5 Series MSO Mixed Signal Oscilloscope

5 Series MSO Mixed Signal Oscilloscope

With a remarkably innovative pinch-swipe-zoom touchscreen user interface, the industry's largest high-definition display, and 4, 6, or 8 FlexChannel™ inputs that let you measure one analog or eight digital signals, the 5 Series MSO is ready for today’s toughest challenges, and tomorrow’s too. It sets a new standard for performance, analysis, and overall user experience.

Bandwidth

Up to 2 GHz

Record length

Up to 125 Mpoints

Analog channels

4 or 6 or 8

Digital Channels

Up to 64

More than just a new display and user interface. A new standard.

Get the big picture and take total control, with the 15.6 HD touchcreen display. Use the capacitive pinch-zoom-swipe touchscreen, front panel controls, or mouse to analyze and manage multiple signals without fighting through menus.

Don't run out of channels.

Available with 4, 6, or 8 FlexChannel inputs. Each can be used to look at 1 high-resolution analog waveform or look at 8 digital logic waveforms, just by changing the probe.

Let no detail go unseen, with up to 16 bits of vertical resolution.

Small-detail-on-I2C-Clock-Signal

12-bit analog to digital converters deliver up to 16 bits of vertical resolution using advanced digital signal processing. See and measure small signal details, even if they're riding on large signals.

Buy what you need now. Add on as your needs change.

Elemental-MSO58-007

Performance

  • Bandwidth up to 2 GHz
  • Record Length up to 125 Mpoints

Digital Inputs

  • TLP058 Logic Probes each provide 8 digital channels

Operating System

  • Add Windows OS to run PC software on the scope

Signal Generation

  • Add a built-in Arbitrary/Function Generator

Advanced Analysis

  • Serial Decode/Trigger support for key buses like I2C, SPI, USB 2, Ethernet, CAN, LIN, many others
  • Automated compliance testing for Automotive Ethernet
  • Advanced Jitter Analysis
  • Automated Power Measurement and Analysis

What's in the box?

8-channel MSO58 model shown
  • 1 passive probe per input channel:
    • TPP0500B (500 MHz) when you choose either the 350 or 500 MHz bandwidth option
    • TPP1000 (1 GHz) when you choose either the 1 or 2 GHz bandwidth option
  • 1-year warranty on the included probes
  • 3-year warranty on the instrument
  • Mouse, power cord and front cover with attached accessory pouch
  • Printed Installation Manual covers safety and basic operation
  • Comprehensive Integrated Online Help
  • Certificate of traceability

Models

Model Analog Bandwidth Sample Rate Record Length Analog Channels Digital Channels Function Generator Output List Price
MSO54 350 MHz - 2 GHz 6.25 GS/s 62.5 Mpoints - 125 Mpoints 4 Up to 32 (optional)

1 (optional)

US $13,000
Configure & Quote
MSO56 350 MHz - 2 GHz 6.25 GS/s 62.5 Mpoints - 125 Mpoints 6 Up to 48 (optional)

1 (optional)

US $16,200
Configure & Quote
MSO58 350 MHz - 2 GHz 6.25 GS/s 62.5 Mpoints - 125 Mpoints 8 Up to 64 (optional)

1 (optional)

US $21,800
Configure & Quote
ModelMSO54
List PriceUS $13,000
Analog BandwidthSample RateRecord Length
350 MHz - 2 GHz6.25 GS/s62.5 Mpoints - 125 Mpoints
Analog ChannelsDigital ChannelsFunction Generator Output
4Up to 32 (optional)

1 (optional)

ModelMSO56
List PriceUS $16,200
Analog BandwidthSample RateRecord Length
350 MHz - 2 GHz6.25 GS/s62.5 Mpoints - 125 Mpoints
Analog ChannelsDigital ChannelsFunction Generator Output
6Up to 48 (optional)

1 (optional)

