DSA8300 Digital Sampling Oscilloscope

DSA8300 Digital Sampling Oscilloscope

With intrinsic jitter of less than 100 femtoseconds for extremely accurate device characterization, the DSA8300 Series provides comprehensive support for Optical Communications Standards, Time Domain Reflectometry and S-parameters. The DSA8300 Digital Sampling Oscilloscope is a complete high-speed PHY Layer testing platform for data communications from 155 Mb/sec to 400G PAM4.

Features

Benefits

Electrical module signal measurement accuracy:

  • Ultra-low system jitter (<100 fs, typical)
  • > 70GHz
<100 fs intrinsic jitter enables the characterization of high bit-rate (40 and 100 (4´25) Gb/s) devices with typically <5% of the signal’s unit interval being consumed by the test instrumentation. 70 GHz bandwidth allows full characterization of high bit-rate signals (5th harmonic to data rates of 28 Gb/sec and 3rd harmonic to data rates >45 Gb/sec).
Industry’s lowest system noise at all bandwidths:

  • 600 µV max (450 µV typ.) @ 60 GHz
  • 380 µV max (280 µV typ.) @ 30 GHz
Minimizes the amount of instrumentation noise when acquiring high bit-rate, low-amplitude signals to eliminate additional noise which can exhibit itself as additional jitter and eye closure.
Up to 6 channels simultaneous acquisition at <100 fs jitter in a single mainframe. High fidelity acquisition of multiple differential channels enables testing for cross channel impairments and improves the test throughput for systems with multiple high-speed serial channels.
Optical modules support optical compliance test of all standard rates from 155 Mb/s to 100 Gb/s (4x25) Ethernet. Provides cost-effective and versatile optical test system for single and multi-mode optical standards from 155 Mb/s (OC3/STM1) to 40 Gb/s (SONET/SDH and 40GBase Ethernet) and 100 Gb/s Ethernet (100GBase-SR4, -LR4 and ER4) at 850, 1310 and 1550nm.
Superior acquisition throughput with up to 300 kS/s maximum sample rate. Reduced manufacturing or device characterization test-time by 4X with superior system throughput.
Ability to place the samplers adjacent to the device under test (DUT). Remote sampling heads minimize signal degradation due to cabling and fixturing from DUT to instrumentation and simplifies test system de-embed.
Independent calibrated channel de-skew. Having integrated, calibrated channel deskew in dual channel modules, enhances signal fidelity for multi-channel measurements by eliminating skewing.

 

Models

Model Analog Bandwidth Sample Rate Record Length Analog Channels List Price
DSA8300 70 GHz Electrical, 80 GHz Optical Up to 300 kS/s 50 points - 16,000 points (1M points with IConnect®, 10M points for 80SJNB) Determined by the sampling modules used, up to 8 channels Configure & Quote
ModelDSA8300
Analog BandwidthSample RateRecord Length
70 GHz Electrical, 80 GHz OpticalUp to 300 kS/s50 points - 16,000 points (1M points with IConnect®, 10M points for 80SJNB)
Analog Channels
Determined by the sampling modules used, up to 8 channels
Model Analog Bandwidth Sample Rate Record Length Analog Channels List Price
DSA8300 70 GHz Electrical, 80 GHz Optical Up to 300 kS/s 50 points - 16,000 points (1M points with IConnect®, 10M points for 80SJNB) Determined by the sampling modules used, up to 8 channels Configure & Quote
ModelDSA8300
Analog BandwidthSample RateRecord Length
70 GHz Electrical, 80 GHz OpticalUp to 300 kS/s50 points - 16,000 points (1M points with IConnect®, 10M points for 80SJNB)
Analog Channels
Determined by the sampling modules used, up to 8 channels
Datasheet LinkProbeDescriptionConfigure and Quote
DVT30-1MM GigaProbe

30 GHz TDR probe available from GigaProbes.

Contact Us
P8018 HANDHELD TDR PROBE, PASSIVE; 20 GHZ, SINGLE-ENDED, 50 OHM, SMA CONNECTOR WITH 20 GHZ SMA CABLE; DESIGNED TO WORK WITH 80A02 EOS/ESD PROTECTION MODULE; STATEMENT OF COMPLIANCE INCLUDED WITH THIS PRODUCT Configure & Quote
P80318 Probe kit,18GHz 100 Ohm Differential Hand Probe Configure & Quote
Data SheetAccessoryDescription
80A02 EOS/ESD PROTECTION MODULE FOR ELECTRICAL STATIC ISOLATION OF TEKTRONIX ELECTRICAL SAMPLING MODULES;STATEMENT OF COMPLIANCE INCLUDED WITH THIS PRODUCT
80B28G 8000 Series - Electrical Sampling Scope Bundle to Support 25/28 Gb/s standards (includes 80E09B, 82A04B, CR286A and accessories)
80C07B OPTICAL SAMPLING MODULE; 2.488 GB/S OC48/STM16,2.500 GB/S 2GBE,2.500 GB/S INFINIBAND;2.5 GHZ OPTICAL BANDWIDTH
80C08D Single channel optical sampling module; 10G Optical Reference Receiver Filters; 12 GHz optical bandwidth; single-/multi-mode
80C10C Single Channel, 65/80 GHz Optical Sampling Module(must specify one of options F1, F2, or F3)
80C11B Single channel optical sampling module; 10G Optical Reference Receiver Filters; 28 GHz optical bandwidth; single-mode
80C12B 12 GHz, Broad WaveLength, Amplified Optical Sampling Module
80C14 14+ GHz, Broad WaveLength, Amplified Optical Sampling Module
80C15 8000 Series Optical Module: single channel, 32GHz optical bandwidth, single/multi-mode, 800nm to 1600nm
80C17 8000 Series Optical Module: single channel, 30GHz optical bandwidth, single/multi-mode, 800nm to 1600nm
80C18 8000 Series Optical Module: dual channel, 30GHz optical bandwidth, single/multi-mode, 800nm to 1600nm
80E03 SAMPLING MODULE; DUAL,20 GHZ ELECTRICAL SAMPLING MODULE - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD
80E04 SAMPLING MODULE; DUAL,20 GHZ W/TDR ELECTRICAL SAMPLING MODULE - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD
80E07B 8000 Series, Dual Channel, 30 GHz, Remote Electrical Sampling Module (includes D1)
80E08B 8000 Series, Dual Channel, 30 GHz, Remote Electrical Sampling Module w/ TDR (includes D1)
80E09B 8000 Series, Dual Channel, 60 GHz, Remote Electrical Sampling Module (includes D1)
80E10B 8000 Series, Dual Channel, 50 GHz, Remote Electrical Sampling Module w/ TDR (includes D1)
80E11 8000 Series, Dual Channel, 70 GHz, Ultra-low Jitter, Electrical Sampling Module (includes D1)
80E11X1 8000 Series, Single Channel, 70 GHz, Ultra-low Jitter, Electrical Sampling Module (includes D1)
82A04B 8000 Series, Phase Reference Module (includes D1)
82A04B 8000 Series, Phase Reference Module (includes D1)
Data SheetModuleDescriptionConfigure and Quote
80A02 EOS/ESD PROTECTION MODULE FOR ELECTRICAL STATIC ISOLATION OF TEKTRONIX ELECTRICAL SAMPLING MODULES;STATEMENT OF COMPLIANCE INCLUDED WITH THIS PRODUCT Configure & Quote
80B28G 8000 Series - Electrical Sampling Scope Bundle to Support 25/28 Gb/s standards (includes 80E09B, 82A04B, CR286A and accessories) Configure & Quote
80C07B OPTICAL SAMPLING MODULE; 2.488 GB/S OC48/STM16,2.500 GB/S 2GBE,2.500 GB/S INFINIBAND;2.5 GHZ OPTICAL BANDWIDTH Configure & Quote
80C08D Single channel optical sampling module; 10G Optical Reference Receiver Filters; 12 GHz optical bandwidth; single-/multi-mode Configure & Quote
80C10C Single Channel, 65/80 GHz Optical Sampling Module(must specify one of options F1, F2, or F3) Configure & Quote
80C11B Single channel optical sampling module; 10G Optical Reference Receiver Filters; 28 GHz optical bandwidth; single-mode Configure & Quote
80C12B 12 GHz, Broad WaveLength, Amplified Optical Sampling Module Configure & Quote
80C14 14+ GHz, Broad WaveLength, Amplified Optical Sampling Module Configure & Quote
80C15 8000 Series Optical Module: single channel, 32GHz optical bandwidth, single/multi-mode, 800nm to 1600nm Configure & Quote
80C17 8000 Series Optical Module: single channel, 30GHz optical bandwidth, single/multi-mode, 800nm to 1600nm Configure & Quote
80C18 8000 Series Optical Module: dual channel, 30GHz optical bandwidth, single/multi-mode, 800nm to 1600nm Configure & Quote
