Keithley Precision DC and AC+DC Low Noise Current Sources

Keithley Precision DC and AC+DC Low Noise Current Sources

The Model 6220 DC Current Source and Model 6221 AC and DC Current Source combine ease of use with exceptionally low current noise. Low current sourcing is critical to applications in test environments ranging from R&D to production, especially in the semiconductor, nanotechnology, and superconductor industries. High sourcing accuracy and built-in control functions make the Models 6220 and 6221 ideal for applications like Hall measurements, resistance measurements using delta mode, pulsed measurements, and differential conductance measurements.

Thumbnail

Keithley Ultra-sensitive Current Sources Series 6200

Features

Benefits

1014Ω output impedance Ensures stable current sourcing into loads with a wide range of output impedances.
65000-point source memory Allows executing comprehensive test current sweeps directly from the current source.
Output voltage compliance from 0.1V to 105V in 10mV steps Prevents potential damage to devices susceptible to overvoltage.
Source AC currents from 4pA to 210mA peak to peak (6221) Supports AC characterization of components and materials.
10MHz output update rate (6221) Generates smooth sine waves up to 100kHz.
Built-in standard and arbitrary waveform generators with 1mHz to 100kHz frequency range (6221) Supports use as a complex programmable load or sensor signal and for noise emulation.
Programmable pulse widths as short as 5μs (6221) Limits power dissipation in fragile, low power components and supports pulsed I-V measurements down to 50μs when used with the Model 2182A Nanovoltmeter.
Reconfigurable triax output Simplifies matching the application’s guarding requirements.

Models

Model Current Resistance Sweep Points PC Interface Internal Waveform Generator List Price
6220 ± (100fA – 100mA)

10nΩ to 200MΩ (requires 2182A)

65,536 (64k) GPIB, RS-232 -
-
Configure & Quote
6221 ± (100fA – 100mA)

10nΩ to 200MΩ (requires 2182A)

65,536 (64k) GPIB, RS-232, Ethernet 1mHz-100kHz with 10M samples/s output update rate
-
Configure & Quote
Model 6220
CurrentResistanceSweep Points
± (100fA – 100mA)

10nΩ to 200MΩ (requires 2182A)

65,536 (64k)
PC Interface
GPIB, RS-232
Model 6221
CurrentResistanceInternal Waveform Generator
± (100fA – 100mA)

10nΩ to 200MΩ (requires 2182A)

1mHz-100kHz with 10M samples/s output update rate
Sweep PointsPC Interface
65,536 (64k)GPIB, RS-232, Ethernet
Model Current Resistance Sweep Points PC Interface Internal Waveform Generator List Price
6220 ± (100fA – 100mA)

10nΩ to 200MΩ (requires 2182A)

65,536 (64k) GPIB, RS-232 -
-
Configure & Quote
6221 ± (100fA – 100mA)

10nΩ to 200MΩ (requires 2182A)

65,536 (64k) GPIB, RS-232, Ethernet 1mHz-100kHz with 10M samples/s output update rate
-
Configure & Quote
Model 6220
CurrentResistanceSweep Points
± (100fA – 100mA)

10nΩ to 200MΩ (requires 2182A)

65,536 (64k)
PC Interface
GPIB, RS-232
Model 6221
CurrentResistanceInternal Waveform Generator
± (100fA – 100mA)

10nΩ to 200MΩ (requires 2182A)

1mHz-100kHz with 10M samples/s output update rate
Sweep PointsPC Interface
65,536 (64k)GPIB, RS-232, Ethernet
Data SheetAccessoryDescription
2000-BENCHKIT MULTI MODEL BENCH CONVERSION KIT
237-ALG-15 LOW NOISE TRIAX CABLE 15M(50FT)
237-ALG-2 LOW NOISE TRIAX CABLE
The webinar covers semiconductor and other material characterization using Hall Effect and van der Pauw measurements for calculating sample resistivity and mobility among other parameters as well as…
0h 31m 10s
Characterization of New Materials and Devices Nanotechnology, Printed and Bio Electronics, and Energy
0h 34m 2s
Characterizing Nanoscale Devices with Differential Conductive Measurements
With appropriate instrumentation, the four-wire source current/measure voltage method is a great improvement over older differential conductance measurements, which are slow, noisy, and complex.  The new technique's single sweep shortens hours of data…
Technical Article 11 Nov 2018
High Impedance Semiconductor Resistivity and Hall Effect Test Configurations
Brochure 11 Nov 2018
Install v2.7 of the Free Example Software for the Models 6220/6221.

Part number: 6220-EXMPL-2.7
Application
Keithley I/O Layer - version C07 (Windows 8, 7, Vista, and XP Compatible)

Part number: KIOL-850C07
Application
Keithley Instruments Safety Precautions Safety Precautions PA
This document contains safety information for Keithley Instruments products.
Part number: 071341102
User
Model 6220 DC Current Source Model 6221 AC and DC Current Source User's Manual
User's Manual, Rev. B for the Model 6220 DC Current Source and the Model 6221 AC and DC Current Source.
Part number: 622X-900-01B
Primary User
Model 6220 DC Current Source Model 6221 AC and DC Current Source Reference Manual
Reference Manual, Rev. B for the Model 6220 DC Current Source and the Model 6221 AC and DC Current Source
Part number: 622X-901-01B
User
622x Native LabView 2009 Driver version 1.0.0 - Project Style

Part number: 622X-LV-1.0.0
Driver
Model 6220 DC Current Source and Model 6221 AC and DC Current Source
Datasheet
6220/6221 Firmware Revision A05

Part number: 6221-801A05
Firmware
6220/6221 Firmware revision A04

Part number: 6221-801A04
Firmware
6220/6221 Firmware Revision D03

Part number: 6221-801D03
Firmware
Flashwizard version C12 (Windows 7, Vista, XP, Win2K, NT, ME, 98 Compatible)

Part number: FLASH-WIZARD-C12
Firmware
6220/6221 IVI Driver for Visual Basic (VB), VC/C++, Labview (LV) and LabWindows CVI, Rev. B01.1 (6.4Mb) - Requires Installation of Keithley I/O Layer (KIOL-850)

Part number: 622X-855B011
Driver
#2611 Low-Level Pulsed Electrical Characterization with the Model 6221/2182A Combination
This application note describes how to use the Keithley 6221 Precision AC/DC Current Source together with the 2182A Nanovoltmeter to perform low-level pulsed electrical characterization on devices where continuous DC characterization is not possible.
Application Note 08 Aug 2017
Downloads
Download

Download Manuals, Datasheets, Software and more: