of batteries and fuel cells
  • Simulations of batteries and solar systems
  • The complete discharge of batteries for recycling
  • The power supply of electrolysis plants
  • Sustainable power electronics for aviation applications
  • For use in ATE systems and automated process control systems
For future-oriented applications:
EA water cooling box

Optional Water Cooling available for 4U and 6U models

Industrial environments can be harsh with high ambient temperatures, dust, and other contaminants. In addition, industrial facilities often have to comply with stringent environmental regulations regarding heat and noise emissions. Water-cooled systems can provide stable operation in such conditions, as the cooling efficiency is less affected by the external environment compared to air cooling. Furthermore, water-cooled power supplies can help to meet the standards required by reduced noise levels. Learn more in this video.

  • Efficient Heat Dissipation

  • Reduced Noise and Heat Impact

  • Reliable in Harsh Conditions

Series Power Voltage Current Range Channels
EA-PUL 10000 6U 0–60 kW 0–360 V up to 0–2000 V 0–80 A up to 0–480 A
Model Power Voltage Current Range
EA PUL 10360 480 6U 0–60 kW 0–360 V 0–480 A Get a quote
EA PUL 10500 360 6U 0–60 kW 0–500 V 0–360 A Get a quote
EA PUL 10750 240 6U 0–60 kW 0–750 V 0–240 A Get a quote
EA PUL 10920 250 6U 0–60 kW 0–920 V 0–250 A Get a quote
EA PUL 11000 160 6U 0–60 kW 0–1000 V 0–160 A Get a quote
EA PUL 11500 120 6U 0–60 kW 0–1500 V 0–120 A Get a quote
EA PUL 12000 80 6U 0–60 kW 0–2000 V 0–80 A Get a quote
EA-PUB 10000 6U 0–60 kW 0–360 V up to 0–2000 V 0–80 A up to 0–480 A
Model Power Voltage Current Range
EA PUB 10360 480 6U 0–60 kW 0–360 V 0–480 A Get a quote
EA PUB 10500 360 6U 0–60 kW 0–500 V 0–360 A Get a quote
EA PUB 10750 240 6U 0–60 kW 0–750 V 0–240 A Get a quote
EA PUB 10920 250 6U 0–60 kW 0–920 V 0–250 A Get a quote
EA PUB 11000 160 6U 0–60 kW 0–1000 V 0–160 A Get a quote
EA PUB 11500 120 6U 0–60 kW 0–1500 V 0–120 A Get a quote
EA PUB 12000 80 6U 0–60 kW 0–2000 V 0–80 A Get a quote
EA-PU 10000 4U 0–30 kW 0–60 V up to 0–2000 V 0–40 A up to 0–1000 A
Model Power Voltage Current Range
EA PU 10060 1000 4U 0–30 kW 0–60 V 0–1000 A Get a quote
EA PU 10080 1000 4U 0–30 kW 0–80 V 0–1000 A Get a quote
EA PU 10200 420 4U 0–30 kW 0–200 V 0–420 A Get a quote
EA PU 10360 240 4U 0–30 kW 0–360 V 0–240 A Get a quote
EA PU 10500 180 4U 0–30 kW 0–500 V 0–180 A Get a quote
EA PU 10750 120 4U 0–30 kW 0–750 V 0–120 A Get a quote
EA PU 10920 125 4U 0–30 kW 0–920 V 0–125 A Get a quote
EA PU 11000 80 4U 0–30 kW 0–1000 V 0–80 A Get a quote