80E03 SAMPLING MODULE; DUAL,20 GHZ ELECTRICAL SAMPLING MODULE - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD Configure & Quote
80E04 SAMPLING MODULE; DUAL,20 GHZ W/TDR ELECTRICAL SAMPLING MODULE - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD Configure & Quote
80E07B 8000 Series, Dual Channel, 30 GHz, Remote Electrical Sampling Module (includes D1) Configure & Quote
80E08B 8000 Series, Dual Channel, 30 GHz, Remote Electrical Sampling Module w/ TDR (includes D1) Configure & Quote
80E09B 8000 Series, Dual Channel, 60 GHz, Remote Electrical Sampling Module (includes D1) Configure & Quote
80E10B 8000 Series, Dual Channel, 50 GHz, Remote Electrical Sampling Module w/ TDR (includes D1) Configure & Quote
80E11 8000 Series, Dual Channel, 70 GHz, Ultra-low Jitter, Electrical Sampling Module (includes D1) Configure & Quote
80E11X1 8000 Series, Single Channel, 70 GHz, Ultra-low Jitter, Electrical Sampling Module (includes D1) Configure & Quote
82A04B 8000 Series, Phase Reference Module (includes D1) Configure & Quote
82A04B 8000 Series, Phase Reference Module (includes D1) Configure & Quote
TitleTypeDate
Tektronix Introduces Optical Modules with Industry’s Highest Sensitivity, Lowest Noise
New Modules for DSA83000 Sampling Oscilloscope Increases Production Yields for 100G Designs; Tektronix adds comprehensive 400G PAM4 TDECQ Measurement
News Release 21 Mar 2017
Extinction Ratio (ER) Calibrated White Paper
This white paper explains some of the benefits of highly accurate ER measurements in both 10 GbE (Ethernet), with its relatively low ER requirement, and in SONET/SDH, and the methodology that supports consistent, accurate ER result.
Literature number: 85W-25115-1
Whitepaper 17 Jan 2017
TDR and S-parameter Measurements - How Much Performance Do You Need?
How TDR-based measurement tools can provide you a quicker way to making s-parameter measurements over the traditional VNA.
Literature number: 85W-19888-0
Application Note 17 Jan 2017
TDR Impedance Measurements: A Foundation for Signal Integrity
At today’s high operating frequencies, anything that affects your signal’s rise time, pulse width, timing, jitter or noise content can impact reliability at the system level.
Literature number: 55W-14601-2
Fact Sheet 17 Jan 2017
DSA8300 Series
Supports TekScope version 6.3.1.X and greater. This manual describes the installation and controls of the DSA8300 Digital Serial Analyzer, along with key operations and concepts.
Part number: 071289704
Primary User 06 Dec 2016
DSA8300 Digital Serial Analyzer
For DSA8300 TekScope release 6.2.1.X and greater. Instructions to install TekScope application and related software on the DSA8300 Digital Serial Analyzer sampling oscilloscope.
Part number: 071289804
Field Install Instructions 28 Oct 2016
DSA8300 and 80A00, 80C00, 80E00 Sampling Modules
Supports DSA8300 TekScope Application Software 6.3.1.x and above. This document describes the performance verification procedures for the DSA8300 Digital Serial Analyzer and supported electrical, optical, and accessory sampling modules.
Part number: 077068203
Performance Verification 22 Jun 2016
Can Microsoft Remote Desktop be used with Windows based oscilloscopes?
Yes, the Remote Desktop feature of the Professional Editions of Windows can be used on Tektronix DPO/MSO/CSA Series Oscilloscopes running Windows XP or later operating systems. In order to use the Remote Desktop feature of Windows, you will need to enable…
FAQ ID: 61606 24 Mar 2016
Remote Head Acquisition Improves High Speed Serial Measurement
Learn how to maximize the margin in your signal integrity measurements.
Literature number: 55W-29580-0
Application Note 19 Feb 2016
What cart does my scope use?
Below are the Instrument Carts that can be purchased from Tektronix.                                         K4000                                                                             K420                              K475 More information can be…
FAQ ID: 64561 11 Dec 2015
Downloads
Download

Download Manuals, Datasheets, Software and more: