Power Analyzer Accessories Datasheet

Read Online:

Fixed core Hall-effect transducers

Tektronix provides a variety of fixed core and split core current transducers matched to our power analyzers to fit your application and measurement needs. Fixed core transducers provide the highest accuracy available for both AC and DC current measurements, while the split core devices are ideally suited to making measurements in less accessible applications.

CT-xxxx-S Series

Thumbnail

The CT-xxxx-S series offer the highest accuracy and linearity when uncompromised measurements are required. These transducers are sourced from LEM, a high-quality component company.

Features

 

  • Very high accuracy (0.0054% - 0.0272%)
  • Excellent linearity (3 ppm - 20 ppm)
  • Extremely low temperature drift (0.5 ppm/k - 2.5 ppm/k)
  • Wide frequency bandwidth (DC to 800 kHz)
  • Closed loop (compensated) current transducer using an extremely accurate zero flux detector
  • Electrostatic shield between primary and secondary circuit
  • No insertion losses
  • High immunity to external electrostatic and magnetic fields interference
  • Low noise on output signal
  • Tektronix custom cable assembly included for easy connection to the PA3000 power analyzer
  • Compatible with standard PA3000 internal transducer supply (except CT-1000-S; order optional external power supply, Keithley models 2220 for two channels or 2231A for four channels)

 

Applications

 

  • High power converters and inverters
  • Motor drives
  • Solar inverters
  • UPS systems

 

CT-xxxx-M Series

Thumbnail

The CT-xxxx-M series are designed for general purpose measurement applications where accuracy requirements are less stringent. These transducers are sourced from LEM, a high-quality component company.

Features

 

  • Very good accuracy (0.4% - 0.5%)
  • Very good linearity (<0.1%)
  • Wide frequency bandwidth (DC to 150 kHz)
  • Closed loop (compensated) current transducer using the Hall Effect
  • Insulated plastic case recognized according to UL 94-V0.
  • Low temperature drift
  • Compatible with standard PA3000 internal transducer supply
  • Tektronix custom cable assembly included for easy connection to PA3000
  • No insertion losses
  • High immunity to external interference

 

Applications

 

  • High power converters and inverters
  • Motor drives
  • Solar inverters
  • UPS systems

 

Current clamps

Thumbnail

For quick connections in an environment where it is not possible to break the current path, a current clamp offers an easy way to measure AC current. The CL series current clamps are sourced from AEMC.

CL200

The CL200 is the latest in compact AC current probes. It is designed to provide quick connection to medium current circuits often found in industrial applications.

Features

 

  • 0.5 ARMS to 240 ARMS measurement range
  • 1000:1 transform ratio
  • 40 Hz to 10 kHz response
  • 1.0% to 3.0% accuracy, based on primary signal level
  • Small, compact size
  • Connects directly to Tektronix power analyzers
  • Large jaw opening accommodates conductors up to 250 MCM
  • Designed to EN61010, 600 V Cat. III safety standard

 

Applications

 

  • High power converters and inverters
  • Motor drives
  • Solar inverters
  • UPS systems

 

CL1200

The CL1200 is an AC current clamp designed for use in industrial and higher power environments. The ergonomic design allows it to easily clamp onto cables or small bus bars.

Features

 

  • 100 mARMS to 1200 ARMS measurement range
  • 1000:1 transform ratio
  • 30 Hz to 5 kHz response
  • 0.5% to 1.5% accuracy, based on primary signal level
  • Conforms to EN61010, 600 V Cat. III safety standard
  • Low phase shift for power measurements

 

Applications

 

  • High power converters and inverters
  • Motor drives
  • Solar inverters
  • UPS systems

 

Measurement accessories

 

These accessories help to simplify your circuit connections and make your measurement tasks easier.

Test leads
Thumbnail

.

PA-LEADSET Replacement lead set for Tektronix power analyzers. This insulated, stackable test lead set is rated for 1000 V, 32 A, CAT II, and is UL61010 compliant.

