Download

Download Manuals, Datasheets, Software and more:

DOWNLOAD TYPE
MODEL or KEYWORD

Feedback

Arbitrary Waveform Generators

AWG2021

The products on this datasheet are no longer being sold by Tektronix.
View Tektronix Encore for reconditioned test equipment.
Check support and warranty status for these products.

Features & Benefits

  • 250 MS/s Clock Rate Provides up to 125 MHz Waveforms
  • 256 k Memory Depth
  • 12-Bit Vertical Resolution
  • Direct DSO Waveform Transfers
  • Region Shift Function Provides 4 ps Edge Placement
  • Optional 12-Bit 250 MHz (ECL) or 12/24-Bit 100 MHz (TTL) Digital Data Generator
  • Built-in 1.4 MB, 3.5 in. Floppy Disk
  • FFT Frequency Domain Editor (Opt. 09)
  • Real-time Waveform Sequencer to Easily Create Automatic Test Sequences and Extremely Long Patterns
  • Formula Entry of Waveforms
  • Channel Summing (with Opt. 02)
  • Fully Programmable from Front Panel, RS-232 and GPIB (IEEE-488.2)

Applications

  • Analog and Digital Modulation
  • Wireless Communication
  • All Forms of Fading Simulation
  • Navigation
  • I and Q Impairment
  • Audio
  • Computer Peripherals
  • Automotive
  • D/A and A/D Converter Testing
  • Filter Design
  • Semiconductor Logic (ASIC/DSP/FPGA)
  • CCD, LCD

The AWG2021 offers 250 MS/s and 256 k deep memory. As with the entire AWG2000 Series, the graphical user interface allows on-screen viewing of waveform editing, simplifying "what if" test scenarios by allowing the easy creation of composite signals.

The standard AWG2021 configuration provides one 5 V output or a second independent 5 V output (Opt. 02) each with 12-Bit vertical resolution. Frequency of channel 2 is also independently programmable. Option 03 adds a 12-Bit wide differential ECL digital port which can be used in conjunction with the marker outputs for data generation up to 14 Bits wide at up to 250 MHz. Or if you prefer, Option 04 provides TTL digital levels with up to two 12-Bit, 100 MS/s ports for a total of 28 Bits wide.

The built-in frequency domain (FFT) editor (Opt. 09) is a perfect addition for customers performing proprietary or standard modulation simulations, filter design or in physical layer testing. Real-time waveform sequencing extends the effective record length output to over a billion points!

The AWG2021 easily simulates signals where moderate point definition and long records are required for simulating very complex waveform conditions. Direct waveform transfer capability makes the AWG2021 the perfect complement to selected Tektronix oscilloscopes.

Characteristics

Standard Waveshapes

Sine, square, triangle, ramp, pulse, arbitrary, linked sequence and DC.

Arbitrary Waveforms

Execution Memory -

Waveform: 256 Kwords. Marker: 256 Kwords x 2 Bits.

Data Points of Waveform Size: 64 to 256 K in multiples of 8.

Real-time Sequencer Memory - 8 K individual waveforms.

Loop Counter: 1 to 65,535 repeats.

Burst Mode Counter: 1 to 64 K cycles.

Catalog Memory Clock

Frequency Range - 10 Hz to 250 MHz.

Resolution - 4 digit.

Accuracy - 50 ppm (+15 °C to +30 °C).

Skew between CH. 1 and CH. 2 (Opt. 02 only) - Within 4 ns.

Operating Modes

Continuous - Output continuous at programmed waveshape, frequency, amplitude and offset.

Triggered - Output quiescent until triggered by an external, GPIB or manual trigger; then generates a sequence only one time.

Gated - Same as triggered mode except period is executed only for the duration of the gated signal until the sequence started is completed.

Burst - Output quiescent until triggered by an external, GPIB or manual trigger; then generates "n" sequences or cycles.

Waveform Advance - Continuously generates the waveform in a predefined sequence; the next trigger advances to the next waveform in sequence.

Autostep - Generates the predefined waveform once in the Autostep File; the next trigger advances the waveform.