EA PU 11500 60 4U 0–30 kW 0–1500 V 0–60 A Get a quote
EA PU 12000 40 4U 0–30 kW 0–2000 V 0–40 A Get a quote
EA-PU 10000 6U 0–60 kW 0–360 V up to 0–2000 V 0–80 A up to 0–480 A
Model Power Voltage Current Range
EA PU 10360 480 6U 0–60 kW 0–360 V 0–480 A Get a quote
EA PU 10500 360 6U 0–60 kW 0–500 V 0–360 A Get a quote
EA PU 10750 240 6U 0–60 kW 0–750 V 0–240 A Get a quote
EA PU 10920 250 6U 0–60 kW 0–920 V 0–250 A Get a quote
EA PU 11000 160 6U 0–60 kW 0–1000 V 0–160 A Get a quote
EA PU 11500 120 6U 0–60 kW 0–1500 V 0–120 A Get a quote
EA PU 12000 80 6U 0–60 kW 0–2000 V 0–80 A Get a quote
EA-PUB 10000 4U 0–30 kW 0–60 V up to 0–1500 V 0–40 A up to 0–1000 A
Model Power Voltage Current Range
EA PUB 10060 1000 4U 0–30 kW 0–60 V 0–1000 A Get a quote
EA PUB 10080 1000 4U 0–30 kW 0–80 V 0–1000 A Get a quote
EA PUB 10200 420 4U 0–30 kW 0–200 V 0–420 A Get a quote
EA PUB 10360 240 4U 0–30 kW 0–360 V 0–240 A Get a quote
EA PUB 10500 180 4U 0–30 kW 0–500 V 0–180 A Get a quote
EA PUB 10750 120 4U 0–30 kW 0–750 V 0–120 A Get a quote
EA PUB 10920 125 4U 0–30 kW 0–920 V 0–125 A Get a quote
EA PUB 11000 80 4U 0–30 kW 0–1000 V 0–80 A Get a quote
EA PUB 11500 60 4U 0–30 kW 0–1500 V 0–60 A Get a quote
EA-PUL 10000 4U 0–30 kW 0–60 V up to 0–2000 V 0–40 A up to 0–1000 A
Model Power Voltage Current Range
EA PUL 10060 1000 4U 0–30 kW 0–60 V 0–1000 A Get a quote
EA PUL 10080 1000 4U 0–30 kW 0–80 V 0–1000 A Get a quote
EA PUL 10200 420 4U 0–30 kW 0–200 V 0–420 A Get a quote
EA PUL 10360 240 4U 0–30 kW 0–360 V 0–240 A Get a quote
EA PUL 10500 180 4U 0–30 kW 0–500 V 0–180 A Get a quote
EA PUL 10750 120 4U 0–30 kW 0–750 V 0–120 A Get a quote
EA PUL 10920 125 4U 0–30 kW 0–920 V 0–125 A Get a quote
EA PUL 11000 80 4U 0–30 kW 0–1000 V 0–80 A Get a quote
EA PUL 11500 60 4U 0–30 kW 0–1500 V 0–60 A Get a quote
EA PUL 12000 40 4U 0–30 kW 0–2000 V 0–40 A Get a quote
Series Power Voltage Current Range Channels
EA-PUL 10000 6U 0–60 kW 0–360 V up to 0–2000 V 0–80 A up to 0–480 A
Model Power Voltage Current Range
EA PUL 10360 480 6U 0–60 kW 0–360 V 0–480 A Get a quote
EA PUL 10500 360 6U 0–60 kW 0–500 V 0–360 A Get a quote
EA PUL 10750 240 6U 0–60 kW 0–750 V 0–240 A Get a quote
EA PUL 10920 250 6U 0–60 kW 0–920 V 0–250 A Get a quote
EA PUL 11000 160 6U 0–60 kW 0–1000 V 0–160 A Get a quote
EA PUL 11500 120 6U 0–60 kW 0–1500 V 0–120 A Get a quote
EA PUL 12000 80 6U 0–60 kW 0–2000 V 0–80 A Get a quote
EA-PUB 10000 6U 0–60 kW 0–360 V up to 0–2000 V 0–80 A up to 0–480 A
Model Power Voltage Current Range
EA PUB 10360 480 6U 0–60 kW 0–360 V 0–480 A Get a quote
EA PUB 10500 360 6U 0–60 kW 0–500 V 0–360 A Get a quote
EA PUB 10750 240 6U 0–60 kW 0–750 V 0–240 A Get a quote
EA PUB 10920 250 6U 0–60 kW 0–920 V 0–250 A Get a quote
EA PUB 11000 160 6U 0–60 kW 0–1000 V 0–160 A Get a quote
EA PUB 11500 120 6U 0–60 kW 0–1500 V 0–120 A Get a quote
EA PUB 12000 80 6U 0–60 kW 0–2000 V 0–80 A Get a quote
EA-PU 10000 4U 0–30 kW 0–60 V up to 0–2000 V 0–40 A up to 0–1000 A
Model Power Voltage Current Range
EA PU 10060 1000 4U 0–30 kW 0–60 V 0–1000 A Get a quote
EA PU 10080 1000 4U 0–30 kW 0–80 V 0–1000 A Get a quote
EA PU 10200 420 4U 0–30 kW 0–200 V 0–420 A Get a quote
EA PU 10360 240 4U 0–30 kW 0–360 V 0–240 A Get a quote
EA PU 10500 180 4U 0–30 kW 0–500 V 0–180 A Get a quote
EA PU 10750 120 4U 0–30 kW 0–750 V 0–120 A Get a quote
EA PU 10920 125 4U 0–30 kW 0–920 V 0–125 A Get a quote
EA PU 11000 80 4U 0–30 kW 0–1000 V 0–80 A Get a quote
EA PU 11500 60 4U 0–30 kW 0–1500 V 0–60 A Get a quote
EA PU 12000 40 4U 0–30 kW 0–2000 V 0–40 A Get a quote
EA-PU 10000 6U 0–60 kW 0–360 V up to 0–2000 V 0–80 A up to 0–480 A
Model Power Voltage Current Range
EA PU 10360 480 6U 0–60 kW 0–360 V 0–480 A Get a quote
EA PU 10500 360 6U 0–60 kW 0–500 V 0–360 A Get a quote
EA PU 10750 240 6U 0–60 kW 0–750 V 0–240 A Get a quote
EA PU 10920 250 6U 0–60 kW 0–920 V 0–250 A Get a quote
EA PU 11000 160 6U 0–60 kW 0–1000 V 0–160 A Get a quote
EA PU 11500 120 6U 0–60 kW 0–1500 V 0–120 A Get a quote
EA PU 12000 80 6U 0–60 kW 0–2000 V 0–80 A Get a quote
EA-PUB 10000 4U 0–30 kW 0–60 V up to 0–1500 V 0–40 A up to 0–1000 A
Model Power Voltage Current Range
EA PUB 10060 1000 4U 0–30 kW 0–60 V 0–1000 A Get a quote
EA PUB 10080 1000 4U 0–30 kW 0–80 V 0–1000 A Get a quote
EA PUB 10200 420 4U 0–30 kW 0–200 V 0–420 A Get a quote
EA PUB 10360 240 4U 0–30 kW 0–360 V 0–240 A Get a quote
EA PUB 10500 180 4U 0–30 kW 0–500 V 0–180 A Get a quote
EA PUB 10750 120 4U 0–30 kW 0–750 V 0–120 A Get a quote
EA PUB 10920 125 4U 0–30 kW 0–920 V 0–125 A Get a quote
EA PUB 11000 80 4U 0–30 kW 0–1000 V 0–80 A Get a quote
EA PUB 11500 60 4U 0–30 kW 0–1500 V 0–60 A Get a quote
EA-PUL 10000 4U 0–30 kW 0–60 V up to 0–2000 V 0–40 A up to 0–1000 A
Model Power Voltage Current Range
EA PUL 10060 1000 4U 0–30 kW 0–60 V 0–1000 A Get a quote
EA PUL 10080 1000 4U 0–30 kW 0–80 V 0–1000 A Get a quote
EA PUL 10200 420 4U 0–30 kW 0–200 V 0–420 A Get a quote
EA PUL 10360 240 4U 0–30 kW 0–360 V 0–240 A Get a quote
EA PUL 10500 180 4U 0–30 kW 0–500 V 0–180 A Get a quote
EA PUL 10750 120 4U 0–30 kW 0–750 V 0–120 A Get a quote
EA PUL 10920 125 4U 0–30 kW 0–920 V 0–125 A Get a quote
EA PUL 11000 80 4U 0–30 kW 0–1000 V 0–80 A Get a quote
EA PUL 11500 60 4U 0–30 kW 0–1500 V 0–60 A Get a quote
EA PUL 12000 40 4U 0–30 kW 0–2000 V 0–40 A Get a quote