Digital Sampling Oscilloscope

11801B

The products on this datasheet are no longer being sold by Tektronix.
View Tektronix Encore for reconditioned test equipment.
Check support and warranty status for these products.

Features & Benefits

  • DC to 50-GHz Bandwidth
  • 7-ps Rise Time
  • 8 Channels, Expandable to 136 (with SM-11)
  • 10-fs Sampling Interval (0.01 ps)
  • Modular Architecture
  • 200-kS/s Sample Rate
  • Dual Time Base
  • Nonvolatile Waveform and Setting Storage
  • FFT
  • Predefined Telecom Masks (Opt. 1T)
  • TDR
  • Automatic Measurements:
    • Jitter/Noise, Statistical
    • Histograms, Mask Testing
    • Pulse with Statistics
  • Programmable for ATE Applications
  • Comprehensive Waveform Processing
  • Color Display

Applications

  • Semiconductor Testing
  • TDR Characterization of Circuit Boards, IC Packages, and Cables

Sampling Heads

SD-14 - 2.5-GHz high-impedance (100 kilohm/0.475 pF) dual-channel probe sampler

SD-20 - 20-GHz single-channel loop-through head

SD-22 - 12.5-GHz dual-channel low-noise head

SD-24 - 20-GHz dual-channel TDR/sampling head

SD-26 - 20-GHz dual-channel sampling head

SD-30 - 40-GHz single-channel sampling head

SD-32 - 50-GHz single-channel sampling head

SD-42 - 6.4-GHz O/E converter (55-ps optical pulse response FWHM)

SD-46 - 20-GHz O/E converter (22-ps optical pulse response FWHM)

SD-51 - 20-GHz trigger head

Characteristics

Vertical System*1

Rise Time/Bandwidth - Determined by the sampling head used.

Vertical Resolution - 8-bit full screen (78 µV/LSB at 2 mV/div deflection factor).

Amplifier Gain Accuracy - ±1% of all settings.

Deflection Factors - 2 to 255 mV/div in 1 mV/div increments.

Offset Range - ±2 V.

*1 Vertical system specifications of 11801B with SD-14 nonapplicable. See 11800 Series Sampling Head specifications.

Horizontal System

Main and Window Time Base - 1 ps/div to 5 ms/div, settable to 1-2-5 sequence or in 1-ps increments.

Record Length - 512, 1024, 2048, 4096, and 5120 samples.

Windows - Any number of window records may be placed on any number of main records, up to a maximum of eight displayed traces. All window records have the same duration, but may be independently positioned on any main record. Windows may be set to automatically track a moving edge on the main record.

Maximum Sample Rate - 200 kS/s.

Trigger System*2

Trigger Bandwidth - 3 GHz.

Trigger Sensitivity -

DC, 1X ≤3 GHz: 100 mV.

AC, 1X 300 kHz to 3 GHz: 100 mV.

DC, 10X ≤3 GHz: 1 V.

AC, 10X 300 kHz to 3 GHz: 1 V.

Delay Jitter - 1.3 ps + 4 ppm of a position typical. 2.0 ps + 5 ppm of position maximum (RMS).

Internal Clock - 100 kHz (drives TDR, Internal Clock Output, and Calibrator).

Trigger Level Range - ±1.0 V (±10 V with 10X trigger attenuator activated).

Trigger Input Range - ±1.5 V (+15 V, 5 VRMS maximum with 10X).

Trigger Holdoff - 5 µs to 2.5 seconds.

*2 11801B external trigger requires 23-ns pretrigger or DL 11 Delay Lines to view trigger point (45.5 ns with Option 1M).

Measurement System

Waveform Processing Functions - Add, subtract, multiply, divide, absolute, average, differentiate, envelope, exponent, integrate, natural log, log, signum, square root, smoothing, and filter.