Main Output

Amplitude (Excluding ADD and Multiply Operation) -

Digital-to-Analog Resolution: 1/4096 (12-Bit).

Range: 0.05 V to 5 Vp-p into 50 Ω DC.

Accuracy: 0.05 V to 0.5 V, ±(0.5% of amplitude +5 mV); 0.501 V to 5 V, ±(1% of amplitude +25 mV).

Offset -

Range: -2.5 V to +2.5 V into 50 Ω, (-100 mA to +100 mA).

Resolution: 0.2 mA.

Accuracy: ±(1% of offset +0.2 mA).

Pulse Response -

15 °C to +30 °C: Flatness, within 3% after 20 ns from rise/fall edges; Aberrations, within 7% +10 mV.

+10 °C to +40 °C: Rise/Fall time, <4.2 ns; flatness, within 5% after 20 ns from rise/fall edges; aberrations, within 9% +10 mV.

Impedance - Typically 50 Ω.

Sinewave (Amplitude 1 V, 100 kHz Reference) -

Flatness: Within 4%.

THD: 1.0 V, ≤50 dBc, 0.5 V, ≤66 dBc.

Spurious: ≤66 dBc.

Channel Summing (Opt. 02 only)

AM (Multiply) -

Output: Within 5%.

Frequency Response: DC to 30 MHz.

External AM -

Sensitivity: 2 Vp-p (±5%) signal produces 100% modulation.

Frequency Response: CH 1, DC to 30 MHz; Ext. Signal, DC to 4 MHz.

Add -

Output: Within 5%.

Frequency Response: DC to 30 MHz.

Filters

3 dB Cutoff Frequency -

1 MHz: Within 20%.

5 MHz: Within 20%.

20 MHz: Within 20%.

50 MHz: Within 20%.

Delay -

1 MHz: Typically 390 ns.

5 MHz: Typically 78 ns.

20 MHz: Typically 18 ns.

50 MHz: Typically 11 ns.

Auxiliary Outputs

Markers 1 and 2 -

Amplitude:

Marker 1 >1.2 V into 50 Ω, >2.4 V into open circuit.

Marker 2 >1.2 V into 50 Ω, >2.4 V into open circuit.

Impedance: 50 Ω.

Marker to Signal Delay: Within 15 ns.

Sync -

Amplitude: >1.2 V into 50 Ω, >2.4 V into open circuit.

Impedance: 50 Ω.

Sync to Signal Delay: Within 15 ns.

Clock -

Amplitude: 1 V ±0.3 V into 50 Ω.

Impedance: 50 Ω.

Digital Data Out (Opt. 03, eliminates RS-232 Interface) -

Level: Differential ECL compatible.

Output Signals: Data (D0 to D11).

Skew Between Data: Within 1 ns.

Clock to Data Delay: Within 3 ns.

Connector: 68-Pin mini-D sub.

Auxiliary Inputs

Trigger -

Threshold Level: -5 V to +5 V.

Resolution: 0.1 V.

Accuracy: ±(5% x Level + 0.1 V).

Pulse Width: 15 ns minimum.

Input Swing: 0.2 V minimum.

Maximum Input Volts: 10 Vp-p when 1 MΩ selected; 5 VRMS when 50 Ω selected.

Impedance: 1 MΩ with 30 pF max.

Trigger to Output Signal Delay: External clock, 100 ns maximum +1 clock.

Trigger Holdoff - 5 μs maximum.

AM (Opt. 02 only) -

Range: 2 Vp-p (-1 V to +1 V) for 100% modulation.

Maximum Input: ±5 Vp-p, 10 kΩ impedance.

System Clock -

Threshold Level: 0.3 V ±0.1 V.

Input Swing: 0.8 V minimum.

Pulse Width: 2 ns minimum.

Maximum Input Voltage: ±2 Vp-p.

Impedance: 50 Ω.

Frequency Range: Up to 250 MHz phase coherent.

Programmable Interface

GPIB - IEEE 488.2-1987 compatible.

RS-232 - 9-Pin D connector.

Environmental

Temperature -

Operating: +10 °C to +40 °C.

Nonoperating: -20 °C to +60 °C.

Temperature Change -

Operating: +15 °C per hour (no condensation).

Nonoperating: +30 °C per hour (no condensation).

Humidity -

Operating: 20% to 80% (no condensation).

Nonoperating: 5% to 90% (no condensation).

Altitude -

Operating: To 4.5 km (15,000 ft.). Maximum operating temperature decreases 1 °C for each 300 m above 1.5 km.

Nonoperating: To 15 km (50,000 ft.).

Vibration - Operating: 0.33 mm p-p, 10 Hz to 55 Hz for 15 minutes.

Shock - Nonoperating: 30 G (1/2 sine) 11 ms duration.

Bench Handling - Operating: Drop from 10 cm (4 in.) tilt or 45°, whichever is less.

EMC -

Emissions: Within limits of FCC CFR 47, Part 15, Subpart B, Class A; VFG 243; EN55022, B; EN6055-2.

Immunity: Within limits of IEC 801-3, IEC 801-2, IEC 801-4.

Electrical Discharge - Operating max test voltage: 15 kV (150 pF through 150 Ω).

Safety - UL1244, CSA231, EN61010-1, IEC61010-1.

Power

Source Power -

Voltage Ranges: 90 to 127 V AC or 90 to 250 V AC.

Line Frequency: 90 to 127 V, 48 to 440 Hz; 90 to 250 V, 48 to 63 Hz.

Maximum Current - 4 A at 50 Hz, 90 V.

Maximum Power Dissipation - 300 W.

Fuse Rating - UL 198.6 (3AG): 6 AFAST, 250 V. IEC 127:5 A (T), 250 V.

Physical Characteristics

Dimensions

mm

in.

Weight

kg

lbs.

Height (with feet)

164

6.4

Width (with handle)

362

14.3

Length (with front cover)

491

19.25

Length (with handle extended)

576

22.2

Net

10.7

23.6

Ordering Information

AWG2021

250 MS/s Arbitrary Waveform Generator.

Includes: User/Programmer's Manual (070-9097-05/070-8657-05), GPIB programming examples disk, sample waveform library disk, Cal. Certificate, power cable.

Please specify power plug and manual version when ordering.

Recommended Accessories

Accessory Pouch - Order 016-1159-00.

Front Cover - Order 200-3232-01.

RS-232-C Cable - 9-Pin to 25-Pin. Order 174-1453-00.

Rackmount Kit - Order 040-1444-00.

12-Bit Digital Cable - Opt. 03 Order 012-1408-00 ECL Digital Cable. Opt. 04 Order 174-3129-00 TTL Digital Cable.

GPIB Cable - Order 012-0991-00.

Options

Opt. 02 - Independent, 256 K second channel.

Opt. 03*1 *3 - ECL digital cable. Order 012-1408-00.

Opt. 04*1 *2 *3 - TTL digital cable. Order 174-3192-00.

Opt. 09*1 - Add FFT editor. Allows editing waveforms in the frequency domain.

Opt. 1R - Rackmount. Floppy moved to front.

Opt. L0 - English manual.

*1 Options 03, 04 and 09 are mutually exclusive.

*2 12-Bit with single channel, 24-Bit with dual channel (Opt. 02).

*3 Eliminates RS-232 interface.

Power Plug Options

Opt. A0 - North America Power

Opt. A1 - Universal EURO Power

Opt. A2 - United Kingdom Power

Opt. A3 - Australia Power

Opt. A4 - 240 V, North America Power

Opt. A5 - Switzerland Power

Service

Opt. C3 - Calibration Service 3 Years

Opt. C5 - Calibration Service 5 Years

Opt. D1 - Calibration Data Report

Opt. D3 - Calibration Data Report 3 Years (with Option C3)

Opt. D5 - Calibration Data Report 5 Years (with Option C5)

Opt. R3 - Repair Service 3 Years

Opt. R5 - Repair Service 5 Years

Warranty