Contact us
Contact us
Live Chat with Tek representatives. Available 6:00 AM - 4:30 PM PST.
Download
Download
Download Manuals, Datasheets, Software and more:
Product Support and Downloads
Welcome to Tektronix Product Support
While we’re happy to “talk tech” with you all day long, we know you’re in a hurry. So we’ve made it easy for you to download manuals, datasheets and software for all our current products, and many discontinued products as well. Just tell us which product you’re using, and we’ll show you everything we have.
The product model you have chosen is currently available for purchase. The following support information is available.
-
Datasheet Literature Number: ReleaseDate Mixed Domain Oscilloscopes
Customizable and fully upgradeable 6-in-1 integrated oscilloscope with synchronized insights into analog, digital, and RF signals48W-60277-10 KickStart Instrument Control Software Datasheet
KickStart Software simplifies what you need to know about your instrument so that in just minutes you can take the instrument out of the box and get real data on your device. KickStart Software enables quick test setup and data visualization when …1KW-60965-6 MDO4000 Series Mixed Domain Oscilloscopes (Replaced by MDO4000B)
Replaced by the MDO4000B -- Introducing the world’s first and only oscilloscope with a built-in spectrum analyzer. For the first time ever, you can capture time-correlated analog, digital, and RF signals for a complete system view of your device. See …48W-26875-4
-
Manuals Manual Type Part Number: ReleaseDate MDO4000C Series
OscilloscopeService 077117901 SignalVu-PC
Vector Signal Analysis softwareUser 077102417 MDO4000C Series
Mixed Domain OscilloscopePerformance Verification 077117801 MDO4000C, MDO4000B, MDO4000, MSO4000B, DPO4000B, and MDO3000 Series
Digital OscilloscopesProgrammer 077051009 MDO4000C Series
OscilloscopeUser 077116702 MDO4000C Series
Oscilloscope User ManualPrimary User 077116701 MDO4000C Series
Oscilloscope User ManualPrimary User 077116700 MDO4000C Series Oscilloscope
Security and Declassification InstructionsDeclassification 077118000
-
Technical Documents Document Type ReleaseDate Tektronix Probe Selection Guide
Tektronix probes ensure the highest signal fidelity possible from your device-under-test to your oscilloscope. With over 100 probe choices available, all perfectly matched to our industry-leading oscilloscopes, you can find the probe you need for …Product Selector Guide Advanced Radar Analysis: Tools for Measuring Modern Radar Application Note
With today's rapid advances in radar technology, developing and manufacturing highly specialized and innovative electronic products to detect radar signals takes leading-edge technology and tools. Tektronix innovative test equipment reduces testing …Application Note Working Remotely with Tektronix Oscilloscopes
Most modern Tektronix oscilloscopes support one or more ways of working remotely. These methods include simple file-sharing and offline analysis, control using PC software, custom programming in Python or other languages, and remote access over a …Technical Brief Serial Support Using Tektronix Oscilloscopes and Optional Software
Tektronix oscilloscopes offer a portfolio of optional analysis capabilities to simplify serial bus debug or compliance verification. This selection matrix shows which serial standards are supported by each of the oscilloscope series.Selection Guide MDO4000 Series vs. Regular Oscilloscope FFTs
Examine the MDO4000 Series vs a regular oscilloscope FFTs.Competitive Introduction to Video Measurements
In this application note, we demonstrate using a MSO/DPO5000, MDO/MSO/DPO4000 and MDO/MSO/DPO3000 Series Oscilloscope to make a variety of video measurements that are common in standard and high definition systems.Application Note Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope
Problems with setup and hold timing are among the most challenging to identify. Mixed signal oscilloscopes (MSOs) are able to capture both analog and digital representations of signals, making them well-suited for identifying digital timing problems …Application Note Oscilloscope Selection Guide
From basic signal-checking to high-performance analysis, this selection guide gives an overview of the complete range of oscilloscopes from Tektronix. Comparison tables give high-level specifications and features, and indicate the major differences …Selection Guide Wi-Fi: Overview of the 802.11 Physical Layer and Transmitter Measurements