ModelMSO58
List PriceUS $21,800
Analog BandwidthSample RateRecord Length
350 MHz - 2 GHz6.25 GS/s62.5 Mpoints - 125 Mpoints
Analog ChannelsDigital ChannelsFunction Generator Output
8Up to 64 (optional)

1 (optional)

Model Analog Bandwidth Sample Rate Record Length Analog Channels Digital Channels Function Generator Output List Price
MSO54 350 MHz - 2 GHz 6.25 GS/s 62.5 Mpoints - 125 Mpoints 4 Up to 32 (optional)

1 (optional)

US $13,000
Configure & Quote
MSO56 350 MHz - 2 GHz 6.25 GS/s 62.5 Mpoints - 125 Mpoints 6 Up to 48 (optional)

1 (optional)

US $16,200
Configure & Quote
MSO58 350 MHz - 2 GHz 6.25 GS/s 62.5 Mpoints - 125 Mpoints 8 Up to 64 (optional)

1 (optional)

US $21,800
Configure & Quote
ModelMSO54
List PriceUS $13,000
Analog BandwidthSample RateRecord Length
350 MHz - 2 GHz6.25 GS/s62.5 Mpoints - 125 Mpoints
Analog ChannelsDigital ChannelsFunction Generator Output
4Up to 32 (optional)

1 (optional)

ModelMSO56
List PriceUS $16,200
Analog BandwidthSample RateRecord Length
350 MHz - 2 GHz6.25 GS/s62.5 Mpoints - 125 Mpoints
Analog ChannelsDigital ChannelsFunction Generator Output
6Up to 48 (optional)

1 (optional)

ModelMSO58
List PriceUS $21,800
Analog BandwidthSample RateRecord Length
350 MHz - 2 GHz6.25 GS/s62.5 Mpoints - 125 Mpoints
Analog ChannelsDigital ChannelsFunction Generator Output
8Up to 64 (optional)

1 (optional)

  Tektronix
5 Series MSO
Tektronix
MSO/DPO5000B
Keysight
S-Series
LeCroy
HDO6000A/HDO8000A
Rohde & Schwarz
RTO2000
Yokogawa
DLM4000 Series
Detailed Comparison -- -- Fact Sheet Fact Sheet Fact Sheet Fact Sheet
Bandwidth 350 MHz to 2 GHz 350 MHz to 2 GHz 500 MHz to 8 GHz 350 MHz to 1 GHz 600 MHz to 6 GHz 350 MHz, 500 MHz
Upgradeable Bandwidth Yes No Yes No Yes No
Analog Channels 4, 6, or 8 4 2 or 4 4 or 8 2 or 4 8
Analog Sample Rate (All Channels) Up to 6.25 GS/s Up to 5 GS/s Up to 10 GS/s Up to 2.5 GS/s Up to 10 GS/s 2.5 GS/s
Standard Record Length (All Channels) 62.5 M 25 M 50 M 50 M 50 M 25 M
Integrated Arbitrary/Function Generator 50 MHz (opt.) -- -- -- 100 MHz (opt.) --
Digital Channels (MSO) Up to 64 (opt.) 16 (opt.) 16 (opt.) 16 (opt.) 16 (opt.) 8 (std) / 24 (opt)
ADC Resolution 12-bits 8-bits 10-bits 12-bits 8-bits 8-bits
Waveform Capture Rate >500,000 wfms/sec 250,000 wfms/sec <1,100 wfms/sec <700 wfms/sec 1,000,000 wfms/sec N/A
Operating System Closed Linux
Open Windows (opt.)
Open Windows Open Windows Open Windows Open Windows Closed
Standard Probes Up to 1 GHz Passive
< 3.9 pF Loading
Up to 1 GHz Passive
< 3.9 pF Loading
500 MHz Passive
9.5 pF loading
500 MHz Passive
10 pF loading
500 MHz Passive
10 pF loading
500 MHz
10.5 pF loading
Standard Warranty 3 years 1 year 3 years 3 years 3 years ?

Embedded Serial Bus Analysis

5series-mixed-signal-oscilloscope-serial-bus.jpg

Automatic serial bus decoding saves time and eliminates errors versus hand decoding. Serial bus triggering and search enable you to isolate events for system-level troubleshooting.

Highlights

  • I2C, SPI
  • USB 2.0
  • Ethernet
  • CAN, CAN FD, LIN, FlexRay
  • SENT
  • I2S/LJ/RJ/TDM
  • ARINC 429, MIL-STD-1553

Automotive Serial Bus Analysis

car-mso5-1

Car designers rely on serial buses for error-free communications between ECUs, sensors and actuators. They can also rely on the 5 Series MSO, equipped with CAN, CAN FD, LIN, FlexRay, and SENT decoding and triggering to be able to get a synchronized view of their systems. The automated Automotive Ethernet compliance suite lets you test to the standard, without becoming high speed bus expert.

Jitter Analysis

5series-mixed-signal-oscilloscope-jitter.jpg

Clocks are the heart of every embedded system and digital communication link. Jitter and other clock distortion can impact system operation, and getting to the root cause can be challenging without the right analysis tools.

Highlights

  • Standard phase noise, TIE, and frequency plots and histograms
  • Optional advanced analysis with jitter decomposition and clock recovery

Power Electronics

5-Series-MSO_Elemental_Shot_6_116

Make reliable, repeatable power quality, harmonics, switching loss, safe operating area measurements and more with the automated power measurement and analysis package. With up to 8 high-resolution channels and a wide range of available probes, the 5 Series MSO is also ideal for evaluating power supply sequencing, and digging into 3-phase power converters.

Highlights

  • Power quality and harmonics
  • Switching loss and safe operating area
  • In-circuit inductor and transformer analysis
  • Multi-output efficiency

Access Digital Channels

Upgrade Description Purchasing Details
TLP058 Logic Probe Each probe accesses 8 digital channels on any FlexChannel for any 5 Series MSO Request a quote on this probe

Add Instrument Functions

Upgrade Description Purchasing Details
SUP5-AFG Add arbitrary function generator Request trial license

Request a quote
SUP5-DVM Add digital voltmeter / trigger frequency counter Software upgrade license file provided upon registration.
Register now.
SUP5-RL-125M Extend record length to 125 Mpts / channel Request trial license

Request a quote
SUP5-WIN Add removable solid state drive with Windows 10 license installed. No trial available

Request a quote

Add Protocol Analysis

Upgrade Description Purchasing Details
SUP5-SRAERO Aerospace serial triggering and analysis (MIL-STD-1553, ARINC429) Request trial license

Request a quote
SUP5-SRAUDIO Audio serial triggering and analysis (I2S, LJ, RJ, TDM) Request trial license

Request a quote
SUP5-SRAUTO Automotive serial triggering and analysis (CAN, CAN FD, LIN, FlexRay) Request trial license

Request a quote
SUP5-SRAUTOSEN Automotive sensor serial triggering and analysis (SENT) Request trial license

Request a quote
SUP5-SRCOMP Computer serial  triggering and analysis (RS-232/422/485/UART) Request trial license

Request a quote
SUP5-SREMBD Embedded serial triggering and analysis (I2C, SPI) Request trial license

Request a quote
SUP5-SRENET Ethernet serial triggering and analysis (10Base-T, 100Base-TX) Request trial license

Request a quote
SUP5-SRUSB2 USB 2.0 serial bus triggering and analysis (LS, FS, HS) (≥ 1 GHz model recommended for HS) Request trial license

Request a quote

Add Serial Compliance Testing

Upgrade Description Purchasing Details
SUP5-CMAUTOEN Automotive Ethernet (100Base-T1 and 1000BASE-T1) automated compliance test solution Request trial license

Request a quote
SUP5-CMUSB2 USB 2.0 automated pre-compliance test solution Request trial license

