While we’re happy to “talk tech” with you all day long, we know you’re in a hurry. So we’ve made it easy for you to download manuals, datasheets and software for all our current products, and many discontinued products as well. Just tell us which product you’re using, and we’ll show you everything we have.
The product model you have chosen is currently available for purchase. The following support information is available.
-
Datasheet Literature Number: ReleaseDate AC/DC Current Measurement Systems
60W-16458-13 AC Current Probes
The P6021 and P6022 Current Probes provide versatile AC current measurements. Both probes provide accurate current measurements over a wide range of frequencies. The P6021 and P6022 allow current measurements without breaking the circuit by clipping …60W-06647-4 Current Probes
60W-60294-2 Current Probes
60W-15081-3 30 A AC/DC Current Probe
TCP0030A is a high-performance, easy-to-use AC/DC current probe designed for use and direct connection to oscilloscopes with the TekVPI™ probe interface. This AC/DC current measurement probe provides greater than 120 MHz of bandwidth with selectable …51W-19042-10 TCP0150 AC/DC Current Probe, Datasheet
51W-20815-5 AC Current Probes Datasheet
60W-12572-4 DC Coupled Current Probe
51W-10736-7 AC/DC Current Probes Datasheet
51W-28098-0
-
Manuals Manual Type Part Number: ReleaseDate A622 100 Amp AC/DC Current Probe Instructions
100 Amp AC/DC Current Probe User ManualPrimary User 070888306 TCP0030A
Current ProbePrimary User 071300601 Probes and Accessories
Declassification and SecurityDeclassification 071238400 TCPA300/400 & TCP300A/400 Series
Amplifiers & AC/DC Current ProbesPrimary User 077118302 TCPA300/400 and TCP303/305A/312A/404XL
Amplifiers and Current Probes Compliance and SafetyUser 071364301 TRCP0300, TRCP0600, and TRCP3000
Current ProbesPrimary User 077121300 TCPA300/400 & TCP300A/400 Series
Amplifiers & AC/DC Current ProbesPrimary User 077118301 AM503+ AM503A+ AM503B+ AM503S+ AM5030+ AM5030S Memory Information and Clearing
Click on this link to download the memory erasure information for AM503, AM503A, AM503B, AM503S, AM5030, AM5030S Current Probe AmplifiersDeclassification 067-1686-03
Power Measurement Deskew & Calibration FixturePrimary User 071187203 Tektronix Supplemental, 071329304
Product Information Sheet for People‚s Republic of ChinaUser 071329304 Tektronix Supplemental, 071329504
Product Information Sheet for the People‚s Republic of ChinaUser 071329504 A621
1000 Amp AC Current ProbePrimary User 070888205 A621 1000 Amp AC Current Probe
1000 Amp AC Current Probe InstructionsPrimary User 070888204 A622 100 Amp AC/DC Current Probe
100 Amp AC/DC Current Probe InstructionsPrimary User 070888305 TCPA300/400 & TCP300A/400 Series
Amplifiers & AC/DC Current Probes (Revision B) Service ManualService 077032301 CT-1 and CT-2
Current Transformer InstructionsPrimary User 070795702 TCP300 and TCP400 Series Instructions
AC/DC Current Probes InstructionsUser 071118501 TCPA300/400 and TCP300/400 Series
Amplifiers & AC/DC Current Probes Service ManualService 077032300 TCP202
15 Ampere AC/DC Current ProbePrimary User 070954203 P6022
Current Probe Instruction ManualPrimary User 070094805 TCPA300/400 & TCP300/400 Series
Revision A: Amplifiers & AC/DC Current ProbesPrimary User 077118300 067-1686-00
Power Measurement Deskew & Calibration Fixture InstructionsPrimary User 071187202 P6021
60 MHz Current Probe Instruction ManualService 070094707 TCP0150
20 MHz, 150 A AC/DC Current Probe Instruction ManualPrimary User 071225100 TCPA300/400 & TCP300/400 Series
Amplifiers & AC/DC Current Probes Instruction ManualPrimary User 071118303 TCP0030
Current Probe Instruction ManualPrimary User 071181200 067-1478-00 Power Measurements Deskew Fixture
Power Measurements Deskew Fixture InstructionsPrimary User 071117501 TCP202 Instruction Manual
15 Ampere AC/DC Current Probe Instruction ManualCombined User/Service 070954202 P6021 60 MHz Current Probe
60 MHz Current Probe Instruction ManualPrimary User 070094706 TCP202 Reference
15 Ampere AC/DC Current ProbeCombined User/Service 070954303 TCPA300/400, TCP300/400 Instruction Manual
AC/DC Current Measurement SystemsService 071118400 P6022 Instruction Manual
Current Probe Instruction ManualCombined User/Service 070094803 TCP202 Reference
15 Ampere AC/DC Current Probe ReferenceUser 070954302 CT-6 High Frequency AC Current Probe
High Frequency AC Current Probe Instruction ManualPrimary User 071045300
-
Technical Documents Document Type ReleaseDate Recommended Electronics Engineering Benches for Education
Whether you are teaching engineering fundamentals or more advanced topics like mixed-signal or RF analysis, Tektronix has a bench configuration for your education lab. Start with one of these recommended configurations for your engineering lab and …Technical Brief Magway Zero Emissions IMDA Case Study
Magway, an innovative start-up in London, is developing a new rail-based parcel delivery system with the help of advanced DQ axis analysis from Tektronix with the 5 Series MSO Mixed Signal Oscilloscope and current (TCP0030A) and differential voltage …Case Study Tektronix Probe Selection Guide
Probe / Oscilloscope Compatibility *1 Some probes require an external power supply (1103) when used with the TDS3000 series. *2 When using with MSO / DPO2000 series, a …Product Selector Guide Columbia University Case Study
Read this case study to learn how the Motor Drives and Power Electronics Lab (MPlab) at Columbia University’s Electrical Engineering used an MSO58 8-channel oscilloscope to analyze three-phase motor drives and multi-phase power electronics systems to …Case Study Tips and Tricks for Optimizing Low Power Measurements
Low-power measurements are becoming increasingly important in many line-powered and battery-powered applications, yet many engineers and technicians find it difficult to accurately make these measurements. Although most …Technical Brief In-Depth Review: DSP-equipped scopes provide 20-GHz of realtime bandwidth
Technical Brief The Probe
Measurement accuracy begins at the probe tip. To help you master the art of probing, we’ve consolidated the most common probing questions and pitfalls into this easy-to-print, 11x17 poster to post in your lab or workspace. Download your copy for …Poster Ensuring the Performance and Conformance of In-Vehicle Networks for New-Generation Automobiles
When comparing past, present and future automobiles, one trend is clear: cars have become data centers on wheels. Within each vehicle, the volume of data from safety systems, onboard sensors, navigation systems, and so on and the …Primer REVIEW: Cost-effective scopes time-correlate analog+ digital signals
Product Article Real-time 20-GHz-bandwidth DSO takes 50G samples/sec and captures four 200M-sample records at once
Product Article Tek oscilloscopes catch analog and digital signals
Product Article Tektronix MSOs Set Performance Benchmarks
Product Article Serial Analyzers for PCIe 2.0 Provide Power Management and Cross Bus Analysis
Product Article In-Depth Review: DSP-equipped scopes provide 20-GHz of realtime bandwidth
Product Article Tektronix Instruments Selected For HDMI Compliance Test
Product Article Making Accurate Current Measurements on Power Supplies with Oscilloscopes
This application note describes considerations and techniques for making accurate current measurements on power converters using an oscilloscope and a current probe. When used in conjunction with an oscilloscope’s voltage measurements …Application Note ABCs of Probes Primer
Precision Measurements Start at the Probe Tip Probes are vital to oscilloscope measurements. To understand how vital, disconnect the probes from an oscilloscope and try to make a measurement. It can’t be done. There has to be some …Whitepaper
-
FAQS FAQ ID Need a replacement power supply for, TRCP0300, TRCP0600, TRCP3000
Tektronix does not offer a replacement part number. The power supply an External Desktop AC to DC supply. 12V 1.6A with a barrel connector of 2.1mm ID and 5.5mm OD. Positive (+) inside; necitive (-) outside.772586 Do the TCP300 and TCP400 series current probes require amplifiers?
The TCP300 series require the TCPA300 current amplifier. The TCP404XL requires the TCPA400 current amplifier.58156 Which probes are compatible with oscilloscopes with the TekVPI probe interface?
There are a couple different types of TekVPI interfaces, one with a notch and one without. The notch was implemented later and was put in place because the front end was designed differently and communicates uniquely with those types of probes …56226 What are the maximum power draw ratings for the DPO3000/MSO3000 TEKVPI probes?
The MSO/DPO3000 Series scope can handle up to 20 Watts of attached probes. With an external adapter (Part #119-7465-xx) these scopes can reach up to 50 wattage requirement depending on probe requirements. Please see the download link below with a …61131 What current probes are compatible with the CT4 current transformer?
The CT4 can be used to extend the measurement capability of the P6021/A, A6302, A6312, TCP202/A,TCP0020 and TCP0030/A.The CT4 can also be used with the TCP 312/A and TCP305/A along with the TCPA300 amplifier. On some instruments, you may need to set …64056 What is the size of the TRCP current probe loops.
The size of the loops are given in this document.468376 Will The TCPA300 or TCPA400 current probe amplifier work with the older A6xxx series current probes?
No, the TCPA300 and TCPA400 will only work with their respective current probes, TCP312, TCP303, TCP305, and TCP404XL.61461 What are some of the benefits of the TekVPI probe interface?
The biggest benefits of the TekVPI™ probe interface are versatility and ease of use. Oscilloscopes with TekVPI interface support a wide range of probes including TekVPI probes, BNC and TekProbe-BNC Level 1 probes, and TekProbe-BNC Level 2 probes …56016 What is the delay or propogation delay for various Tektronix probes?
Probe delay in ns (Typical)P520517P521020P510014.9P50505.5TCP20217TCPA30519TCP30353TCP31217A631230A630355A6302XL6058741 What are the differences between the A and non A versions of the TCP0030, TCP312, TCP305 and P6021 current probes?
The TCP0030A, TCP312A, TCP305A, and P6021A probes are updates to their existing models. Updates include:Larger jaw diameter (5 mm vs. 3.8 mm) to accommodate larger wire sizes 3rd Party Certification for bare wire voltages up to 150 V CAT II - (Non-A …64841 What are the differences between the older TCP202 and current TCP202A?
Differences are: 1. The jaw size of TCP202 is 3.8 mm while the jaw opening for TCP202A is 5 mm. 2. The TCP202A is rated for 150 V Cat on bare wire.468406