Wi-Fi is a technology that allows many electronic devices to exchange data or connect to the internet wirelessly using radio waves. The Wi-Fi Alliance defines Wi-Fi devices as any "Wireless Local Area Network (WLAN) products that are based on the …Primer Wave Inspector® Navigation and Search: Simplifying Waveform Analysis
Modern digital oscilloscopes can capture massive amounts of data which must then be analyzed. Discover how the Tektronix Wave Inspector® navigation and search capability gives you the tools to extract the answers you need fast and efficiently.Application Note Keysight N9320B Spectrum Analyzer vs MDO4000C Comparison
Side-by-side comparison on important specifications and features like correlating RF to other system signals and exceptionally wide capture bandwidth.Competitive Keysight N9322C Spectrum Analyzer vs MDO4000C Series Comparison
Side-by-side comparison on important specifications and features like correlating RF to other system signals and exceptionally wide capture bandwidth.Competitive Keysight 4000X vs MDO4000C Competitive Comparison
Side-by-side comparison on important features like serial triggering and decode, waveform navigation and search, waveform capture rate, digital debug with MSO, and more.Competitive Keysight N9000A CXA Spectrum Analyers vs MDO4000C Series Comparison
Side-by-side comparison on important specifications and features like correlating RF to other system signals and exceptionally wide capture bandwidth.Competitive Fundamentals of the MDO4000 Series Mixed Domain Oscilloscope
Today’s design engineers often must debug complex devices, with integrated analog and digital signals, serial buses, and now RF signals for wireless communication. In this application note, learn how a Mixed Domain Oscilloscope (MDO) offers time …Application Note Tektronix MDO4000C Series Oscilloscopes
This demonstration guide takes you through a series of step-by-step demonstrations on how the MDO4000C Series oscilloscope helps simplify the debug of mixed signal designs with its powerful functionality and integrated test instruments. This …How-to Guide Testing a New Switch Mode Power Supply Design Poster
Get a quick overview of the key measurements for verifying a new switch mode power supply (SMPS) design. This poster shows key measurements, from verifying your prototype during initial startup, to optimizing switching loss and magnetic losses, to …Poster 4 Series MSO vs MDO4000C
This fact sheet compares important specifications and features of the Tektronix 4 Series MSO Mixed Signal Oscilloscope to those of the Tektronix MDO4000 Series Oscilloscopes.Fact Sheet Accurate Measurements Matter
MDO4000C Series measurements are taken on actual acquisition data - providing as much data to the measurement algorithms as possible. The Keysight 4000 X-Series uses the lower resolution display data, which can produce measurements that are …Fact Sheet Automotive Solutions Brochure
The pace of change in automotive electronics has never been faster, resulting in safer, more efficient, and more connected vehicles. Technologies such as high-speed data communications, wireless communications, radar, and power supplies underpin …Brochure Power Supply Measurement & Analysis with Bench Oscilloscopes
Today’s power supplies are driving to a level of efficiency never seen before, requiring design engineers to perform specialized power measurements that are time-consuming and complex. Learn how using a Tektronix Bench Oscilloscopes provides fast …Application Note Power Supply Measurement and Analysis Primer
A power supply is a component, subsystem, or system that converts electrical power from one form to another; commonly from alternating current (AC) utility power to direct current (DC) power. The proper operation of electronic devices ranging from …Primer Practical EMI Troubleshooting
After failing an EMI compliance test, where do you start? This application note gives guidance on connecting the information in your test report to a source of radiated emissions. It provides information that applies to any spectrum analyzer -- such …Application Note Secrets of MDO Performance
Learn how:The MDO4000 Series are able to leverage oscilloscope acquisition technology to achieve spectral fidelity on par with entry level spectrum analyzers.The design techniques used in the MDO4000 Series allow them to achieve spectral fidelity far …Whitepaper Capacitance and Inductance Measurements Using an Oscilloscope and a Function Generator
Most labs have an ample supply of DMM's for measuring DC resistance, but when it comes to measuring inductance, capacitance and impedance, it is not always easy to find an LCR meter. LCR meters operate …Application Note Replicating Real World Signals with an Arbitrary/Function Generator