Request a quote

Add Advanced Analysis

Upgrade Description Purchasing Details
SUP5-DJA Advanced jitter and eye analysis Request trial license

Request a quote
SUP5-PWR Power analysis Request trial license

Request a quote

Upgrade Bandwidth

Upgrade Description Purchasing Details
SUP5-BWxTy8 MSO58 bandwidth upgrade from x to y, where x and y are the hundreds of MHz
  • Up to 1 GHz upgrades can be performed in the field.
  • 2 GHz upgrade requires installation at a Tektronix Service Center via option IFC or IFCIN.
  • Bandwidth upgrades from 350 or 500 MHz, to 1 or 2 GHz also include one TPP1000 1 GHz passive probe per channel.
SUP5-BWxTy6 MSO56 bandwidth upgrade from x to y, where x and y are the hundreds of MHz
SUP5-BWxTy4 MSO54 bandwidth upgrade from x to y, where x and y are the hundreds of MHz
Low Voltage Single Ended Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TAP1500 Active Probe: 1.5 GHz, 10X, Single-ended, TekVPI Configure & Quote
TAP2500 Active Probe: 2.5 GHz, 10X, Single-ended, TekVPI Configure & Quote
Current Probe
Datasheet LinkProbeDescriptionConfigure and Quote
TCP0020 Probe, AC/DC Current; 20 Amp; 50 MHz BW; TekVPI Interface; Certificate of Traceable Calibration Standard Configure & Quote
TCP0030A

Probe, AC/DC Current; 30 Amp DC, DC TO 120 MHZ; with TekVPI Interface; Certificate of Traceable Calibration Standard

Configure & Quote
TCP0150 Current Probe: 20 MHz, 5 mA to 212 A, AC/DC, TekVPI Configure & Quote
High Voltage Differential Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TDP0500 Differential Probe: 500 MHz, 5X/50X, +/- 42V, TekVPI Configure & Quote
TDP1000 Differential Probe: 1 GHz, 5X/50X, +/- 42V, TekVPI Configure & Quote
THDP0100

Differential PROBE; 100 MHZ TekVPI DIFFERENTIAL HIGH VOLTAGE PROBE

Configure & Quote
THDP0200

Differential PROBE; 200 MHZ TekVPI DIFFERENTIAL HIGH VOLTAGE PROBE

Configure & Quote
TMDP0200

Differential PROBE; 200 MHZ TekVPI DIFFERENTIAL MEDIUM VOLTAGE PROBE;TMPD0200

Configure & Quote
Low Voltage Differential Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TDP1500 Differential Probe: 1.5 GHz, 1X/10X, +/-8.5V, TekVPI Configure & Quote
TDP3500

Differential Probe: 3.5 GHz, 5X, +/- 2V, TekVPI

Configure & Quote
Isolated Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TIVH02

Differential Probe; 200 MHZ, 50X/500X, TekVPI, 3 Meter Cable

Configure & Quote
TIVH02L Differential Probe; 200 MHZ, 50X/500X, TekVPI, 10 Meter Cable Configure & Quote
TIVH05

Differential Probe; 500 MHZ, 50X/500X, TekVPI, 3 Meter Cable

Configure & Quote
TIVH05L

Differential Probe; 500 MHZ, 50X/500X, TekVPI, 10 Meter Cable

Configure & Quote
TIVH08

Differential Probe; 800 MHZ, 50X/500X, TekVPI, 3 Meter Cable

Configure & Quote
TIVH08L

Differential Probe; 800 MHZ, 50X/500X, TekVPI, 10 Meter Cable

Configure & Quote
TIVM1 Differential Probe; 1 GHZ, 5X/50X, TekVPI, 3 Meter Cable Configure & Quote
TIVM1L Differential Probe; 1 GHZ, 5X/50X, TekVPI, 10 Meter Cable Configure & Quote
Logic Analyzer Probe
Datasheet LinkProbeDescriptionConfigure and Quote
TLP058

8 channel general purpose logic probe for 5 Series oscilloscopes. Includes accessory kit.

