Download
Download

Download Manuals, Datasheets, Software and more:

DOWNLOAD TYPE
MODEL or KEYWORD

Product Support and Downloads

Welcome to Tektronix Product Support

While we’re happy to “talk tech” with you all day long, we know you’re in a hurry. So we’ve made it easy for you to download manuals, datasheets and software for all our current products, and many discontinued products as well. Just tell us which product you’re using, and we’ll show you everything we have.

The product model you have chosen is currently available for purchase. The following support information is available.

  • FAQS FAQ ID

    69601

    69616

    69591

    70966

    70891

    72036

    71456

    70976

    70996

    72026

    72011

    70951

    69596

    70956

    70186

    70896

    71906

    70881

    69636

    71926

    69621

    70876

    70991

    70911

    69606

    70916

    71731

    70886

    70971

    70986

    71671

    71316

    69911

    70931

    70901

    70941

    69626

    71871

    70936

    70906

    69631

    70946

    70926

    71726

    71221

    70921

    70961

    69611

    69641

    69556
    How do I calculate the resistance accuracy of the Model 2450 on the 2 Ohm and greater than 200M ohm range?
    Below are the numbers to use for calculating the accuracy of 2 ohm and 200M ohms ranges. Since these particular ranges are only realized by using MANUAL OHMS, the below source values and measure values were used. In manual ohms the user can choose wh
    470646
    What is Source Readback?
    You can set the instrument to record and display the voltage or current of the configured source value or the actual source value. When you use the configured source value, the instrument records and displays the value that was configured. When you u
    775816
    Where can I find the battery discharge script for Model 2450?
    Answer: The battery discharge script is on the tek forum. Here is the link. https://forum.tek.com/viewtopic.php?f=66&t=140141  
    729071
    How do I create an I-V Characterizer test that uses more than one SMU Instrument?
    Use the “Instruments” button in the I-V Characterizer app toolbar to access the “Add Channels” button to add more SMU instruments to your test.   You can add up to 4 SMU instruments in a single I-V Characterizer app.
    470091
    Do you have a SCPI Sequence for 100V @ 10A on Model 2461 SMU?
    Here is a sequence of SCPI commands the configure the Model 2461 SMU to output a 100V pulse up to 10A.   RST SYSTem:CLEar TRACe:MAKE "PulseBuffer", 50 SOURce:FUNCtion CURRent SOURce:CURRent:RANGe:AUTO OFF SOURce:CURRent:RANGe 1 SOURce:CURRent 0 SOU
    773831
    What is a low cost test fixture to perform stable and accurate current measurements below 1nA?
    Taking stable and accurate current measurements below 1nA requires a guard shield (Faraday cage) as per the below excerpt from the 6430 reference manual (Figure 1). It was desired to measure currents below 1pA. A 1T resistor was selected. The voltage
    781711
    What happens in High Capacitance mode in Model 2450 SMU?
    The SMU is a closed loop control device to maintain a steady force value on your DUT. The capacitance of your cabling and DUT and the current sense resistor (internal to the SMU) form a pole. For certain combinations of current sense resistor and ext
    775821