Learn how to simulate sensor and bus signals on an arbitrary waveform generator. Find out how to capture signals using an oscilloscope, edit them using PC software, and play them back on an arbitrary/function generator.Application Note Debugging Serial Buses in Embedded System Designs
Learn the basics of the hardware protocols of the most common serial buses, such as I2C, SPI , USB, RS-232/422/485/UART, CAN, CAN FD, LIN, FlexRay, Ethernet, and I2S/LJ/RJ/TDM. Find out how to use the protocol trigger, decode and search capabilities …Application Note MDO4000C Series vs. Rohde & Schwarz FSL Spectrum Analyzer Comparison
This fact sheet compares specifications and features of the MDO4000 Series to the Rohde & Schwarz FSL Spectrum AnalyzerCompetitive MDO Signal Path Teardown Poster
MDO4000 and MDO3000 Mixed Domain Oscilloscopes deliver uncompromised oscilloscope performance combined with spectrum analyzer performance on par with standalone spectrum analyzers. But how do they do it? The answer lies in Tektronix’ custom ASICs, a …Poster MDO4000C and MDO3000 Series Comparison Fact Sheet
This fact sheet compares features and specifications of MDO4000C and MDO3000 Series mixed domain oscillscopes.Selection Guide MDO4000C Series vs. Rohde & Schwarz FSV Spectrum Analyzer Comparison
This fact sheet compares the specifications and features of the MDO4000 Series to the Rohde & Schwarz FSV Spectrum AnalyzerCompetitive MDO How it Works
Look inside a Mixed Domain Oscilloscope to see how it acheives its spectrum analyzer performance, including high dynamic range and exceptionally high capture bandwidth with dedicated hardware and algorithms.Technical Brief Measuring Wireless Power Charging Systems for Portable Electronics
This application note shows methods for testing a Qi wireless charging system. The device under test uses the Qi interface standard, developed by the Wireless Power Consortium. The application note explains how to use a mixed domain oscilloscope …Application Note How to Minimize Probe Loading with Low Capacitance Probes
Probing a circuit always has some impact on signals. Probe loading changes the signal being probed and can cause measurement problems or can even cause a circuit to perform differently. Reducing capacitive loading can help minimize these effects. In …Application Note How to Use a Mixed Signal Oscilloscope to Test Digital Circuits
Learn how to set up a mixed signal oscilloscope and how use it in several applications including: triggering on pulse width violations, combining analog and digital waveforms to capture crosstalk, troubleshooting setup/hold violations, and checking …Application Note SOLUTIONS FOR SCIENTIFIC AND ENGINEERING RESEARCH
Brochure MDO4000C Series vs. Rohde & Schwarz FSC Spectrum Analyzer Comparison
This fact sheet compares specifations and features of the MDO4000 Series to the Rohde & Schwarz FSC Spectrum AnalyzerCompetitive
-
Software Document Type Part Number: ReleaseDate Tektronix Openchoice Desktop Application TDSPCS1 - V2.8
The Tektronix OpenChoice Desktop free application lets you capture oscilloscope screen images, waveform data, and settings from a Microsoft Windows computer. After installing the software, refer to the section “Connecting to a PC” in your …Utility 066093915 KickStart Instrument Control Software Version 2.4.0 (Windows 10, 8, 7 compatible)
"KickStart Software for the PC enables quick test setup and data visualization when using one or more instruments. Key Features • Save time by automating data collection of millions of …Application KICKSTART-2.4.0 ARBEXPRESS WAVEFORM CREATION AND EDITING SW, V3.6
ArbExpress is a waveform creation and editing tool for Tektronix AWG and AFG instruments. It provides an easy to use and efficient way to create and edit waveforms, transfer waveforms to and from Arbitrary Waveform Generators (AWG), and …Application 066146106 KickStart Instrument Control Software Version 2.3.0 (Windows 10, 8, 7 compatible)
KickStart Software for the PC enables quick test setup and data visualization when using one or more instruments. Key Features: Save time by automating data collection of millions of readings. Set up a multi-instrument test with the ability to …Application KICKSTART-2.3.0 ARBEXPRESS WAVEFORM CREATION AND EDITING SW, V3.5
ArbExpress is a waveform creation and editing tool for Tektronix AWG and AFG instruments. It provides an easy to use and efficient way to create and edit waveforms, transfer waveforms to and from Arbitrary Waveform Generators (AWG), and …Application 066146105 TEKVISA Connectivity Software - V4.2.0
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093812 DPO2000, MSO2000, DPO3000 and DPO4000, MSO3000 and MSO4000, MDO3000 and MDO4000 and MDO3 IVI Driver - V1.5
The Tektronix MSO/DPO2000, MDO/MSO/DPO3000, MDO/MSO/DPO4000 and MDO3 IVI Driver is an IVI class-compliant driver. It complies with Scope Class specifications (IVI-4.1) as defined by the IVI foundation. An IVI class-compliant specific driver for an …Driver 066133104 SignalVu-PC Vector Signal Analysis Software - V3.23.0022
SignalVu-PC VSA software brings the analysis engine of the Tektronix Real-Time Signal Analyzer (RTSA) to your computer, enabling you to analyze live signals from RSA306, RSA500, RSA600, RSA7100A Spectrum Analyzers and MDO4000B/C Series oscilloscopes …Application 066143422 SignalVu-PC Vector Signal Analysis Software - Release Candidate - V3.17.0013
SignalVu-PC VSA software brings the analysis engine of the Tektronix Real-Time Signal Analyzer (RTSA) to your computer, enabling you to analyze live signals from RSA306, RSA500, RSA600, RSA7100A Spectrum Analyzers and MDO4000B/C Series oscilloscopes …Application 066143420 SignalVu-PC Vector Signal Analysis Software - V3.16.0014
SignalVu-PC VSA software brings the analysis engine of the Tektronix Real-Time Signal Analyzer (RTSA) to your computer, enabling you to analyze live signals from RSA306, RSA500, RSA600, RSA7100A Spectrum Analyzers and MDO4000B/C Series oscilloscopes …Application 066143419 MDO4000C FIRMWARE RELEASE - v1.10
MDO4000C firmware updateFirmware 066179905 TEKVISA CONNECTIVITY SOFTWARE - V4.1.1
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093811 MDO4000C FIRMWARE V1.04
This firmware is for all MDO4000C Series oscilloscopes.Firmware 066179902 Tektronix Openchoice Desktop Application TDSPCS1 - v2.6
The Tektronix OpenChoice Desktop free application lets you capture oscilloscope screen images, waveform data, and settings from a Microsoft Windows computer. After installing the software, refer to the section “Connecting to a PC” in your …Utility 066093914 ARBEXPRESS WAVEFORM CREATION AND EDITING SW, V3.4
ArbExpress is a waveform creation and editing tool for Tektronix AWG and AFG instruments. It provides an easy to use and efficient way to create and edit waveforms, transfer waveforms to and from Arbitrary Waveform Generators (AWG), and …Application 066146104
-
FAQS FAQ ID Why do I see 16 flat lines for the MSO digital logic inputs when the same signals are displayed properly on the analog channels and all channels are setup for valid trigger threshold levels?
A common mistake for some, we first recommend verifing that the front panel MSO digital probe is properly connected by squeezing the probe's side latch buttons to un-plug, remove the probe then re-insert the probe label side up into the front panel …60251 Why does my MDO4000C Series scope cause my USB flash drive to pop up with a scan and fix message on my PC?
The MDO4000C products have a new Linux kernel. The security settings of this kernel require that any USB flash drive that is removed without unmounting get tagged as a suspicious device. This can be seen when a drive is written to on the scope …72166 Why isn’t the TPP1000 (Tektronix Passive Probe 1GHz) compatible with my scope?
Short answer is that if your scope doesn’t have the notched key that allows the probe to connect, then the TPP probe requires a different termination resistance than what your scope can provide. Long answer is that traditionally, passive probes …467701 Why Should My Signal Fit Within The Screen Of My Tektronix Oscilloscope?
Scaling your signal to fit within the screen will remove signal distortion caused by clipping. Clipping is caused by exceeding the limits of the instrument's input. Tektronix's digital oscilloscopes are designed such that each division is 25 digital …60306 Programing - How do I get a Screen Capture from DPO4000 scope using Python?
There are a few things that are needed for programming with an oscilloscope. First it's important to have a copy of your oscilloscopes Programmers manual. This can be found be searching for manuals on Tek.com and specifying Programmers manual in the …64791 Programing - How to get and plot a waveform from DPO/MSO/MDO4000 Series scope in Python
There are a few things that are needed for programming with an oscilloscope. First it's important to have a copy of your oscilloscopes Programmers manual. This can be found be searching for manuals on Tek.com and specifying Programmers manual in the …64796 How can I increase the measurement accuracy using automated measurements vs cursors?
While Cursors are quick and easy at approximating measurements, using the automated measurements can give you a much better and accurate measurement results. Here are some techniques to be successful in making accurate measurements. Always use …62606 How do I utilize the math channel feature on a DPO/MSO/MDO3000 or DPO/MSO/MDO4000 Series oscilloscope?
There are three main functionalities on the Math button on this scope. They range from Dual Waveform Math, FFT (Fast Fourier Transform), and Advance Math. These three functionalities have a range of abilities and are explained in this short YouTube …64656 How do I mount a network drive on my MDO3000 or MDO4000C oscilloscope?
This procedure also applies to the DPO/MSO/MDO4000/4000B series oscilloscopes. Note: This Mount a network drive will not work with a direct (peer-to-peer) connection. Must go through your local DNS server. To begin, press the “Menu” button in the …66201 How do I connect an SMA male output to Oscilloscopes with TekVPI BNC inputs?
Use a Tektronix part number 015-0572-XX SMA female to BNC male adapter. This adapter will plug onto the BNC on the front of the scope and connect to a SMA cable. For more questions please press the "Contact Us" button on the right of the screen.63516 How do I reduce noise on signals using an oscilloscope?
There are many methods to reduce many types of noise on a signal. Tektronix oscilloscopes can do this through bandwidth limiting the scope input, averaging your signal, changing the sampling method to hi-resolution mode, and more. This video …64706 I recently registered our Tektronix oscilloscope, updated the firmware and am currently trying to activate the free DVM & Frequency Counter. I don’t see any software downloads for activating the DVM. Am I doing something wrong, or looking in the wrong spot?
After you have registered your oscilloscope on Tek.com, you should have received an email with instructions. The email is sent to the address you used to login to tek.com. If you haven't received the email after registration: Check your spam …468046 How do I set up a USB bus decode?
First you must have the USB module or option key that enables USB decoding for your scope as well as proper probes. For help finding the right probe use our probe selector tool. When you go into the bus option you must select USB and then make sure …64726 How do I utilize the measurement features on a DPO/MSO/MDO3000 and DPO/MSO/MDO4000 Series oscilloscope?
The Measurements are the same as the DPO/MSO2000 Series scopes. By going into the measurement menu you can add and remove up to 4 measurements. You can gate the measurements which allows you to only measure the part of the captured waveform that you …64651 How do I set up a RS232 bus decode?
The procedure to set up a RS232 bus decode and trigger is simple once you understand the basics. First you need to have the correct module or scope option. Second make sure your signal is on screen and taking up as much of the screen as possible with …64761 How do I run a Signal Path Compensation (SPC) on an DPO/MSO/MDO4000 Series oscilloscope?
Signal Path Compensation (SPC) should be run anytime you are getting DC offsets in your signals, or your scope has moved locations and might have changed temperature, or if it's been more then a month since your last SPC. This is a standard procedure …64681 How do I set up a I2C Bus Decode?
The procedure to set up a I2C bus decode and trigger is simple once you understand the basics. First you have to have the correct module or scope option. Second make sure your signal is on screen and taking up as much of the DAC as possible with good …64756 How do I set up an Ethernet bus decode?
Make sure your setup is prepared to decode, that you have the needed probes, scope options, test boards, etc. Once you have the options it's important to know how to use the options and probe your signal. To setup Ethernet bus decoding, turn on your …64731 How do I save and load a reference waveform to a DPO/MSO3000 series oscilloscope?
This Video will explain how to setup, save and load a reference waveform. It can be done through a USB flash drive or by internal memory. This method for using reference waveforms can be applied to all MSO/DPO2000, MSO/DPO3000, MSO/DPO/MDO4000 …64641 How Do I Set Up a Parallel Bus Decode?
For doing Parallel Bus decode Tektronix recommends using a MSO or MDO + MSO option Series oscilloscopes. This feature comes standard in the Bus menu and can be used in a variety of ways. Start by turning it on, selecting the channel and setting your …64771 How can I change the TekVISA Instrument descriptor “device name” used to identify the oscilloscopes to which I routinely connect?
Open TekVISA V4.0.0+ OpenChoice Instrument Manager by selecting Start -> All Programs -> TekVISA -> OpenChoice Instrument Manager.Select (highlight) the Instrument descriptor listed in the Instruments list for the connected Oscilloscope.Click the …66181 How do I clear my memory using TekSecure on a MSO/DPO/MDO4000 Series oscilloscope?
This procedure for clearing the memory on oscilloscope can be applied to the DPO/MSO/MDO4000, DPO/MSO3000 and DPO/MSO2000 Series oscilloscope families. By clearing the memory you will lose all saved reference waveforms, saved setups and all other …64686 How do I Set Up a LIN serial Bus decode?
For doing Local Interconnect Network (LIN) bus decode Tektronix recommends using a DPO/MSO/MDO series oscilloscope. This feature can be purchased as a module or option key on any of these types of oscilloscopes. Start by turning it on the bus channel …64781 How do I Set up a Military Standard 1553 serial bus decode?
For doing Military Standard 1553 bus decode Tektronix recommends using a DPO/MSO/MDO 2000 or higher series oscilloscope. This feature can be purchased as a module or option key on any of these types of oscilloscopes. Start by turning it on the bus …64776 How do I configure the LAN settings on an MDO4000C series oscilloscope?
This procedure also applies to the DPO/MSO/MDO4000B series oscilloscopes. As it stands now, all 4000 series scopes require a live network connection be made on the scope in order to set and save LAN settings. If the scope does not have a network …66236 How do I erase and declassify an MSO/DPO2000, MSO/DPO/MDO3000, and MSO/DPO/MDO4000 Series oscilloscope?
This example will show you how to declassify the MDO4000/B/C Series oscilloscope. This procedure also applies to the MSO/DPO4000/B, MSO/DPO/MDO3000, and the MSO/DPO2000/B series of oscilloscope.The first step in the declassification process is …66231 How do I utilize the XY display feature on a DPO/MSO/MDO4000 Series oscilloscope?
The XY display format can be used to measure the phase relationship between two or more synchronous signals. This measurement technique involves inputting one signal into the vertical system as usual and then another signal into the horizontal system …64666 What is aliasing and how do I detect it and fix it on my oscilloscope?
Aliasing is basically a form of under sampling and what is displayed on the scopes is an indistinguishable waveform. The under sampled waveform is then contstructed to look like a slower frequency waveform or a flat line in the case of the sample …64691 What is the standard warranty on the MDO4000C?
The MDO4000C comes standard with a 3 year product warranty on the instrument and a 1 year warranty on the probes. Note: The MDO4000C is the first product to offer a new service option called the Total Protection Plan with options for 3 or 5 years …72151 What is the maximum bit rate a decoded SPI bus can trigger on?
Different oscilloscopes have different triggering circuitry therefor the limits of what speeds can be achieved vary by scope. Please use the following table to easily look up your scope and determine your max SPI bus trigger level. For more …62256 What feature does the DPO4BND included?
DPO4BND includes the features for the following modules …72101 What are the acquisition bands in the MDO4000, MDO4000B, and MDO4000C?
The acquisition bands are as follows: 1) 9kHz - 3.75 GHz (MDO4000B/C) or 50 kHz - 3.75 GHz (MDO4000)2) 2.75 GHz - 4.5 GHz3) 3.5 GHz - 6.0 GHzThese three bands overlap, allowing the MDO to have a 1 GHz capture bandwidth at all center frequencies and …69341 What probes are supported on the RF input of the MDO3000 and MDO4000 series?
The RF input on the MDO3000 and MDO4000 series has an N connector, so the RF input can support cables, antennas, and other adapters typically used with a spectrum analyzer. The RF input is 50 ohms and it is AC coupled. Below is a listing of some …64506 What's included in the MDO3000 and MDO4000C DDU option?
The Distribution Demo Unit (DDU) option on Tektronix oscilloscopes is an option provided to distributors for demoing scopes to customers with a set time limit before it expires. Questions arise about what's included in the MDO3000 and MDO4000C Series …72196 What are some of the benefits of the TekVPI probe interface?
The biggest benefits of the TekVPI™ probe interface are versatility and ease of use. Oscilloscopes with TekVPI interface support a wide range of probes including TekVPI probes, BNC and TekProbe-BNC Level 1 probes, and TekProbe-BNC Level 2 probes …56016 How do I set up a CAN bus decode?
Depending on what scope you have will depend on what options are availiable for decoding your CAN signal. For all the DPO/MSO2000/3000/4000/5000 and MDO3000/4000 Series scopes there are modules or license keys that can be purchased. Once you have one …64751 Do we get a Spectrum Analyzer equal to the analog bandwidth with a purchase of the MDO4000C?
No, all MDO4000C come without Spectrum Analyzer (SA) options. For flexibility you can now order the base unit and add either option MDO4SA3 (3GHz RF channel) or MDO4SA6 (6GHz RF channel). When MDO4SA3 or MDO4SA6 is NOT ordered, the oscilloscope comes …72131 Do the existing MSO/DPO/MDO4000/B Series application modules work with the MDO4000C?
Yes, almost all work from all legacy MSO/DPO/MDO4000/B series scopes. The only one that has some requirements is the MDO4TRIG which requires a spectrum analyzer option MDO4SA3 or MDO4SA6 be installed on your MDO4000C before RF triggering capabilities …72146 Does Tektronix have a 12-bit oscilloscope?
Yes! Tektronix offers many different models of real-time oscilloscopes that provide 12-bit or greater vertical resolution for a variety of applications. Because many high-vertical-resolution oscilloscopes on the market have technical trade-offs such …69266 The data sheet for my oscilloscope says that the vertical input sensitivity is 1 mV/div to 10 V/div in 1 MΩ mode. But I turn the Vertical Scale control fully clockwise and I can only get down to 10 mV/div. What am I doing wrong?
You probably aren't doing anything wrong. But you do have a 10X probe attached to that channel, right? The 1 mV/div specs relate to the oscilloscope inputs. If the signal’s source impedance is relatively low (<< 1 MOhm), the signal’s frequency is …58571 Is Analog BW upgradable on the MDO4000C and can it be upgraded in the field?
Yes, the MDO4000C analog bandwidth has upgradable bandwidth options. Once purchased it does require a new calibration at Tektronix Service Center.72121 : Can the optional AFG in the MDO3000, MDO4000C and 5 Series MSO be set to sweep?
AFG in MDO3000, MDO4000C, and 5 Series MSO do not have sweep function. But a limited sweep may be created using the arbitrary function. Example: Create a sweep from 100 KHz to 250 KHz. ArbExpress (free software on Tek.com) select Equation Editor …474056 My company purchased a Tektronix MDO4104C oscilloscope last year and we purchased three application modules. They are not showing up on our scope anymore and we would like some help getting them back.
Push Utility on the front panel. If needed, push Utility Page on the lower menu and turn multipurpose knob a to select Config. Push Manage Modules and Options on the lower menu, and then push License Type on the side menu until “Modules” is selected …468031 Will the P6516 Logic Probe work on my MSO4000B, MDO4000B and MDO4000C Series oscilloscopes?
The P6516 logic probe was only used with the original MSO4000 series. For the subsequent MSO4000B, MDO4000B and MDO4000C Series oscilloscopes, the P6516 was replaced by the P6616 logic probe. The P6616 logic probe will not work on the original …246206 Which probes are compatible with oscilloscopes with the TekVPI probe interface?
There are a couple different types of TekVPI interfaces, one with a notch and one without. The notch was implemented later and was put in place because the front end was designed differently and communicates uniquely with those types of probes …56226 I could not find any information regarding the increase in bits in resolution for HiRes mode. Is there any information available?
The increase in bits in resolution depends on the decimation ratio. The decimation ratio can be determined as follows:D = MFs / FsMFs is the maximum non-interleaved sampling frequency of the scope. For example: 5 GS/s for the DPO4104B or 2.5 GS/s …55421 I cannot see my signal on the Oscilloscope. What can I do?
You have many options to help diagnose this issue, below are a few suggestions to get started. If you find yourself needing more help, please connect with our Technical Support Center. You can get started by pressing the "Contact Us" button on the …63686 I downloaded and Installed OpenChoice Desktop, but it doesn't recognize my scope.
Refer to the Prerequisites.txt file available to download on the same page for OpenChoice desktop. Make sure you have all the prerequisites specified. Prerequisites 1. PC equipped with Microsoft Windows 7 32 Bit and 64 Bit OS, Windows 8.1 32 Bit …474266 When analog bandwidth is upgraded on a MDO4000C do we get new probes?
MDO4000C scopes with or less than 500MHz analog bandwidth come standard with TPP0500B 500MHz passive probes, one per channel. If upgrade to 1GHz analog bandwidth you will receive TPP1000 1GHz passive probes that come with the upgrade.72126 Is there a mictor adapter for the P6616 (logic probe for MSO5000B, MSO4000B, and MDO4000C + MDO4MSO) or P6516 (logic probe for the MSO4000 Series) or the P6316 (logic probe for MSO2000, MSO3000, MDO3000 + MDO3MSO Series)?
A mictor adapter is available from our partner Nexus Technologies. Use the mictor adapter NEX-HD2HEADER http://www.nexustechnology.com/products/laAccessories/hd2header/59716 Companies such as National Instruments and LeCroy sell USB-to-GPIB adapters. How do their adapters compare to the TEK-USB-488?
The products from National Instruments (GPIB-USB-B or GPIB-USB-HS) and LeCroy (WS-GPIB) are USB host to GPIB device adapter. These would be used for instruments that have a GPIB interface with controllers that have a USB port. The TEK-USB-488 was …56456 Can active probes with TekProbe interface (such as a P6205) be used on the DPO4000B or MSO4000B series scopes?
Yes. A TPA-BNC adaptor is required for people to connect legacy TekProbe interface probes to the new TekVPI interface. The adapter works on any TekVPI scopes inlcuding the MSO/DPO/MDO4000/B/C, MSO/DPO/MDO3000 MSO/DPO2000/B or MSO/DPO5000/B or …60416 Can my oscilloscope operate on 400Hz power?
Most scopes have a wide range of operating voltages and frequencies, a full list can be found in the user manual of your specific oscilloscope. If you're having trouble finding your answer or can't find the manual, please call our Technical Support …63266 Can the P6316, P6516, or P6616 logic probes be used interchangeably?
The simple answer is no they can't be used interchangeably. The front end of the logic channels are different so different logic probes are needed between the scopes. For MSO2000/B, MSO3000, and MDO3000 Series oscilloscopes, only the P6316 logic …59166 Can the MDO3000 capture the time domain and the frequency domain simultaneously?
The MDO3000 is most importantly an oscilloscope, but has a total of 6 different instruments individually built into it. Designed in such a way to minimize the clutter on your bench but give you the power and versatility you need. Unfortunately to be …69306 When should I use MagniVu on my oscilloscope?
MagniVu allows you to have higher resolution to accurately determine edge placement on your digital data. It helps you to make precise timing measurements on digital edges. On the MSO/MDO4000/B/C and MSO5000/B Series, you can see up to 32 times more …63886 When customer upgrades bandwidth on a MDO4000C, will the warranty be 3 years from the date of bandwidth upgrade?
No, the warranty does not get reset with the purchase of a bandwidth upgrade or spectrum analyzer upgrade. However, the instrument is returned from the Tektronix Service Center fully calibrated. If you have further questions please connect with our …72156 What are the primary differences between the DPO/MSO4000B, MDO4000, MDO4000B, and MDO4000C?
The 4000 Series Mixed Domain Oscilloscopes (MDO) continues to be the only true RF/Time domain syncronized instrument on the market. The major differences between revisions of the DPO/MSO/MDO4000 Series are described below. Please note the MDO4000C …72111 What cart does my scope use?
Below are the Instrument Carts that can be purchased from Tektronix. K4000 K420 K475 More information can …64561 What probe interface does my oscilloscope have?
Oscilloscope series Probe interface CSA7000/CSA7000B TekConnect DPO2000 TekVPI DPO3000 …64251 What is enhanced security option MDO4SEC on the MDO4000C?
Option MDO4SEC add’s enhanced instrument security to enable password protected control of turning on/off all instrument ports and instrument firmware update functionality. It is a one-time permanent upgrade.72141 What MDO4000C options can be upgraded in the field?
Only MSO, AFG & DVM/Frequency counter can be upgraded in the field. The DVM/Frequency counter is available on all models and is free when when the product is registered. Analog bandwidth upgrade options require the instrument to be calibrated at the …72136 Why does the Tkdpo2k3k4k_ReadWaveform() function in the Tkdpo2k3k4k IVI-C driver time out every time I call it when I am connected to the instrument via Ethernet? The function call works fine over USB, but over Ethernet it always times out.
The Tkdpo2k3k4k_ReadWaveform() function makes use of the Service Request Event in VISA so the scope can notify the driver when it has completed its acquisition and the waveform data is ready to be fetched as opposed to the driver polling the scope …72221