BB1000 Breakout Box

The BB1000 Breakout Box makes wiring connections between your device-under-test and Tektronix power analyzers easy and safe, by 'breaking out' the current flow for connection to the internal current shunt in the analyzer. It provides a line output socket to power your device under test (up to 10 ARMS) and 4 mm sockets for direct connection to the Tektronix power analyzer terminals. The BB1000 Breakout box is offered in different versions with these receptacle styles:

  • BB1000-UN: 120 V/240 V Universal receptacle
  • BB1000-NA: 120 V North America receptacle
  • BB1000-EU: 240 V Euro receptacle
  • BB1000-UK: 240 V United Kingdom receptacle
Thumbnail

BB1000-UN Breakout Box
Thumbnail


BB1000-NA Breakout Box
Thumbnail


BB1000-EU Breakout Box
Thumbnail


BB1000-UK Breakout Box
Ballast-CT

The Tektronix Ballast-CT simplifies the measurement of output power and tube current in high frequency electronic lighting ballasts. This device is specifically designed for lighting applications, and overcomes problems that are usually found when using conventional or Hall Effect current transformers. When used in conjunction with a Tektronix PA1000 or PA3000 power analyzer, the free-standing Ballast-CT accessory provides a convenient and accurate solution to taking power measurements in lighting ballast circuits.


Thumbnail


BALLAST-CT
  • Convenience: No need to feed cables through a CT core
  • High accuracy: Trifilar-wound toroidal design
  • No cable positioning/contact error
  • Wide bandwidth: High frequency design provides 5 kHz to 1 MHz bandwidth
  • Wide current range: 5 mA to 1 A is compatible with many modern ballasts

Specifications

All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise. The specifications are subject to change without notice.

CT-xxxx-S Series
ModelLEM part numberNominal primary current (rms)Nominal primary current (Ip, DC)Nominal secondary current (Is)Supply voltageSupply consumptionTransform ratioAccuracyBandwidth
CT-60-SIT 60-S42 A60 A100 mA±15 V80 mA + Is1:600 0.0272%DC to 800 kHz
CT-200-SIT 200-S141 A200 A200 mA±15 V80 mA + Is1:1000 0.0084%DC to 500 kHz
CT-1000-SIT 1000S/SP1707 A1000 A1 A±15 V80 mA + Is1:1000 0.0054%DC to 500 kHz

Notes:

The CT-1000-S transducer requires a separate power supply. Tektronix recommends the Keithley model 2220 for two channels or 2231A for four channels.

The secondary current (Is) = Imeasuredx the transform ratio.

CT-xxxx-M Series
ModelLEM part numberNominal primary current (rms)Nominal primary current (peak)Nominal secondary current (rms)Supply voltageSupply consumptionTransform ratioAccuracyBandwidth
CT-100-MLF 205-S/SP3100 A200 A100 mA±12 V to ±15 V17 mA + Is1:1000 ±0.5%DC to 100 kHz
CT-200-MLF 205-S/SP1200 A420 A100 mA±12 V to ±15 V17 mA + Is1:2000 ±0.5%DC to 100 kHz
CT-1000-MLF 1005-S1000 A1500 A200 mA±15 V to ±24 V28 mA + Is1:5000 ±0.4%DC to 150 kHz
CL Series
ModelAEMC part numberMeasurement rangeTransform ratioSupply voltageAccuracyBandwidth
CL200MN2130.5 A - 240 ARMS1000:1 Not needed1.0% - 3.0%40 Hz - 10 kHz
CL1200SR604100 mA - 1200 ARMS1000:1 Not needed0.5% - 3.0%30 Hz - 5 kHz
Ballast-CT
Operating current range
5 mA to 1 ARMS
Operating frequency
5 kHz to 1 MHz
Accuracy
Amplitude
Better than 1% (up to 500 kHz)
Phase
Better than 1 degree (up to 500 kHz)
Maximum voltage, tube/ballast to output or Earth
600 VRMS, CAT II
Isolation, tube/ballast to output
1 kVAC

Ordering Information

Models
CT-S Series
CT-60-S, CT-200-S, CT-1000-S
CT-M Series
CT-100-M, CT-200-M, CT-1000-M
CL Series
CL200, CL1200
Test Leads
PA-LEADSET
Breakout Box
BB1000-UN, BB1000-NA, BB1000-EU, BB1000-UK
Ballast-CT
BALLAST-CT
Accessories

All CT series current transducers (except for CT-1000-S) include cabling that allows easy and direct connection to the ±15 V supply on the PA3000 Power Analyzer, and directly to the 1 A shunt.

The CT-1000-S transducer requires a separate power supply. Tektronix recommends the Keithley model 2220 for two channels or 2231A for four channels, which can supply power for up to two CT-1000-S current transducers.

Warranty
All parts warranted for 1 year.
Last Modified: 2016-03-21 05:00:00
Downloads
Download

Download Manuals, Datasheets, Software and more:

Go to top