5.0 GHz Differential Probe with SMA Input
P7350SMA
The products on this datasheet are no longer being sold by Tektronix.
View Tektronix Encore for reconditioned test equipment.
Check support and warranty status for these products.
Features & Benefits
- <100 ps Rise Time (Guaranteed)
- 5.0 GHz Bandwidth (Typical)
- Dual SMA Inputs to Internal 50 Ω Termination Network
- Internal Differential Amplifier with High CMRR
- DC Bias Port for Common Mode Voltage Termination(LVPECL and CML bias capability)
- Good Differential Input Return Loss
- Low Input Skew
- Supplied with Low-loss Matched-delay Cables
- TekConnect™ Interface Preserves Signal Integrity to 10 GHz and Beyond to Meet Present and Future Bandwidth Needs
Applications
- Communications (Gigabit Ethernet, Fibre Channel, Infiniband)
- Semiconductor Characterization and Validation(PCI-Express, Serial ATA, IEEE 1394, USB 2.0, RAMBUS, DDR)
Tektronix brings you the first available high-speed differential SMA input probe. The P7350SMA provides a tool for measuring differential signals in a 50 Ω signaling environment. Before the introduction of the P7350SMA, most serial data compliance measurements required cabling a differential signal to two oscilloscope channels and applying waveform math to calculate the difference. By integrating a dual 50 Ω termination network and a differential amplifier in the probe head, the P7350SMA measures a differential signal pair on each channel of a multiple channel oscilloscope. Since many of the new high-speed serial data standards define differential signaling on multiple channels, the P7350SMA provides a more efficient measurement solution.
The P7350SMA probe architecture includes an input termination network, a differential buffer amplifier, and a common mode DC bias port. Since many differential data signals operate with a nonzero DC common mode voltage, the DC bias port allows for more flexible interfacing to these logic families. For applications requiring a common mode DC termination voltage, that voltage can be supplied to the P7350SMA DC bias port through a standard banana plug connector. For other differential measurement applications, such as AC-coupled and some DC-coupled high-frequency 8B/10B encoded data streams, the DC bias port can simply be left unconnected.
Input signals use SMA connectors to attach to the input termination network, implemented on a laser-trimmed hybrid circuit for signal fidelity and high-frequency response. The linear buffer amplifier converts the differential input signal to a single-ended output and drives the output signal down the probe cable at full bandwidth.
An active differential buffer amplifier in the probe head enables the P7350SMA probe to move the measurement interface from the oscilloscope front panel to the circuit-under-test. This can reduce the length of electrical interconnect cabling, which for multi-gigabit data signals also reduces frequency-dependent loss distortion in signal measurements. The P7350SMA is connected to an oscilloscope with the patented TekConnect Interface.
Characteristics
Rise Time -
<100 ps 10% - 90% (guaranteed)
<65 ps 20% - 80% (typical)
Bandwidth (Probe Only) - 5.0 GHz (typical)
Input - SMA
Attenuation - 6.25x
Differential Input Resistance - 100 Ω ±2%
Common Mode Input Resistance - 50 Ω ±1%
Input Skew - <1 ps
Differential Input Range - ±2.5 V (20 °C to 30 °C)
Common Mode Input Range - +6.25 V to -5 V
Maximum Termination Resistor Power - <0.5 W per side*1
Max Voltage (Nondestruct) - ±15 V (DC plus peak AC)
CMRR - >60 dB at DC, >55 dB at 1 MHz, >50 dB at 30 MHz, >30 dB at 1 GHz (typical)
*1 See manual for calculation
Differential Input Return Loss
Frequency |
Differential Return Loss |
---|---|
625 MHz (fundamental for 1.25 Gb/s) |
>20 dB |
1.25 GHz (fundamental for 2.5 Gb/s) |
>16 dB |
1.56 GHz (fundamental for 3.125 Gb/s) |
>14 dB |
2.50 GHz |
>12 dB |
3.125 GHz |
>10 dB |
Noise - Approximately 46 nV/root Hz
Interface - TekConnect
Cable Length - 1.2 m
Ordering Information
P7350SMA
5.0 GHz Differential SMA Probe for TekConnect Interface.
Includes
Product Name/Description |
Part Number |
Quantity |
---|---|---|
50 Ω Terminator |
015-0122-xx |
2 each |
Matched pair SMA Cables, 12 inches |
174-4866-xx |
1 set |
Banana Plug Shorting Strap |
012-1667-xx |
1 each |
BNC-M to SMA-F Adapter |
015-0572-xx |
1 each |
Cable Marker Set (5 colors) |
016-1886-xx |
1 each |
Wrist Strap |
006-3415-xx |
1 each |
Certificate of Traceable Calibration |
|
1 each |
Instruction Manual |
071-1264-xx |
1 each |
Recommended Accessories
Product Name/Description |
Part Number |
Quantity |
---|---|---|
SMA-M to SMA-M Adapter |
015-1011-xx |
2 each |
SMA Phase Adjuster Adapter |
015-0708-xx |
2 each |
BNC to Banana Adapter |
103-0090-xx |
1 each |
TekConnect Calibration Fixture |
067-0422-xx |
1 each |
Service Options
Opt. C3 - Calibration service 3 years
Opt. C5 - Calibration service 5 years
Opt. D1 - Calibration data report
Opt. D3 - Calibration data report 3 years (with Opt. C3)
Opt. D5 - Calibration data report 5 years (with Opt. C5)
Opt. R3 - Repair service 3 years
Opt. R5 - Repair service 5 years