MSO/DPO4000B Mixed Signal Oscilloscope

The MSO/DPO4000B Series is being replaced by the MDO4000C Series. The MDO4000C can be configured as a digital phosphor oscilloscope (DPO) or as a mixed signal oscilloscope (MSO) to suit your application.
Learn more about the MDO4000C Series.

Feature-rich tools for debugging mixed signal designs.

Offering up to 1 GHz bandwidth and 5 GS/s sample rate, the MSO/DPO4000B Mixed Signal Oscilloscope Series delivers the performance you need to see fast-changing signal details. With as many as 20 channels, you can analyze analog and digital signals with a single instrument. Combine that with automated serial and parallel bus analysis, innovative Wave Inspector® controls, and automated power measurements, and the MSO/DPO4000B Series provides the feature-rich tools you need to simplify and speed debug of your complex design.

Looking for the MSO4000B Series at 100 MHz, 350 MHz, 500 MHz or 1 GHz? You will find their replacements in the MDO4000B Series. These oscilloscopes have a built-in spectrum analyzer at no additional cost. Learn more about these products today.

Features

Benefits

2 or 4 analog and 16 digital channels Analyze analog and digital signals on a single instrument for system-level troubleshooting of complex designs.
Digital phosphor display Quickly discover glitches and infrequent events with a greater than 340,000 wfm/s waveform capture rate and intensity-graded display.
Complete set of triggers Rapidly capture signal anomalies with over 125 available trigger combinations, including setup/hold, serial packet content and parallel data.
Wave Inspector® controls Easily search, mark and navigate long record lengths to find all occurrences of your event.
Automated Measurements Simplify analysis of your device with 42 automated measurements, FFT analysis, measurement statistics, waveform histograms, and advanced waveform math.
Parallel bus triggering and analysis (MSO Series) Quickly debug your parallel bus with automated trigger, decode and search. Capture fast transitions with timing resolution up to 60.6 ps.
Serial triggering and analysis (optional) Quickly debug common serial buses with automated trigger, decode and search – I2C, SPI, USB, Ethernet, CAN, LIN, FlexRay, RS-232/422/485/UART, I2S/LJ/RJ/TDM, and MIL-STD-1553.
Power analysis (optional) Achieve fast, accurate results with integrated automated power measurements.
Low-capacitance passive voltage probing Four probes with industry-best 4pF capacitive loading and up to 1 GHz bandwidth are included standard to ensure accurate measurements

 

Low Voltage Single Ended Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TAP1500 Active Probe: 1.5 GHz, 10X, Single-ended, TekVPI Configure & Quote
Current Probe
Datasheet LinkProbeDescriptionConfigure and Quote
TCP0150 Current Probe: 20 MHz, 5 mA to 212 A, AC/DC, TekVPI Configure & Quote
High Voltage Differential Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TDP0500 Differential Probe: 500 MHz, 5X/50X, +/- 42V, TekVPI Configure & Quote
TDP1000

Differential Probe: 1 GHz, 5X/50X, +/- 42V, TekVPI

Configure & Quote
THDP0100 Differential PROBE; 100 MHZ TekVPI DIFFERENTIAL HIGH VOLTAGE PROBE Configure & Quote
THDP0200 Differential PROBE; 200 MHZ TekVPI DIFFERENTIAL HIGH VOLTAGE PROBE Configure & Quote
TMDP0200 Differential PROBE; 200 MHZ TekVPI DIFFERENTIAL MEDIUM VOLTAGE PROBE;TMPD0200 Configure & Quote
Isolated Measurement Systems
Datasheet LinkProbeDescriptionConfigure and Quote
TIVM1

Differential Probe; 1 GHZ, 1X/5X/10X/20X/50X, +/- 50V, TekVPI, 3 Meter Cable

Configure & Quote
TIVM1L

Differential Probe; 1 GHZ, 1X/5X/10X/20X/50X, +/- 50V, TekVPI, 10 Meter Cable

Configure & Quote
Passive Probe
Datasheet LinkProbeDescriptionConfigure and Quote
TPP0502

Passive Probe: 500 MHz, 2X, TekVPI

Configure & Quote
TPP1000

Passive Probe: 1 GHz, 10X, TekVPI

Configure & Quote
High Voltage Single Ended Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TPP0850

High Voltage Probe: 800 MHz, 50X, 2.5 kV, Single-ended, TekVPI

Configure & Quote
Data SheetAccessoryDescription
ACD4000B Soft Carrying Case
HCTEK54 Hard Carrying Case
NEX-HD2HEADER NEXUS TECHNOLOGY, INC. MICTOR TO HEADER PIN ADAPTER
RMD5000 Rackmount Kit
TPA-BNC Probe adapter from TekProbe-BNC to TekVPI
Data SheetSoftware Package / Software OptionDescriptionConfigure and Quote
DPO4USB Application Module: USB Serial Triggering and Analysis (USB2.0 LS, HS, FS) Configure & Quote
DPO4VID Application Module: HDTV and Custom Video Triggering Configure & Quote

Gold Care

 
Data Sheet Plan Description Shop Online or Learn More
View Datasheet G3

Gold Care Service  – 3 Years (Expedited repair for all product failures, access to loaner, priority customer service)

Learn More
View Datasheet G5

Gold Care Service – 5 Years (Expedited repair for all product failures, access to loaner, priority customer service)

Learn More

Silver Care (Extended Warranty)

 
Data Sheet Plan Description Shop Online or Learn More
View Datasheet R5

Silver Care Repair Service – 5 Years (Includes warranty)

Learn More
View Datasheet SILV600

Silver Care Repair Service Package – 5 Years (Includes warranty)

Learn More

Calibration

 
Data Sheet Plan Description Shop Online or Learn More
View Datasheet C3

Calibration Service – 3 Years

Learn More
View Datasheet C5

Calibration Service – 5 Years

Learn More

 

TitleType
Making MicroVolt Biomedical Measurements

Refined biomedical measurements easily and inexpensively.

Technical Brief
MSO/DPO4000B Series vs. Agilent MSO/DSO3000 X-Series

Side-by-side comparison on important features like serial triggering and decode, measurements and waveform math, digital debug with MSO, and more.

Competitive
3000 X-Series vs. MSO/DPO4000B Series True Cost of Your Scope

Tektronix bench oscilloscopes are packed with innovative features to help you get your job done faster, built right into the scope. And, with a comprehensive set of probes and accessories included standard, you can start testing right out of the box. When comparing oscilloscopes, don’t forget to look at the "hidden" costs to get the configuration you need.

Competitive
Capacitance and Inductance Measurements Using an Oscilloscope and a Function Generator

Don't have an LCR meter in your lab? Want to demonstrate the behavior of capacitors and inductors under sinusoidal stimulus? See how a DPO4104 scope and an AFG3000 function generator can help you get your results.

Application Note
MDO4000B Series vs. Agilent/Keysight MSOX4000A Series

When comparing oscilloscopes, check the details of the operation and look for “hidden” costs.

Competitive
Probing Techniques for Accurate Voltage Measurements on Power Supplies with Oscilloscopes

This application note explains probing techniques for making high-quality measurements on power supplies. It covers the use of passive and differential probes with emphasis on applications in power conversion circuits.

Application Note
Testing a New Switch Mode Power Supply Design Poster

This poster gives an overview of key measurements on a new switch mode power supply (SMPS) design, from initial startup, to optimizing switching and magnetic losses, to validating overall performance  and getting ready for regulatory compliance.

Poster
How to Minimize Probe Loading with Low Capacitance Probes

This application note describes how the high bandwidth, low capacitance passive voltage Tektronix probes bridge the gap between general purpose passive probes and higher cost active probes.

Application Note
Debugging Serial Buses in Embedded System Designs

Learn the basics of the hardware protocols of the most common serial buses. Find out how to use the protocol trigger, decode and search capabilities of oscilloscopes to solve serial bus integration and debug challenges.

Application Note
How to Use a Mixed Signal Oscilloscope to Test Digital Circuits

Learn more about verifying and debugging complex designs with a Mixed Signal Oscilloscope (MSO).

Application Note
Downloads
Download

Download Manuals, Datasheets, Software and more:

Go to top