Measurement Set - Max, Min, Mid, Pk-Pk, Mean, RMS, Amplitude, Extinction Ratio, Overshoot, Undershoot, Noise*3, Rise, Fall, Spectral Magnitude, Spectral Frequency, THD, SNR, Frequency, Period, Prop Delay, Cross, Width, Phase, Duty Cycle, Jitter*3, Area+, Area-, and Energy. Measurements are constantly updated; mean and standard deviation available on all measurements.

Measurement Parameters - (Proximal, mesial, distal, and start/stop levels): May be set to absolute levels.

Cursors - Paired or split dots, vertical bars, and horizontal bars.

*3 Available only in statistical measurement mode.

TDR System (SD-24 only)

Combined TDR/Acquisition Reflected Rise Time - 35 ps or less

TDR Step Amplitude - Adjustable to ±250 mV (polarity of either step may be inverted)

Time Coincidence Between TDR Steps - Adjustable to less than 1 ps

Source Resistance - 50 ±0.5 ohm

Typical Aberrations (at ±250 mV Amplitude) -

10 ns to 20 ps before step: ±3% or less

Less than 300 ps after step: +10%, -5% or less

300 ps to 5 ns after step: ±3% or less

Elsewhere: ±1% or less

CRT And Display Features

CRT - 9-inch diagonal, magnetic deflection, vertical raster scan orientation. Color.

Colors - Eight-color default color set included; or colors are user-selectable from palette of 262,144 colors.

Video Resolution - 552 horizontal by 704 vertical displayed pixels.

Power Requirements

Line-Voltage Ranges - 90 to 132 VRMS, 180 to 250 VRMS

Line Frequency - 48 to 440 Hz

Maximum Power Consumption - 214 W

Environmental And Safety

Temperature -

Operating: 0 to +50 °C.

Nonoperating: -40 to +75 °C.

Humidity -

Operating and Nonoperating: up to 95% relative humidity, up to 50 °C. Per MIL-T-28800E, Type III, Class 5.

Altitude, Vibration, Shock Nonoperating, Bench Handling - Meets MIL-T-28800E, Type III, Class 5.

Electromagnetic Compatibility -

(with sampling heads or optional blank panels installed in all sampling head compartments)

Meets the Requirements of: MIL-STD-461B; FCC Part 15, subpart J, Class A; VDE 0871/6.78 Class B.

Safety - Listed UL 1244, CSA Bulletin 556B September 1973.

Time Base Accuracy - Typical Specifications

Range*4, 5 = Interval ≥ 1 ns - Base: 4 ps + Interval Specification: 0.004%*4 Interval + Position Specification 0.0004%*4 Position

Range*4, 5 = Interval = 100 ps - Base: 2.5 ps + Position Specification: 0.0004%*4 Position

Range*4, 5 = Interval ≤ 10 ps - Base: 1 ps + Position Specification: 0.0004%*4 Position

*4 For intervals <100 ps, the above holds for time/div ≤20 ps/div.

*5 For other intervals not listed above, linearly interpolate the cardinal points.

Physical Characteristics

11801B Cabinet -

Width: 448 mm (17.6 in.)

Height: 238 mm (9.4 in.)

Depth: 599 mm (23.6 in.)

Net Weight: 22.3 kg (49 lbs.)

Shipping Weight: 25.9 kg (57 lbs.)

SM-11 Cabinet -

Width: 448 mm (17.6 in.)

Height: 238 mm (9.4 in.)

Depth: 558 mm (22.0 in.)

Net Weight: 20.0 kg (44 lbs.)

Shipping Weight: 23.6 kg (52 lbs.)

11801B Rackmount -

Width: 483 mm (19.0 in.)

Height: 222 mm (8.8 in.)

Depth: 550 mm (21.6 in.)

Net Weight: 23.2 kg (51 lbs.)

Shipping Weight: 26.8 kg (59 lbs.)

SM-11 Rackmount -

Width: 483 mm (19.0 in.)

Height: 222 mm (8.8 in.)

Depth: 550 mm (21.6 in.)

Net Weight: 20.9 kg (46 lbs.)

Shipping Weight: 24.5 kg (54 lbs.)