お問い合わせ
ダウンロード
マニュアル、データシート、ソフトウェアなどのダウンロード:
フィードバック
TLA700 Series Upgrade Guide
TLA7UP Mainframe Field Upgrade Kits
このデータ・シートの製品は、テクトロニクスでは販売終了となっています。
Tektronix Encoreプレミアム再生品を見るbr/>
上記製品のサポートと保証のステータスをチェックする
As Tektronix continues to improve the TLA700 logic analyzers, Tektronix will strive to ensure that there is a path for you to keep your mainframe current.
TLA715 or TLA721 Upgrades Available
If you own a TLA715 or TLA721 mainframe, you can upgrade the following capabilities using the TLA7UP Mainframe Field Upgrade Kit:
- Upgrade to add additional replaceable hard disks and a second internal fixed hard disk
- Upgrade to latest TLA Application Software, utilities, and Windows Operating System
- Upgrade to add external oscilloscope capability by adding the iView external oscilloscope interface
TLA7UP Mainframe Field Upgrade Kits
The TLA7UP kits are customer-installable field upgrade kits for the TLA700 Series which provide valuable enhancements to your TLA logic analyzer:
TLA700 Products Eligible for TLA7UP Upgrades*1
Configuration |
Operating System |
TLA Application Software |
---|---|---|
TLA715 Standard or with Option 1S
TLA721 Standard |
Windows 2000 Professional |
Version 4.1 and above |
TLA714 Standard or with Option 1S with TLA715 Controller Upgrade
TLA720 Standard with TLA721 Controller Upgrade |
Windows 2000 Professional |
Version 4.1 and above |
TLA714 Standard or with Option 1S
TLA720 Standard |
Windows 2000 Professional |
Version 4.0 and above |
Microsoft Windows 98 Second Edition |
Version 3.2 Version 3.1 Version 3.0 |
*1 1) TLA704 and TLA711 mainframes are no longer eligible for upgrades and TLA714 and TLA720 mainframes are no longer eligible for upgrades after Version 4.4, but might qualify for a “Mainframe Trade-In” program. Please contact your local Tektronix field representative for further details.
New Capability Desired |
Current Mainframe Configuration |
Current Operating System Version |
Current TLA Application Software Version |
Please Order |
---|---|---|---|---|
Add More DRAM & Larger HDD Add up to 512 MB DRAM and/or: 1) replace current hard disk with a larger, replaceable, bootable MAX hard disk drive (configured as master);
2) reconfigure replaceable hard disk drive for data storage only and add second, internal fixed, bootable hard disk drive (configured as master);
3) add an additional, replaceable MAX hard disk drive (configured as slave). |
TLA715 Std or Opt 1S
TLA721 Standard |
Windows 2000 Professional |
Version 4.4 |
TLA7UP Option 12 |
Version 4.3 Version 4.2 Version 4.1 Version 4.0 |
TLA7UP Option 12 TLA7UP Option 37 (w/ HD Image CD) [recommended]
-OR-
TLA7UP Option 36 (w/o HD Image CD) |
|||
TLA714 Std or Opt 1S with TLA715 Controller Upgrade
TLA720 Standard with TLA721 Controller Upgrade |
Windows 2000 Professional |
Version 4.4 |
N/A (TLA715 & TLA721 controller upgrade already includes MAX DRAM/HDD) |
|
Version 4.3 Version 4.2 Version 4.1 Version 4.0 |
N/A (TLA715 & TLA721 controller upgrade already includes MAX DRAM/HDD TLA7UP Option 35 (w/ HD Image CD) [recommended]
-OR-
TLA7UP Option 36 (w/o HD Image CD) |
New Capability Desired |
Current Mainframe Configuration |
Current Operating System Version |
Current TLA Application Software Version |
Please Order |
---|---|---|---|---|
Add New SW Features Add new functionality to existing TLA700 logic analyzer by upgrading to latest TLA Application Software.
TLA Applications Software requires Windows 2000 Professional Operating System. |
TLA715 Std or Opt 1S
TLA721 Standard |
Windows 2000 Professional |
Version 4.4 |
N/A |
Version 4.3 Version 4.2 Version 4.1 Version 4.0 |
TLA7UP Option 37 (w/ HD Image CD) [recommended]
-OR-
TLA7UP Option 36 (w/o HD Image CD) |
|||
TLA714 Std or Opt 1S with TLA715 Controller Upgrade
TLA720 Standard with TLA721 Controller Upgrade |
Windows 2000 Professional |
Version 4.4 |
N/A |
|
Version 4.3 Version 4.2 Version 4.1 Version 4.0 |
TLA7UP Option 37 (w/ HD Image CD) [recommended]
-OR-
TLA7UP Option 36 (w/o HD Image CD) |
New Capability Desired |
Current Mainframe Configuration |
Current Operating System Version |
Current TLA Application Software Version |
Please Order |
---|---|---|---|---|
Add New iView External Oscilloscope Capability Add new iView capability to view data from your TDS oscilloscope correlated directly on your TLA700 logic analyzer display
Requires latest TLA Application Software and Windows 2000 Professional Operating System.
