Keithley 2015 Series: THD and Audio Analysis Multimeter

Our audio analyzing multimeters combine audio band quality measurements and analysis with a broad purpose 6½-digit DMM—all in one half-rack instrument. They can measure total harmonic distortion (THD) over the complete 20Hz to 20kHz audio band and can compute THD+Noise and signal-to-noise plus distortion (SINAD). The 2015‑P and 2016-P directly identify peak values of the frequency spectrum. The 2016 and 2016-P have twice the sine wave generator output of the 2015 for applications that require test signals greater than 8Vrms. 

Price starting from
US $5,010 - US $5,430
2015
LIST PRICE
US $5,010
Maximum Resolution
Connectivity

6.5

GPIB / RS232

2015-P
LIST PRICE
US $5,430
Maximum Resolution
Connectivity

6.5

GPIB / RS232

Features

Benefits

Frequency domain analysis in conventional time domain instrumentsOffers broad range of measurements in one compact, half-rack instrument

Dual output audio band sine wave source

Generate stimulus signals with one output; the second one (inverse of the first output) simplifies testing differential input circuits for common mode or noise cancellation performance
Fast frequency sweepsCharacterize audio-band circuitry quickly in production test systems
Up to 64 harmonic magnitudes can be included in the distortion measurement Optimize accuracy, speed, and complexity for a specific test by programming the number of harmonics to be included in a computation
5 standard audio shaping filtersFilter out electromechanical noise on the production floor or simulate other types of system transmission characteristics
13 DMM functions (6½ digits)Minimize added equipment costs when configuring test setups
Data SheetAccessoryDescription
4288-1 SINGLE FIXED RACK MOUNTING KIT
4288-2 DUAL FIXED RACK MOUNTING KIT
5805 KELVIN PROBES, 0.9M (3FT)
5805-12 KELVIN PROBES, 3.6M (12 FT)
5808 LOW COST SINGLE PIN KELVIN PROBE SET
5809 LOW COST KELVIN CLIP
7007-1 SHIELDED GPIB CABLE,1M (3.2FT)
7007-2 SHIELDED GPIB CABLE,2M (6.5FT)
7007-3 SHIELDED GPIB CABLE,3M (10FT)
7009-5 5 FT. SHIELDED RS-232 CABLE
8605 MODULAR TEST LEADS
8606 MODULAR PROBE KIT
8608 HIGH PERFORMANCE CLIP-LEAD SET
8610 LOW THERMAL SHORTING PLUG
KPCI-488LPA LOW PROFILE IEEE-488 INTERFACE BOARD
KUSB-488B IEEE-488.2 USB-TO-GPIB INTERFACE ADAPTER
TitleType
#2297 Audio Analysis Testing Using a KPCI-3108 Board with LabWindows/CVI 5.0.1

Audio Analysis Testing Using a KPCI-3108 Board with LabWindows/CVI 5.0.1 Application Note # 2397 Manufacturers of cellular and cordless telephones employ a variety of methods to test the audio quality of their products during production. These tests may be as simple as measuring the Vrms of a sinewave input signal that is passed through the analog microphone and speaker circuits. In this case, a DMM usually offers sufficient measurement capability.

Application Note
How to Program an Instrument to Assert SRQ on the GPIB BusApplication Note
The Basics of Through-the-Air Audio Quality Test System CharacterizationWhitepaper
Model 2015 Total Harmonic Distortion Multimeter Specifications Rev. JSpecification
Model 2016 Total Harmonic Distortion Meter Specifications Rev. HSpecification
There’s much more to choosing a DMM than just its number of digits. With Tektronix wide range of DMMs, you can count on advanced features, speed, high basic accuracy, integration flexibility, and the…
0h 1m 27s
Downloads
Download

Download Manuals, Datasheets, Software and more: