質問:
How do I trigger on signals greater than 1Ghz?
回答:
The 11A81 has an External Trigger Input with a Trigger BW up to 2Ghz. You can either split your incoming using a power divider (which will cut the signal amplitude in half) or use another trigger source such as a synchronized clock output from a signal generator.