Configure & Quote
Passive Probe
Datasheet LinkProbeDescriptionConfigure and Quote
TPP0500B

Passive Probe: 500 MHz, 10X, TekVPI

Configure & Quote
TPP0502

Passive Probe: 500 MHz, 2X, TekVPI

Configure & Quote
TPP1000

Passive Probe: 1 GHz, 10X, TekVPI

Configure & Quote
High Voltage Single Ended Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TPP0850

High Voltage Probe: 800 MHz, 50X, 2.5 kV, Single-ended, TekVPI

Configure & Quote
Data SheetAccessoryDescription
HC5 Hard transit case for the 5 Series MSO
RM5 Rackmount kit for the 5 Series MSO
TitleTypeDate
RM5 Rackmount Kit Instructions
This document supports installing Tektronix 5 Series instruments in a standard 19-inch equipment rack.
Part number: 071352301
Field Install Instructions 26 Jan 2018
Using the 5 Series MSO FastFrame Segmented Memory
Learn how to use FastFrame segmented memory on the 5 Series MSO to capture more critical signal information by capturing important bursts and ignoring deadtime  
Literature number: 55W-61299-0
Technical Brief 22 Jan 2018
How To Save and Transfer a Screenshot from the 5 Series MSO
Screenshots (also known as hard copies) can be transferred from the Series 5 MSO oscilloscope via the remote programming interface using just a few simple commands.  For information on how to send commands to the instrument via the remote programming…
FAQ ID: 245436 18 Jan 2018
Difference between Position and Offset on an oscilloscope
To answer this first you need to understand the layout of how your waveform trace is displayed. On your oscilloscope you generally will see either 8 or 10 divisions vertically on the screen. Along the left side of the screen you will see a marker…
FAQ ID: 247211 16 Jan 2018
Debugging Serial Buses in Embedded System Designs
Learn the basics of the hardware protocols of the most common serial buses. Find out how to use the protocol trigger, decode and search capabilities of oscilloscopes to solve serial bus integration and debug challenges.
Literature number: 48W-19040-21
Application Note 24 Dec 2017
Debugging CAN, LIN and FlexRay Automotive Buses with an Oscilloscope
Explains the physical layer basics of CAN, LIN, and FlexRay serial buses to troubleshoot bus problems or system issues.  Learn how to use automated decoding, triggering, and search on an oscilloscope equipped with automotive bus analysis capability.
Literature number: 55W-61098-1
Application Note 24 Dec 2017
5 Series MSO Option SUP5-WIN SSD with Microsoft Windows 10 Upgrade Kit
This document describes how to install option SUP5-WIN, which provides a Microsoft Windows 10 environment on 5 Series MSO instruments (MSO54, MSO56, MSO58), and how to activate Windows once installed.
Part number: 071352400
Field Install Instructions 06 Dec 2017
5 Series MSO 12-bit Scope
Yes! Tektronix offers many different models of real-time oscilloscopes that provide 12-bit or greater vertical resolution for a variety of applications. Because many high-vertical-resolution oscilloscopes on the market have technical trade-offs such as…
FAQ ID: 69266 04 Dec 2017
5 Series MSO Software License Installation Process
After you place an order for an upgrade for your 5 Series MSO, you will receive an email (at the email address in your MyTek account). It will look about like this, but customized for you: Dear Customer ([email protected]) You have been authorized…
FAQ ID: 235451 01 Dec 2017
5 Series MSO Setup and Session Files
The 5 Series MSO setup files contain all instrument settings, user-configured analysis, and reference waveforms, so they provide an easy way to return the oscilloscope to a known state. For example, if you want to build a library of standardized tests,…
FAQ ID: 235446 01 Dec 2017
Downloads
Download

Download Manuals, Datasheets, Software and more:

Go to top