TLA700 mainframe memory requirements: 256 MB minimum, 512 MB preferred.
(For a list of currently supported TDS oscilloscopes, please visit our website at www.tektronix.com). |
TLA715 Std or Opt 1S
TLA721 Standard |
Windows 2000 Professional |
Version 4.4 |
TLA7UP Option 15 |
Version 4.3 Version 4.2 Version 4.1 Version 4.0 |
TLA7UP Option 15 TLA7UP Option 37 (w/ HD Image CD) [recommended] -OR- TLA7UP Option 36 (w/o HD Image CD) |
|||
TLA714 Std or Opt 1S with TLA715 Controller Upgrade
TLA720 Standard with TLA721 Controller Upgrade |
Windows 2000 Professional |
Version 4.4 |
TLA7UP Option 15 |
|
Version 4.3 Version 4.2 Version 4.1 Version 4.0 |
TLA7UP Option 15 TLA7UP Option 37 (w/ HD Image CD) [recommended]
-OR-
TLA7UP Option 36 (w/o HD Image CD) |
New Capability Desired |
Current Mainframe Configuration |
Current Operating System Version |
Current TLA Application Software Version |
Please Order |
---|---|---|---|---|
Upgrade Logic Analyzer State Speed & Record Length Enhance your current TLA700 logic analyzer by increasing state speed or record length.
Run the PowerFlex Utility SW to inform you what PowerFlex upgrades are available.
Complete instructions on how to obtain an upgrade are provided. |
Any TLA700 series logic analyzer Mainframe |
— — |
Version 4.4 Version 4.3 |
Run PowerFlex Utility SW located on TLA700 and purchase appropriate TLA7Fxxx PowerFlex Kit. |
Version 4.2 or earlier |
TLA7UP Option PF
-OR-
Download the TLA PowerFlex Utility SW. |
New Capability Desired |
Current Mainframe Configuration |
Current Operating System Version |
Current TLA Application Software Version |
Please Order |
---|---|---|---|---|
Add CD-RW Drive Add CD-RW Drive to backup or transfer user & data files. |
TLA715 Std or Opt 1S
TLA721 Standard |
Windows 2000 Professional |
Version 4.4 |
TLA7UP Option 20 |
Version 4.3 Version 4.2 Version 4.1 Version 4.0 |
TLA7UP Option 20 TLA7UP Option 37 (w/ HD Image CD) [recommended]
-OR-
TLA7UP Option 36 (w/o HD Image CD) |
|||
TLA714 Std or Opt 1S with TLA715 Controller Upgrade
TLA720 Standard with TLA721 Controller Upgrade |
Windows 2000 Professional |
Version 4.4 |
TLA7UP Option 20 |
|
Version 4.3 Version 4.2 Version 4.1 Version 4.0 |
TLA7UP Option 20 TLA7UP Option 37 (w/ HD Image CD) [recommended]
-OR-
TLA7UP Option 36 (w/o HD Image CD) |
New Capability Desired |
Current Mainframe Configuration |
Current Operating System Version |
Current TLA Application Software Version |
Please Order |
---|---|---|---|---|
Add New Measurement Modules to Existing Mainframe Add new or existing TLA7Axx/NAx logic analyzer, TLA7Nx/Px/Qx logic analyzer, TLA7PG2 pattern generator and/or TLA7Dx/Ex digitizing oscilloscope module(s) to new or existing mainframe.
Requires latest TLA Application Software and Windows 2000 Professional Operating System. |
TLA715 Std or Opt 1S
TLA721 Standard |
Windows 2000 Professional |
Version 4.4 |
— — |
Version 4.3 Version 4.2 Version 4.1 Version 4.0 |
TLA7UP Option 37 (w/ HD Image CD) [recommended]
-OR-
TLA7UP Option 36 (w/o HD Image CD) |
|||
TLA714 Std or Opt 1S with TLA715 Controller Upgrade
TLA720 Standard with TLA721 Controller Upgrade |
Windows 2000 Professional |
Version 4.4 |
— — |
|
Version 4.3 Version 4.2 Version 4.1 Version 4.0 |
TLA7UP Option 37 (w/ HD Image CD) [recommended]
-OR-
TLA7UP Option 36 (w/o HD Image CD) |
New Capability Desired |
Current Mainframe Configuration |
Current Operating System Version |
Current TLA Application Software Version |
Please Order |
---|---|---|---|---|
Add New Pattern Generator Probes for PECL/LVPECL, LVDS, LVCMOS and Variable Data Strobe Support Add new or existing P6472 (PECL/LVPECL), P6473 (LVDS), P6474 (LVCMOS) and P6475 (Variable Data Strobe).
Requires Version 1.5 PatGen Application Software or greater, available as part of the latest TLA Application Software which requires Windows 2000 Professional. |
TLA715 Std or Opt 1S
TLA721 Standard |
Windows 2000 Professional |
Version 4.4 |
— — |
Version 4.3 Version 4.2 Version 4.1 Version 4.0 |
TLA7UP Option 37 (w/ HD Image CD) [recommended]
-OR-
TLA7UP Option 36 (w/o HD Image CD |
|||
TLA714 Std or Opt 1S with TLA715 Controller Upgrade
TLA720 Standard with TLA721 Controller Upgrade |
Windows 2000 Professional |
Version 4.4 |
— — |
|
Version 4.3 Version 4.2 Version 4.1 Version 4.0 |
TLA7UP Option 37 (w/ HD Image CD) [recommended]
-OR-
TLA7UP Option 36 (w/o HD Image CD |
New Capability Desired |
Current Mainframe Configuration |
Current Operating System Version |
Current TLA Application Software Version |
Please Order |
---|---|---|---|---|
Add New Expansion Mainframe to Existing Mainframe Add new or existing TLA7XM expansion mainframe to new or existing TLA700 mainframe.
Requires latest TLA Application Software and Windows 2000 Professional Operating System.
NOTE: TLA7UP Option 09 required for TLA720 mainframes with S/N B019999 or lower |
TLA715 Std or Opt 1S
TLA721 Standard |
Windows 2000 Professional |
Version 4.4 |
— — |
Version 4.3 Version 4.2 Version 4.1 Version 4.0 |
TLA7UP Option 37 (w/ HD Image CD) [recommended]
-OR-
TLA7UP Option 36 (w/o HD Image CD |
|||
TLA714 Std or Opt 1S with TLA715 Controller Upgrade
TLA720 Standard with TLA721 Controller Upgrade |
Windows 2000 Professional |
Version 4.4 |
— — |
|
Version 4.3 Version 4.2 Version 4.1 Version 4.0 |
TLA7UP Option 37 (w/ HD Image CD) [recommended]
-OR-
TLA7UP Option 36 (w/o HD Image CD |
New Capability Desired |
Current Mainframe Configuration |
Current Operating System Version |
Current TLA Application Software Version |
Please Order |
---|---|---|---|---|
Add LAN Card Add 10/100 Mb LAN interface to your TLA700 mainframe |
Any TLA714/715/720/721 |
— — |
— — |
119-6072-00 |
Add Cart |
Any TLA714/715/720/721 |
— — |
— — |
Choice of either K4000 or LACART |
Add Rackmount Kit |
Any TLA714/715 |
— — |
— — |
Recommend rack tray available from a number of third-party vendors. |
Any TLA720/721 |
— — |
— — |
020-2369-00 |
|
Add Wheeled Transport Case for TLA7xx |
Any TLA714/715 |
— — |
— — |
016-1522-00 |
Any TLA720/721/7XM |
— — |
— — |
016-1651-00 |
NOTES
- The latest TLA Application Software has been tested, can be installed, and will be supported by Tektronix only on the Tektronix-supplied version of Windows 2000 Professional.
- The TLA7UP is designed for “one TLA7UP per TLA714/715/720/721 mainframe”. If upgrading multiple TLA714/715/720/721s, you must order one TLA7UP with the appropriate options for each TLA714/715/720/721 mainframe.
- If you need to preserve your user files on your current mainframe’s hard disk, please order an additional hard disk drive using TLA7UP Option 10 (TLA714/720) or TLA7UP Option 12 (TLA715/721) and install it as a second, internal fixed hard disk in your mainframe. This procedure is documented in the TLA7UP Instruction Manual. For TLA7UP Option 16/17, TLA7UP Option 37 (new HDD Image CD-ROM) is required since there is a different controller with different drivers. Note that there are now two HDD Image CD-ROMs for the TLA700 mainframes: one for the TLA714/720 controller and a second for the new TLA715/721 controllers.
- Version 1.6 PatGen Application Software is available either as part of the latest TLA Application Software or on the Web (primarily for TLA704/711 and TLA714/720 users who have Windows 98 and Version 3.2 TLA Application Software).
- Note: the latest TLA Application Software on the Web does NOT have SnagIt, CheckIt nor the NI USB-to-GPIB SW due to licensing issues. Customers must order TLA7UP Option 36 or 37 to receive these SW components.
Current Version of TLA Application Software Downloadable From Tektronix Web Site
TLA application software is available for download and contains:
- Self-extracting image of the TLA application software
- Installation instructions
- Release notes
Note: All TLA application software has been tested, can be installed and will be supported by Tektronix only on Tektronix-supplied Windows 2000 Professional.
The downloadable version of TLA Application Software does not contain any non-Tektronix licensed software (including CheckIt Utilities, SnagIt, RecordNow Max, and National Instruments GPIB-USB Software). You can receive a copy of the full version by ordering TLA7UP with the appropriate option at no cost.
TLA Application Software Releases
Tektronix continues to innovate and enhance the TLA applications software for the TLA family of logic analyzers. The TLA5000, TLA600 and TLA700 logic analyzers share the same TLA applications software. Setups and data can be quickly and easily shared between the Series. Tektronix has demonstrated its commitment to continually improving the TLA family with several software upgrades since the original Version 1.0 release. The following table shows the compatibility of software used in the TLA by version numbers. Each software version is compatible with the other software versions in the same column. Each column indicates the software or firmware history of the TLA products as shipped from the factory.
Release |
4.4 |
4.3SP1 |
4.3 |
4.2SP1 |
4.2 |
3.2 |
---|---|---|---|---|---|---|
TLA Application SW |
4.4 |
4.3SP1 |
4.3 |
4.2SP1 |
4.2 |
3.2 |
TLA Application |
4.4.075 |
4.3.261 |
4.3.225 |
4.2.112 |
4.2.098 |
3.2.038 |
TLA7NAx FW |
4.4.005 |
N/A |
N/A |
N/A |
N/A |
N/A |
TLA7Axx FW |
4.4.005 |
4.3.037 |
4.3.034 |
4.2.084 |
4.2.081 |
NA |
TLA7N/P/Qx FW |
4.3.14 |
4.3.14 |
4.3.14 |
4.1.4 |
4.1.4 |
3.2.0 |
TLA7L/Mx FW |
3.2.1 |
3.2.1 |
3.2.1 |
3.2.1 |
3.2.1 |
3.2.1 |
TLA7D/Ex |
3.1.1 |
3.1.1 |
3.1.1 |
3.1.1 |
3.1.1 |
3.1.1 |
TLA6xx FW |
4.3.15 |
4.3.15 |
4.3.15 |
4.2.0 |
4.2.0 |
3.2.16 |
TLA520x FW |
4.4.001 |
4.3.032 |
4.3.028 |
NA |
NA |
NA |
MF Diagnostics |
4.4.075 |
4.3.261 |
4.3.225 |
4.2.098 |
4.2.098 |
3.2.038 |
Firmware Loader |
4.4.075 |
4.3.261 |
4.3.225 |
4.2.098 |
4.2.098 |
3.2.038 |
TLAScript |
4.4.075 |
4.3.261 |
4.3.225 |
4.2.112 |
4.2.098 |
3.2.038 |
TLASym |
4.4.075 |
4.3.261 |
4.3.225 |
4.2.112 |
4.2.098 |
3.2.038 |
AutoDeskew |
4.4.76.0 |
4.3.140.0 |
1.0.48.0 |
N/A |
N/A |
N/A |
ChannelImportExp |
4.3.2.0 |
4.3.2.0 |
1.0.4.0 |
N/A |
N/A |
N/A |
Graph Window |
4.4.76.0 |
4.3.141.0 |
1.0.50.0 |
N/A |
N/A |
N/A |
iVerify |
4.4.76.0 |
4.3.140.0 |
1.0.48.0 |
N/A |
N/A |
N/A |
Protocol Designer |
4.4.76.0 |
4.3.129.3 |
1.0.34.0 |
N/A |
N/A |
N/A |
Protocol Window |
4.4.76.0 |
4.3.143.0 |
1.0.50.0 |
N/A |
N/A |
N/A |
TLAVu |
4.4.075 |
4.3.261 |
4.3.225 |
4.2.112 |
4.2.098 |
3.2 |
TPI Client SW |
4.4.075 |
4.3.261 |
4.3.225 |
4.2.098 |
4.2.098 |
3.2 |
PatGen App SW |
1.6.011 |
1.5.003 |
1.5.003 |
1.4.002 |
1.3.032 |
1.0.000 |
PatGen FW |
2.01 |
2.01 |
2.01 |
2.01 |
2.01 |
2.01 |
PatGenVu |
1.6.011 |
1.5.003 |
1.5.003 |
1.4.002 |
1.3.032 |
1.01 |
PPI Client SW |
1.6.011 |
1.5.003 |
1.5.003 |
1.4 |
1.3.032 |
1.0 |
Windows 2000 |
5.00.2195 SP4 |
5.00.2195 SP4 |
5.00.2195 SP4 |
5.00.2195 SP4 |
5.00.2195 SP4 |
NA |
Windows 98 |
NA |
NA |
NA |
NA |
NA |
4.10.2222 |
MS .NET Framework |
1.1.4322 |
1.0.3705 |
1.0.3705 |
NA |
NA |
NA |
QA+Win32 |
NA |
NA |
NA |
NA |
NA |
2.0 |
SnagIt |
7.0.0 |
6.1.1 |
6.1.1 |
5.2 |
5.2 |
NA |
CheckIt Utilities |
7.0 |
7.0 |
7.0 |
6.5.5 |
6.5.5 |
NA |
NI-488.2 |
2.1 |
2.1 |
2.0 |
2.0 |
1.01 |
NA |
NI-MAX |
2.2.0 |
2.2.0 |
2.2.0 |
2.2.0 |
2.0.3.17 |
NA |
RecordNow MAX |
4.50 |
4.50 |
4.50 |
NA |
NA |
NA |
Click’N Burn Pro |
NA |
NA |
NA |
2.01 |
2.01 |
NA |
Adobe Reader |
6.0 |
6.0 |
6.0 |
5.0 |
5.0 |
NA |
TLA715/721 BIOS |
1.00.02 |
1.00.02 |
1.00.02 |
1.00.02 |
1.00.02 |
NA |
TLA714/720 BIOS |
2.03.11 |
2.03.11 |
2.03.11 |
2.03.11 |
2.03.11 |
2.03.11 |
TLA704/711 BIOS |
NA |
NA |
NA |
NA |
NA |
1.00.14 |
TLA600 BIOS |
P9-0009 |
P9-0009 |
P9-0009 |
P9-0009 |
P9-0009 |
0005.P05 |
TLA5200 BIOS |
0040.P16 |
0040.P16 |
0040.P16 |
NA |
NA |
NA |
Note: All TLA application software has been tested, can be installed, and will be supported by Tektronix only on Tektronix-supplied Windows 2000 Professional.
We are consistently adding to the list of supported oscilloscopes that combine with the TLA Series logic analyzers to provide iView (Integrated View) capability. The following table gives a history of oscilloscopes and TLA Application Software versions along with interim iView updates. This includes which version of TLA software supports which oscilloscopes.
|
TLA SW V4.4 Release |
TLA SW V4.3 SP1 |
TLA SW V4.3 Release |
iView V4.2.1 Upgrade |
TLA SW V4.2 SP1 |
TLA SW V4.2 Release |
iView V4.1.4 Upgrade |
iView V4.1.3 Upgrade |
TLA SW V4.1 SP2 |
iView V4.1.1 Upgrade |
TLA SW V4.1 Release |
---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
TLA App Version |
4.4 |
4.3 SP1 |
4.3 |
4.2 SP1 |
4.2 SP1 |
4.2 |
4.1 SP2 |
4.1 SP2 |
4.1 SP2 |
4.1 |
4.1 |
iView Version |
4.3.5 |
4.3.2 |
4.3.0 |
4.2.1 |
4.2.0 |
4.2.0 |
4.1.4 |
4.1.3 |
4.1.2 |
4.1.1 |
4.1.0 |
Date (approx) |
21-Jun-04 |
22-Dec-03 |
8-Aug-03 |
3-Apr-03 |
9-Aug-02 |
6-Apr-02 |
11-Jan-02 |
13-Nov-01 |
20-Sep-01 |
1-Aug-01 |
4-Jun-01 |
# of scopes |
55 |
53 |
42 |
40 |
32 |
32 |
32 |
27 |
18 |
17 |
12 |
|
|||||||||||
TDS724D |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
|
|
TDS754C |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
|
|
TDS754D |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
|
|
TDS784C |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
|
|
TDS784D |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
|
|
TDS794D |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
|||||||||||
TDS654C |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
TDS684C |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
TDS694C |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
|||||||||||
TDS1002 |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
|
|
|
TDS1012 |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
|
|
|
TDS2002 |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
|
|
|
TDS2012 |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
|
|
|
TDS2014 |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
|
|
|
TDS2022 |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
|
|
|
TDS2024 |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
|
|
|
|
|||||||||||
TDS3012 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
TDS3014 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
TDS3032 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
TDS3034 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
TDS3052 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
TDS3054 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
|||||||||||
TDS3012B |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
TDS3014B |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
TDS3032B |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
TDS3034B |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
TDS3052B |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
TDS3054B |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
|
|||||||||||
TDS5032 |
Yes |
Yes |
Yes |
|
|
|
|
|
|
|
|
TDS5034 |
Yes+iV |
Yes+iV |
Yes+iV |
|
|
|
|
|
|
|
|
TDS5052 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
|
|
TDS5054 |
Yes+iV |
Yes+iV |
Yes+iV |
Yes |
Yes |
Yes |
Yes |
Yes |
|
|
|
TDS5104 |
Yes+iV |
Yes+iV |
Yes+iV |
Yes |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
|||||||||||
TDS5032B |
Yes |
Yes |
|
|
|
|
|
|
|
|
|
TDS5034B |
Yes+iV |
Yes+iV |
|
|
|
|
|
|
|
|
|
TDS5052B |
Yes |
Yes |
|
|
|
|
|
|
|
|
|
TDS5054B |
Yes+iV |
Yes+iV |
|
|
|
|
|
|
|
|
|
TDS5054BE |
Yes+iV |
Yes+iV |
|
|
|
|
|
|
|
|
|
TDS5104B |
Yes+iV |
Yes+iV |
|
|
|
|
|
|
|
|
|
|
|||||||||||
TDS6404 |
Yes+iV |
Yes+iV |
Yes+iV |
Yes |
|
|
|
|
|
|
|
TDS6604 |
Yes+iV |
Yes+iV |
Yes+iV |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
|
|||||||||||
TDS6604B |
Yes+iV |
|
|
|
|
|
|
|
|
|
|
TDS6804B |
Yes+iV |
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
TDS7054 |
Yes+iV |
Yes+iV |
Yes+iV |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
TDS7104 |
Yes+iV |
Yes+iV |
Yes+iV |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
TDS7154 |
Yes+iV |
Yes+iV |
Yes+iV |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
TDS7254 |
Yes+iV |
Yes+iV |
Yes+iV |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Yes |
TDS7404 |
Yes+iV |
Yes+iV |
Yes+iV |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
|||||||||||
TDS7154B |
Yes+iV |
Yes+iV |
|
|
|
|
|
|
|
|
|
TDS7254B |
Yes+iV |
Yes+iV |
|
|
|
|
|
|
|
|
|
TDS7404B |
Yes+iV |
Yes+iV |
|
|
|
|
|
|
|
|
|
TDS7704B |
Yes+iV |
Yes+iV |
|
|
|
|
