How do I find the IP address for a 2450-NFP?

Your TCP/IP v4 settings should be set to


This FAQ applies to:
2450-NFP
468846
What are the current shunt resistors in the current measurement function?

There are two shunt resistors.

One is  5.1 ohms for the 20mA range and the other is 0.1 ohms for the 100mA, 1A, and 3A ranges.


This FAQ applies to:
2700, 2700/7700, 2701, 2750
468841
Settings saved on Model 6517B when updating firmware.

Yes, settings can be saved using the foll


This FAQ applies to:
6517B
468411
Differences between TCP202 and TCP202A

Differences are:

1. The jaw size of TCP202 is 3.8 mm while the jaw opening for TCP202A is 5 mm.

2. The TCP202A is rated for 150 V Cat on bare wire.


This FAQ applies to:
TCP202, TCP202A
468406
Size of TRCP current probe loops

The size of the loops are given in this document.


This FAQ applies to:
TRCP0300, TRCP0600, TRCP3000
468376
AFG3000B and AFG3000C differences

There at two differences.

1. The AFG3000C models the display was changed to TFT LCD which has a better viewing angle and brighter display.

2. And two new models were added. AFG3051C and AFG3052C.


This FAQ applies to:
AFG3011C, AFG3021B, AFG3021C, AFG3022B, AFG3022C, AFG3051C, AFG3052C, AFG3101C, AFG3102C, AFG3151C, AFG3152C, AFG3251C, AFG3252C
468371
Differences in the AFG1022 and AFG3022C

1. AFG1022 channel 2 is a continues signal only no modulation, burst, or sweep.  AFG3022C has full function on both channels.
2. AFG1022 Phasing of channel 1 and 2 is only available on for Sine wave below 1 MHz.  AFG3022C has phase control on any signal type and frequency.

This FAQ applies to:
AFG1022, AFG3022C

468361
How to Use a Link Partner in Testing with TDSET3 */
This FAQ applies to:
DPO4ENET, DPO5034B, DPO5054, DPO5054B, DPO5104, DPO5104B, DPO5204, DPO5204B, DPO70404, DPO70404B, DPO70404C, DPO7054, DPO70604, DPO70604B, DPO70604C, DPO70804, DPO70804B, DPO70804C, DPO7104, DPO71254, DPO71254B, DPO71254C, DPO71604, DPO71604B, DPO71604C, DPO72004, DPO72004B, DPO72004C, DPO72304DX, DPO72304SX, DPO72504DX, DPO7254, DPO73304DX, DPO73304SX, DPO7354, DPO75002SX, DSA70404, DSA70404B, DSA70404C, DSA70604, DSA70604B, DSA70604C, DSA70804, DSA70804B, DSA70804C, DSA71254, DSA71254B, DSA71254C, DSA71604, DSA71604B, DSA71604C, DSA72004, DSA72004B, DSA72004C, MSO5034, MSO5034B, MSO5054, MSO5054B, MSO5104, MSO5104B, MSO5204, MSO5204B, MSO70404, MSO70404C, MSO70604, MSO70604C, MSO70804, MSO70804C, MSO71254, MSO71254C, MSO71604, MSO71604C, MSO72004, MSO72004C, MSO72304DX, MSO72504DX, MSO73304DX, Opt. 5-SRENET, Opt. ET3, Opt. SR-ENET
468146
Could the number of analog channel be upgraded on the 5 series MSO?

No.  The analog channel count is fixed at the initial purchase.


This FAQ applies to:
MSO54, MSO56, MSO58
468131
What is the range of the logic threshold supported on the 5 and 6 Series MSO?

The logic threshold can be set between +/-40V with the TLP058 logic probe. Each individual digital channel can be set for its own threshold level.


This FAQ applies to:
MSO54, MSO56, MSO58, MSO64, TLP058