Model Description Type From To m ft Use With:
237-ALG-2 Low Noise Input Triax 3-slot male triax Alligator clips (3) 2 6.6 Series 2200, Series 2600B, 4200-PA, 6220, 6221, 6482, 6487, 6514, 6517A, 6517B
2107-4 Input Cable Shielded twisted pair LEMO Copper spade lugs (4) 1.2 4 2182A
2290-5-SHV Input Cable Coax SHV Female SHV Female 3 10 2290-5, 2290-5-SHVBH
2290-5-MHV Input Cable Coax SHV Female MHV Male 3 10 2290-5
2290-10-SHV Input Cable Coax SHV Male SHV Male 3 10 2290-10, 2290-10-SHVBH
2290-10-SHVUC Input Cable Coax SHV Male Unterminated 3 10 2290-10
2290-INT-CABLE Interlock Cable 3-conductor 3-pin Unterminated 3.05 10 2290-5, 2290-10
2450-TRX-BAN Adapter Cable Triax 3-slot male triax Banana input jack 0.3 1 2450
2600-ALG-2 Low Noise Input Triax 3-slot male triax Alligator clips (3) 2 6.6 2635B, 2636B, 4200-PA
2651A-KIT-3 Cable Assembly Coax 2-pin plug 2-pin plug 3 10 2651A, 8011
3720-MTC-3 Mass Terminated Assembly Shielded multiple conductor D-sub female 78-pin D-sub male 3 10 3720, 3723, 3724
3721-MTC-3 Mass Terminated Assembly Shielded multiple conductor D-sub female 50-pin D-sub male 3 10 3721, 3730, 3731, 3740, 3750
3722-MTC-3 Mass Terminated Assembly Shielded twisted pair D-sub male 104-pin D-sub female 3 10 3722
4200-MTRX-1 Ultra Low Noise SMU triax Miniature male 3-slot male 1 3.2 4200A-SCS
4200-MTRX-2 Ultra Low Noise SMU triax Miniature male 3-slot male 2 6.5 4200A-SCS
4200-MTRX-3 Ultra Low Noise SMU triax Miniature male 3-slot male 3 9.8 4200A-SCS
4200-RPC-2 Cable Assembly Remote PreAmp DB15 DB15 2 6.5 4200-PA
4200-TRX-0.3 Ultra Low Noise PreAmp triax 3-slot male 3-slot male 0.3 1ft 4200-PA
4200-TRX-1 Ultra Low Noise PreAmp triax 3-slot male 3-slot male 1 3.2 4200-PA
4200-TRX-2 Ultra Low Noise PreAmp triax 3-slot male 3-slot male 2 6.5 4200-PA
4200-TRX-3 Ultra Low Noise PreAmp triax 3-slot male 3-slot male 3 9.8 4200-PA
4801 Low Noise Input Coax Male BNC Male BNC 1.2 4 6482, 6485
4803 Low Noise Cable Kit Coax Male BNC (10) Female BNC (5) 15.2 50 6482, 6485
6517B-ILC-3 Interlock Cable Shielded 4-pin Phoenix 4-pin DIN 1 3.3 6517B, 8009
7051-10 BNC Interconnect Coax BNC BNC 2015, 2016, 3390
7078-TRX-1 Low Noise Triax 3-slot male triax 3-slot male triax 0.3 1 2635B, 2636B, 6482, 6487, 6514, 6517A, 6517B, 7072, 7174A
7078-TRX-3 Low Noise Triax 3-slot male triax 3-slot male triax 0.9 3 2635B, 2636B, 6482, 6487, 6514, 6517A, 6517B, 7072, 7174A
7078-TRX-5 Low Noise Triax 3-slot male triax 3-slot male triax 1.5 5 2635B, 2636B, 6482, 6487, 6514, 6517A, 6517B, 7072, 7174A
7078-TRX-10 Low Noise Triax 3-slot male triax 3-slot male triax 3 10 2635B, 2636B, 6482, 6487, 6514, 6517A, 6517B, 7072, 7174A
7078-TRX-12 Low Noise Triax 3-slot male triax 3-slot male triax 4 12 2635B, 2636B, 6482, 6487, 6514, 6517A, 6517B, 7072, 7174A
7078-TRX-20 Low Noise Triax 3-slot male triax 3-slot male triax 6.1 20 2635B, 2636B, 6482, 6487, 6514, 6517A, 6517B, 7072, 7174A
7705-MTC-2 Mass Terminated Assembly Twisted pair (25) D-sub male D-sub female 2 6.6 7703, 7705, 7707, 7709
CA-18-1 Shielded Coax Dual banana plug Dual banana plug 1.2 4 Binding post inputs
CA-19-2 RG58 RG58 BNC male BNC male 1.5 5 4200A-SCS
CA-126-1A Digital I/O Shielded DB25 male DB25 female 1.5 5 Series 2600B, Series 3700A
CA-404B RG188 Coax SMA male SMA male 6.5 2 4200A-SCS
CA-405B RG188 Coax SMA male SMA male 0.15 0.5 4200A-SCS
CA-406B RG188 Coax SMA male SMA male 0.33 1.08 4200A-SCS
CA-446A Cable Assembly Coax SMA male SMA male 3 9.8 4210-CVU
CA-447A Cable Assembly Coax SMA male SMA male 1.5 5 4210-CVU
CA-451A RG188 Coax SMA male SMA male 0.108 0.35 4200A-SCS
CA-452A RG188 Coax SMA male SMA male 0.203 8 in. 4200A-SCS
CA-557-1A Cable Assembly Multiple conductor 8-pin receptacle 8-pin receptacle 1 3.3 2651A, 8011
CA-557-2A Cable Assembly Multiple conductor 8-pin receptacle 8-pin receptacle 2 6.6 2651A, 8011
CA-557-3A Cable Assembly Multiple conductor 8-pin receptacle 8-pin receptacle 3 10 2651A, 8011
CA-558-2 Interlock Cable Twisted pair (2) 25-pin D-sub 3-pin 1, 2, 3 3.3, 6.6, 10 Series 2600B, 2657A
CA-559-0A Black Banana Jumper Jumper Banana Banana 0.102 4 in. 8010
CA-559-2A Red Banana Jumper Jumper Banana Banana 0.102 4 in. 8010
CA-560-0A Banana Plug Jumper Cable Jumper Banana Banana 0.203 8 in. 8010
CA-560-2A Banana Plug Jumper Cable Jumper Banana Banana 0.203 8 in. 8010
CA-561-0A Black Banana Jumper Jumper Banana Banana 0.203 8 in. 8010
CA-561-2A Red Banana Jumper Jumper Banana Banana 0.203 8 in. 8010
CA-562-0B Black Safety Banana Plug Jumper Cable Jumper Banana Banana 0.254 10 in. 8010
CA-562-2B Red Safety Banana Plug Jumper Cable Jumper Banana Banana 0.254 10 in. 8010
CA-563C BNC to Banana Jumper Jumper BNC Banana 0.241 9.5 in. 8010
CA-567-0A Black Banana Jumper Jumper Banana Banana 0.203 8 in. 8010
CA-567-2A Red Banana Jumper Jumper Banana Banana 0.203 8 in. 8010
CA-568-xA Protective Earth Ground Safety Eye lug Eye lug 0.3,0.45, 3 1, 1.5,10 8010
HV-CA-554-x 3kV Rated High voltage Triax Triax 0.5, 1,2, 3 1.6, 3.3,6.6, 10 8010, 2657A
HV-CA-571-3 High Voltage Triax Triax Unterminated 2657A
SC-9 Low Noise Coax Unterminated Unterminated Sold by the foot
SC-22 Low Noise Triax Unterminated Unterminated Sold by the foot CS-631
SC-182 Low Inductance Coax Unterminated Unterminated Sold by the foot 2302, 2303, 2303-PJ, 2304A, 2306, 2306-PJ
SHV-CA-553-x 3kV Rated High voltage Triax SHV 1, 3 3.3,10 2657A
LIV curves
 

237-ALG-2: Low noise triax cable (SC22) terminated with a 3-slot male triax connector on one end and 3 alligator clips on the other. 2 m (6.6 ft) length.
For use with: Series 2200, Series 2600B, 4200-PA, 6220, 6221, 6487, 6514, 6482, 6517A, 6517B

LIV curves
 

2107-4: Low-Thermal Input Cables with Spade Lugs: An input cable terminated with a LEMO connector on one end and four copper spade lugs on the other.1.2 m (4 ft) length.
For use with: 2182A, Series 2200

2290-5-MHV: 3 m (10 ft) of RG-8A/U coaxial cable terminated with a SHV female connector on one end and a MHV male connector on the other end. Maximum operating voltage is 5000 Vrms. Characteristic cable impedance is 50 Ω.
For use with: 2290-5

2290-5-SHV: 3 m (10 ft) of RG-8A/U coaxial cable terminated with a SHV female connector on both ends. Maximum operating voltage is 5000 Vrms. Characteristic cable impedance is 50 Ω.
For use with: 2290-5

LIV curves
 

2651A-KIT-3: High current, low impedance, coaxial cable assembly. 3 m (10 ft).
For use with: 2651A, 8011

LIV curves
 

3720-MTC-3: 78-pin D-sub female to 78-pin D-sub male cable. 3 m (10 ft) length.
For use with: 3720, 3723, 3724

LIV curves
 

3721-MTC-3: 50-pin D-sub female to 50-pin D-sub male cable. 3 m (10 ft) length.
For use with: 3721, 3730, 3731, 3740, 3750

LIV curves
 

3722-MTC-3: 104-pin D-sub male to 104-pin D-sub female cable. 3 m (10 ft) length.
For use with: 3722

LIV curves
 

4803 Low Noise Cable Kit: Includes 15 m (50 ft) of low noise coax cable, 10 male BNC connectors, and 5 female BNC chassis-mount connectors.
For use with: 6482, 6485

LIV curves
 

6517B-ILC-3 Interlock Cable: Designed to connect the interlock of the 6517B with the 8009 test fixture. Configuring the 6517B with the 8009 test fixture results in all the electrode constants already being programmed into the unit.
For use with: 6517B Electrometer, 8009

LIV curves
 

7051-10: General purpose BNC to BNC cable (G-58C). 3 m (10 ft).
For use with: 2015, 2016, 3390, 7711, some instrument external trigger I/O lines

LIV curves
 

CA-406B: 33 cm (13 in) RG188 coax cable terminated with an SMA male plug on each end, 50 Ω impedance.
For use with: 4200A-SCS

LIV curves
 

CA-446A: 3 m (9.8 ft) coax cable terminated with an SMA male plug on each end, 100 Ω impedance.
For use with: 4210-CVU

LIV curves
 

CA-447A: 1.5 m (4.9 ft) coax cable terminated with an SMA male plug on each end, 100 Ω impedance.
For use with: 4210-CVU

LIV curves
 

CA-562-0B and CA-562-2B: Safety banana to banana jumper (254mm).
For use with: 2600-PCT-x, 4200-PCT-x, 8010

LIV curves
 

CA-563C: BNC to banana jumper (240 mm).
For use with: 2600-PCT-x, 4200-PCT-x, 8010

LIV curves
 

CA-568-xA: Protective earth safety ground cable with eye lugs (x = 12, 18, or 120 inches).
For use with: 2657A, 2657-LIM-3, 2657-PIM-200, 8010

LIV curves
 

2290-10-SHV: 3 m (10 ft) of RG-213/U coaxial cable terminated with a SHV male connector on both ends. Maximum operating voltage is 10,000 Vrms.
For use with: 2290-10, 2290-10-SHVBH

LIV curves
 

2290-10-SHVUC: 3 m (10 ft) of RG-213/U coaxial cable terminated with a SHV male connector on one end and unterminated cable on the other end. Maximum operating voltage is 10,000 Vrms.
For use with: 2290-10

LIV curves
 

4200-MTRX-*: Ultra low noise SMU triax cable is terminated with a miniature male triax connector on one end and a standard 3-slot male triax connector on the other end. This cable connects a 4200-SMU or 4210-SMU source measurement unit installed in a 4200ASCS to a test fixture. (4200-MTRX-* cables are intended only for connection to an SMU that does not have a 4200-PA PreAmp installed.)

4200-MTRX-1: 1 m (3.2 ft)

4200-MTRX-2: 2 m (6.5 ft) (two included with each 4200A-SCS SMU not configured with a 4200-PA Remote PreAmp)

4200-MTRX-3: 3 m (9.8 ft)
For use with: 4200A-SCS

LIV curves
 

4200-RPC-2: Remote PreAmp cable terminated at each end with a high density DB15 connector. This cable connects a 4200-SMU or 4210-SMU source measurement unit installed in a 4200A-SCS to a remotely mounted 4200-PA PreAmp. 2 m (6.5 ft) (one included with each 4200-PA).
For use with: 4200-PA

LIV curves
 

7078-TRX-* 3-slot Triax Cables: Low noise triax cables terminated at both ends in 3-slot male triax connectors.

7078-TRX-1 0.3 m (1 ft)

7078-TRX-3 0.9 m (3 ft)

7078-TRX-5 1.5 m (5 ft)

7078-TRX-10 3.0 m (10 ft)

7078-TRX-12 3.5 m (12 ft)

7078-TRX-20 6.0 m (20 ft)
For use with: 2635B, 2636B, 6220, 6221, 6482, 6487, 6514, 6517A, 6517B, 7072, 7174A

7705-MTC-2: 2 m (6.6 ft) 50-conductor male to female D-sub cable assembly.
For use with: 7703, 7705, 7707, 7709, 7701

LIV curves
 

CA-18-1: 1.2 m (4 ft) shielded cable ter - minated with a dual banana plug on each end. For use with binding post inputs or dual banana jacks.
For use with: Binding post inputs

LIV curves
 

CA-451A: 10.8 cm (4.25 in) RG188 coax cable terminated with an SMA male plug on each, 50 Ω impedance.
For use with: 4200A-SCS

LIV curves
 

CA-452A: 20.4 cm (8 in) RG188 coax cable terminated with an SMA male plug on each end, 50 Ω impedance.
For use with: 4200A-SCS

LIV curves
 

CA-557-*: 8-pin male to 8-pin male cable assembly with straight through pin configuration.

CA-557-1: 1 m (3.3 ft)

CA-557-2: 2 m (6.6 ft)

CA-557-3: 3 m (10 ft)
For use with: 2601B, 2602B, 2611B, 2612B, 2651A SourceMeter® SMU Instruments, 2600-PCT-x, 4200-PCT-x, 8010

LIV curves
 

HV-CA-554-x: High voltage triax to triax cable (3 kV rated) (x = 1, 2, or 3 m).
For use with: 2657A, 2657-LIM-3, 2657-PIM-200, 8010

LIV curves
 

HV-CA-571-3: High voltage triax to unterminated cable.
For use with: 2657A, 2600-PCT-x, 4200-PCT-x

LIV curves
 

SHV-CA-553-x: High voltage triax to SHV cable (x = 1 or 3 m) (3 kV rated).
For use with: 2657A

LIV curves
 

2290-INT-CABLE: Safety interlock cable, 3.05 m (10 ft). 3-conductor cable with 3-pin connector on one end and unterminated wires on the other end.
For use with: 2290-5, 2290-10

LIV curves
 

2450-TRX-BAN: For adapting the 2450’s rear panel triaxial connectors to banana jack inputs. Length: 0.3 m (1 ft).
For use with: 2450

LIV curves
 

2600-ALG-2: 2 m (6.6 ft) cable terminated with a 3-slot male triax connector on one end and 3 alligator clips on the other.
For use with: 2635B, 2636B, 4200-PA

LIV curves
 

4200-TRX-*: Ultra low noise PreAmp triax cable terminated with a standard 3-slot male triax connector on each end. This cable connects a 4200-PA PreAmp option installed in the 4200A-SCS to the test fixture.

4200-TRX-0.3: 0.3 m (1 ft) (recommended for remote location of the 4200-PA)

4200-TRX-1: 1 m (3.2 ft)

4200-TRX-2: 2 m (6.5 ft) (two included with each 4200-PA)

4200-TRX-3: 3 m (9.8 ft)
For use with: 4200-PA

LIV curves
 

4801 Input Cable: Low noise coax cable, 1.2 m (48 in) in length, with male BNC connectors on each end.
For use with: 6482, 6485

LIV curves
 

CA-19-2: 1.5 m (5 ft) RG58 cable terminated with a BNC male plug on each end.
For use with: 4200A-SCS

LIV curves
 

CA-126-1A Digital I/O Cable: 1.5 m (5 ft) of cable, from DB25 male to DB25 female.
For use with: Series 2600B, Series 3700A

LIV curves
 

CA-404B: 2 m (6.5 ft) RG188 coax cable terminated with an SMA male plug on each end, 50 Ω impedance.
For use with: 4200A-SCS, System 46, System 46T

LIV curves
 

CA-405B: 15 cm (6 in) RG188 coax cable terminated with an SMA male plug on each end, 50 Ω impedance.
For use with: 4200A-SCS

LIV curves
 

CA-558-2: 25-pin D-sub to 3-pin interlock cable assembly.
For use with: Series 2600B, 2600-PCT-x, 2651A, 2657A, 4200A-SCS, 4200-PCT-x, 8010

LIV curves
 

CA-559-0A and CA-559-2A: Banana to banana jumper (102 mm).
For use with: 2600-PCT-x, 4200-PCT-x, 8010

CA-560-0A and CA-560-2A: Banana to banana jumper (203 mm).
For use with: 2600-PCT-x, 4200-PCT-x, 8010

CA-561-0A and CA-561-2A: Banana to banana jumper (305 mm).
For use with: 2600-PCT-x, 4200-PCT-x, 8010

LIV curves
 

SC-9: Low noise coax cable without connectors (sold by the foot).

LIV curves
 

SC-22: Low noise triax cable without connectors (sold by the inch).
For use with: CS-631

LIV curves
 

SC-182: Low inductance (42 nH/ft) coaxial cable for minimizing test lead impedance in circuits using fast transient response power supplies. The cable is sold by the foot and comes without connectors.
For use with: 2302, 2303, 2303-PJ, 2304A, 2306, 2306-PJ, 2306-VS

Find more valuable resources at TEK.COM


Copyright © Tektronix. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies.

100722 1KW-73964-1