|
|
|
|
|
|
|||||||||||
CSA7154 |
Yes+iV |
Yes+iV |
Yes+iV |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
CSA7404 |
Yes+iV |
Yes+iV |
Yes+iV |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
|
|||||||||||
CSA7404B |
Yes+iV |
Yes+iV |
|
|
|
|
|
|
|
|
|
Notes:
- "Yes" means supported by iView.
- "Yes+iV" means supported by iView and iVerify.
Besides the latest features in Version 4.4 of the TLA application software, the following section shows the history of features added to the TLA application software.
Key NEW Features in TLA Application Software Releases for TLA700
Version 4.4 -
- TLA7NAx Logic Analyzer Modules for the TLA700 Series - including 8 GHz MagniVu timing, 2 GHz deep timing, 235 to 450 MHz state clock rates, 512 Kb to 32 Mb record length.
Version 4.3 -
- TLA5000 Series Logic Analyzers with 500 ps (2 GHz) deep memory timing with up to 32 Mb memory depth, with 125 ps MagniVu acquisition, simultaneous with 235 MHz state acquisition.
- TLACAL1 Calibration Fixture
- iLink™ Toolset
- IConnect™ - simultaneous analog and digital acquisition through a single logic analyzer probe
- iView™ - displays automatically time-correlated analog and digital data on a single logic analyzer display
- iVerify™ - enables multi-channel analysis and validation using high-resolution oscilloscope-generated eye diagrams
- Filter/Color
- Enhanced Search
- Graph Window
- AutoDeskew
- TPI.NET
- Protocol Display Window and Protocol Designer
- Multi-language Windows 2000 Professional
- Import/Export Channel and Group Definitions
- EasySetup Wizard
- Zoom Immediate
- DSO Channels have TDS Colors
- Microsoft Windows Colors
- LA Setup Toolbar
- Tools Toolbar and Menu Item
- Highlight Channel Names
- Rename Channel/Group from Data Window
- User-defined Default Waveform Height
- Support for LA Status Channels
- Per Channel Clock and Setup/Hold Violation Definition
- Merge Modules with Different State Speeds
Version 4.2 -
- TLA7Axx Logic Analyzer Modules for the TLA700 Series - including 8 GHz MagniVu timing, 2 GHz deep timing, 120 to 800 MHz state clock rates, 1.25 Gb/s data rates, 128 Kb to 64 Mb memory depth, 2 GHz analog multiplexer
- Low-capacitance, full differential, connectorless, 2 GHz active probing system with high-density and general-purpose probes
- 5-way module merging
- TLACAL2 calibration fixture
- CD-RW Drive for TLA6xx instruments and TLA700 mainframes
- 10/100 Mb LAN standard on all TLA700 mainframes
- iView (Integrated View) of your TDS data on your TLA display - support for TDS3000/3000B, TDS5000, TDS6000, TDS7000, CSA7000, TDS600C, TDS700C/D oscilloscopes EasyTrigger enhancements
Version 4.1 -
- Support for new TLA715 dual monitor portable mainframe
- Support for new TLA721 dual monitor benchtop mainframe
- Support for TLA714 controller upgrade
- Support for TLA720 controller upgrade
- Flat panel monitor options
- Wheel mouse support
- TLA-TDS interface for iView support of automatic data correlation from an external oscilloscope
- TDS3000, TDS7000, TDS684C/694C support
- iView setup wizard
- EasyTrigger
- Oscilloscope measurements
- Individual oscilloscope channel manual skew adjustment
- Overlay of waveforms
- Setup and Hold violation storage and display
- Setup and Hold window graphic control (advanced clocking)
- System trigger dialog
- Context-sensitive most-recently-used list
- Fast access to windows using hot keys
- Demux source and destination channel colors
- Trigger group values in more that one radix
- Magnitude waveform dot mode
- New Version 1.3 TLA7PG2 PatGen Application SW
- SnagIt software included (graphic capture software)
- CheckIt software included (diagnostic software)
Version 4.0 -
- TLA7Q2/Q4 64 M Logic Analyzer Modules
- Windows 2000 Professional with Service Pack 1, IME 5.01 and NTFS file system
- 500 MHz Timing on Half Channels at Twice Memory Depth
- Improved Logic Analyzer Demux Support
- Support for Up to Ten TLA7XMs
- Elf/Dwarf 2 object file format supported
- Support for >2 GB TLA System save/restore file operations (32-bit to 64-bit)
- New Version 1.1 TLA7PG2 PatGen Application SW
- Performance Verification and Adjustment Software Bundled in with TLA App SW
Version 3.2 -
- TLA600 Series Logic Analyzers
- TLA7PG2 Pattern Generator
- TLAVu and PatGenVu
- Waveform Windows Enhancements
- Windows 98-Second Edition
- Load System Enhancements
- Download TLA Software from Tektronix Website
Version 3.1 -
- Support for NEW TLA7XM Expansion Mainframe
- Sample Suppression
- Click & Drag Zoom
- Variable Time/Div
- Busform Expansion
- Click & Drag Waveform and Column Resizing
- Status Monitor Enhancements
- User-defined Tools directly accessible from TLA toolbar
- TLAScript
- TPI (TLA Programmatic Interface) Enhancements
- Microsoft Excel X-Y Plot Add-in
- Save System Enhancements including size, position and state of every window
- Magnitude Waveform and Color Symbols
- More tooltips
- OMF166 Object File Support
Version 3.0 -
- Support for NEW TLA714 and TLA720 mainframes
- Support for NEW TLA7Nx/Px 16 MB Deep Logic Analyzer Modules
- Hardware accelerated Waveform generation for the TLA7Nx/Px Logic Analyzer Modules
- Hardware accelerated search for the TLA7Nx/Px Logic Analyzer Modules
- Faster LA module data access
- Progress displays for Listing upgrade, Waveform upgrade, Searching upgrade and Saving data
- LA Setup Window's Channel Name Table is resizable. The Delete All Groups selection is now available
- Enhanced window placement: Cascade, Tile Horizontally and Tile Vertically
- The DSO Setup Window can now be maximized to be consistent with the other windows
- Symbol coloring
- High-level language (HLL) Source Code Support for OMF51
- Improved support for ELF/DWARF, ELF/STABS,and COFF symbol files
- Range and Pattern Symbol table color binding
- Can now use symbol file in use by another application (compiler usually)
- Source file finder dialog accepts huge file names
Version 2.0 -
- HLL Source Code Support
- Performance Analysis
- Enhanced Repetitive Acquisition Control with Memory Comparison
- TLA Programmatic Interface (TPI) for remote control using Microsoft COM/DCOM with support for advanced data analysis
- Faster UI performance
- New data window wizard
- Added Word Event to LA trigger and expanded number of IF-THEN clauses to 16
- Added binary format & additional delimiters to data export
- Added Print All to all data windows
- Enhanced Magnitude Mode in Waveform window
- Added "External LA Clock Source Idle" detection
Version 1.1 -
- TLA704 soft-power down
Installation Notes
When you purchase a new Logic Analyzer, the basic TLA Version 4.4 application software is installed at the factory. Some software packages must be installed separately, such as microprocessor and bus support packages. For information about these packages, refer to their associated documentation or contact your local Tektronix account manager.
Do not install the TPI Client Software on the logic analyzer. The TPI Client Software is for installation on a separate, remote PC that will control the logic analyzer using the TLA Programmatic Interface (TPI). See the TPI online help on your TLA logic analyzer for more information.
File Compatibility
Saved system files which include setup and data information are "forward-compatible" with each release of TLA applications software, i.e., a V1.1 saved system file will properly load on logic analyzers with Version 4.4 software. However, saved system files are not "backwards-compatible," that is, a Version 4.4 saved system file will not load on a logic analyzer with Version 3.2 or earlier software.
Module Firmware Compatibility
After upgrading the TLA applications software in your mainframe, you will often be required to upgrade the firmware in your logic analyzer, pattern generator, and digitizing oscilloscope modules. However, while you are not required to re-run any performance verification/adjustment procedures, you are encouraged to run both self-calibration and extended diagnostics on all mainframes and instrument modules that have been upgraded. Please note that all instrument modules to be used in a TLA mainframe with Version 4.4 application software must have the instrument module firmware upgraded; otherwise, the TLA application software will not recognize the instrument module. The firmware process, however, is easy-to-do and takes about 5 minutes per instrument module. All of the firmware images are part of each TLA application software release.
TLA Backup Media
Each logic analyzer comes standard with the Microsoft Windows 2000 Professional Operating System and TLA applications software preloaded on the hard disk. CD-ROMs for both Windows and the Version 4.4 TLA applications software are also provided as backup media.
The TLAVu and PatGenVu offline data viewers are on the backup media CD-ROMs for installation on any Windows 2000/XP PC.
Please contact your local Tektronix account manager for complete instructions and information on ordering a TLA7UP Field Upgrade Kit. Have the model number of your TLA mainframe ready when you call.
TLA7UP
TLA700 Series Logic Analyzer Field Upgrade Kit.
TLA7UP Option 09 - includes TLA720 Fan Controller Module, TLA7UP Mainframe Field Upgrade Kit Instruction Manual.
Option 09 - TLA720 Benchtop Mainframe Upgrade, S/N B0199999 or lower, Required for TLA7XM.
TLA7UP Option 12 - includes two 256 MB SODIMM's, Replaceable Hard Disk cartridge with 40 GB Hard Disk, jumpers, Front panel trim ring removal tool, TLA7UP Mainframe Field Upgrade Kit Instruction Manual.
Option 12 - For TLA715, 512 MB DRAM with Replaceable Fixed Hard Disk, Second Internal Fixed Hard Disk and Spare Replaceable Hard Disk.
TLA7UP Option 15 - includes an iView external oscilloscope interface with SMB-to-BNC adapter, TLA7UP Mainframe Field Upgrade Kit Instruction Manual.
Option 15 - iView External Oscilloscope Cable for TLA Family of Logic Analyzers.
TLA7UP Option 16 - includes TLA715 controller, two 256 MB SODIMM's, Replaceable Hard Disk cartridge with 40 GB Hard Disk, flat panel trim ring removal tool, jumpers, TLA715 controller card cover, TLA7UP Mainframe Field Upgrade Kit Instruction Manual.
Option 16 - Controller Upgrade for TLA714 Mainframe. Requires TLA7UP Option 37.
TLA7UP Option 17 - includes TLA721 controller with 512 MB RAM installed, Replaceable Hard Disk cartridge with 40 GB Hard Disk, Wheel Mouse, TLA7UP Mainframe Field Upgrade Kit Instruction Manual.
Option 17- Controller Upgrade for TLA720 Mainframe. Requires TLA7UP Option 37.
TLA7UP Option 20 - includes CD-RW Drive for TLA714/720 and TLA715/721 Logic Analyzer Mainframes, RecordNow Max, flat-panel trim ring removal tool, TLA7UP Mainframe Field Upgrade Kit Instruction Manual.
Option 20 - CD-RW drive for TLA714/720 and TLA715/721 Logic Analyzer Mainframes.
TLA7UP Option 35 - includes Version 4.4 TLA Application SW for a TLA714/720, Windows 2000 Professional, EasyRestore license, Win2k Pro license, Win2k Pro certificate of authenticity, CheckIt Utilities license, TLA Family User Manual, TLA7UP Mainframe Field Upgrade Kit Instruction Manual, jumpers, TLA Mouse Pad, SW Revision labels.
Option 35 - For TLA714/720, Version 4.4 TLA Application Software and Windows 2000 Professional Operating System.
TLA7UP Option 36 - includes Version 4.4 TLA Application SW, CheckIt Utilities license, TLA Family User Manual, TLA7UP Mainframe Field Upgrade Kit Instruction Manual, jumpers, TLA Mouse Pad, SW Revision labels.
Option 36 - For TLA714/715/720/721, Version 4.4 TLA Application Software.
TLA7Up Option 37 - includes Version 4.4 TLA Application SW for a TLA715/721 or TLA714/720 with a controller upgrade, Windows 2000 Professional, EasyRestore license, Win2k Pro license, Win2k Pro certificate of authenticity, CheckIt Utilities license, TLA Family User Manual, TLA7UP Mainframe Field Upgrade Kit Instruction Manual, jumpers, TLA Mouse Pad, SW Revision labels.
Option 37 - TLA Application Software and Windows 2000 Professional Operating System for TLA715/721 or TLA714/720 with Controller Upgrade (TLAUP Option 16 or Option 17).
Option IF - Tektronix Service Center Installation.
Option IN - On-Site Installation Service.
Option PF - PowerFlex utility software.
TLA7UP Mainframe Field Upgrade Kit User Manual - Order 071-0865-xx.
If you have any questions about what upgrades you may need, or any applications or technical questions, you can contact the Tektronix Technical Support Center at: www.tektronix.com/contact