With wide voltage and current ranges, the PWS4000 Programmable Power Supply Series makes a versatile addition to your bench. A basic voltage accuracy of 0.03% and less than 5 mVp-p noise means you can be confident in the power supply's output value. List mode and a USB port for remote programming accelerate complex test development. The PWS4000 Power Supply Series generates the power you need for your application – quickly and precisely.
![]()
Features |
Benefits |
| Linear regulation | Deliver clean power - with less than 5 mVp-p ripple and noise - to your device. |
| Better than 0.03% basic voltage accuracy | Be confident in your power supply’s output value with 0.03% voltage and 0.05% current basic accuracy. |
| Up to 72 V output voltage | Generate the power you need for a wide variety of applications with a single power supply. |
| Overvoltage protection (OVP)and maximum voltage setting | Protect your device under test from accidental damage with integrated OVP circuit and microprocessor-controlled maximum voltage setting. |
| Remote sense inputs | Deliver accurate voltage to your device under test by eliminating the effect of voltage drop in your lead wires. |
| List mode | Define up to 7 custom test sequences, each with up to 80 voltage and current steps, with the built-in list mode. |
| 40 setup memories | Simplify complex tests by saving your setup to an internal setup memory. Next time you need to run the test, simply recall that setting. |
| Numeric keypad | Quickly set precise voltage and current values with the direct-entry keypad. |
| Bright display | See your power supply’s meter readings and limits with a single glance; a bright display provides excellent readability. |
| User-definable password | Prevent unwanted adjustments during critical tests by locking the front panel of your power supply. |
| PC Connectivity | Easily connect to a personal computer using the USB device port; Use your preferred programming environment or included NI LabVIEW SignalExpress software to control your power supply remotely. |
Models
| Model | Description | Number of Outputs | Maximum Voltage | Maximum Current | Connectivity | List Price |
|---|---|---|---|---|---|---|
| PWS4205 | Power Supply, 20 Volts, 5 Amps | 1 | 20V | 5A | USB | - |
| PWS4323 | Power Supply, 32 Volts, 3 Amps | 1 | 32V | 3A | USB | - |
| PWS4721 | Power Supply, 72 Volts, 1.2 Amps | 1 | 72V | 1.2A | USB | - |
| PWS4305 | Power Supply, 30 Volts, 5 Amps | 1 | 30V | 5A | USB | - |
| PWS4602 | Power Supply, 60 Volts, 2.5 Amps | 1 | 60V | 2.5A | USB | - |
Power Supply, 20 Volts, 5 Amps
120VPower Supply, 32 Volts, 3 Amps
132VPower Supply, 72 Volts, 1.2 Amps
172VPower Supply, 30 Volts, 5 Amps
130VPower Supply, 60 Volts, 2.5 Amps
160V| Model | Description | Number of Outputs | Maximum Voltage | Maximum Current | Connectivity | List Price |
|---|---|---|---|---|---|---|
| PWS4205 | Power Supply, 20 Volts, 5 Amps | 1 | 20V | 5A | USB | - |
| PWS4323 | Power Supply, 32 Volts, 3 Amps | 1 | 32V | 3A | USB | - |
| PWS4721 | Power Supply, 72 Volts, 1.2 Amps | 1 | 72V | 1.2A | USB | - |
| PWS4305 | Power Supply, 30 Volts, 5 Amps | 1 | 30V | 5A | USB | - |
| PWS4602 | Power Supply, 60 Volts, 2.5 Amps | 1 | 60V | 2.5A | USB | - |
Power Supply, 20 Volts, 5 Amps
120VPower Supply, 32 Volts, 3 Amps
132VPower Supply, 72 Volts, 1.2 Amps
172VPower Supply, 30 Volts, 5 Amps
130VPower Supply, 60 Volts, 2.5 Amps
160V| Data Sheet | Accessory | Description |
|---|---|---|
| RMU2U | Rackmount Kit |
Silver Care (Extended Warranty)
| Data Sheet | Plan | Description | Shop Online or Learn More |
|---|---|---|---|
| View Datasheet | R5 |
Silver Care Repair Service – 5 Years (Includes warranty) |
Learn More |
| View Datasheet | SILV100 |
Silver Care Repair Service Package – 5 Years (Includes warranty) |
Learn More |
Calibration
| Data Sheet | Plan | Description | Shop Online or Learn More |
|---|---|---|---|
| View Datasheet | C3 |
Calibration Service – 3 Years |
Learn More |
| View Datasheet | C5 |
Calibration Service – 5 Years |
Learn More |
| Series 2200 and Series PWS4000 Single Output Power Supplies Adjustment Program Series 2200 and Series PWS4000 Single Output Power Supplies Adjustment Program Part number: PC2200-4000_ADJ | Application | |
| FCA3000, FCA3100, MCA3000, DMM4000, PWS2000, and PWS4000 Series This document contains instructions for mounting a supported bench instrument onto the RMU2U rackmount tray, for installation in a standard 19-inch equipment rack. Supported instruments include PWS2000 and PWS4000 Series Power Supplies, FCA3000 and… Part number: 075101800 | Field Install Instructions | |
| Choosing the Right Power Supply for Accurate Power Delivery Choosing the right power supply for your application requires a good understanding of how they are specified. In this application note, learn how to interpret linear power supply specifications like accuracy and resolution, load and line regulation and… Literature number: 3GT-25248-0 | Fact Sheet | 10 Nov 2018 |
| PWS4205, PWS4305, PWS4602, PWS4721 This document describes commands that can be used to remotely control the PWS4205, PWS4305, PWS4323, PWS4602, and PWS4721 power supplies. Part number: 077048103 | Programmer | |
| PWS4205, PWS4305, PWS4323, PWS4602, and PWS4721 This document contains the specifications and performance verification procedures for the instruments. Part number: 077048000 | Performance Verification | |
| PWS4205, PWS4305, PWS4602, PWS4721 This document describes commands that can be used to remotely control the PWS4205, PWS4305, PWS4323, PWS4602, and PWS4721 power supplies. Part number: 077048102 | Programmer | |
| PWS4000 Series Linear DC Power Supplies This document helps customers with data security concerns to sanitize or remove memory devices from the PWS4000 Series Linear DC Power Supplies. These products have data storage (memory) devices and these instructions tell how to clear or sanitize the… Part number: 077064000 | Declassification | |
| Tektronix Bench Instruments This document describes how to install software, drivers, and files to use LabVIEW SignalExpress Tektronix Edition software to remotely acquire data and measurements from supported Tektronix Bench Instruments. Part number: 077052700 | Field Install Instructions | |
| Power Supplies E-Guide | Selection Guide | 09 Nov 2018 |
| FCA3000 and FCA3100 Series, MCA3000 Series, DMM4000 Series, PWS2000 and PWS4000 Series, AFG2021 This document contains instructions for mounting a bench instrument onto the RMU2U rackmount tray, for installation in a standard 19-inch equipment rack. Supported instruments include PWS2000 and PWS4000 Series Power Supplies, FCA3000 and FCA3100 Series… Part number: 075101802 | Field Install Instructions | |
| Power Supply Selection Guide Power Supply Selection GuidePower Supply Selection Guide | Selection Guide | 09 Nov 2018 |
| DC Power Supply Technical Information | Technical Brief | 09 Nov 2018 |
| PWS4205, PWS4305, PWS4602, PWS4721 This manual contains information about the operation of the PWS4205, PWS4305, PWS4323, PWS4602, and PWS4721 power supplies. Part number: 071276101 | Primary User | |
| Programmable DC Power Supplies Tektronix PWS4000 SeriesA wide current and voltage range, and flexible features, make the PWS4000 Power Supply Series a versatile addition to your bench. With 0.03% basic voltage accuracy and 0.05% basic current accuracy, you can be confident in the power supply’s output value.… Literature number: 3GW-25253-5 | Datasheet | |
| Selector Guide - General Purpose Power Supplies, Special Purpose Power Supplies, and Electronic Loads Literature number: 1KW-60035-2 | Product Selector Guide | 09 Nov 2018 |