Frequently Asked Questions
FAQ | |
---|---|
Can the AWG7000 be used to output a video test signal for SDI testing? No. The AWG7000 does not have the proper memory structure to generate SDI test signals. We recommend using a video test generator such as our TG700 with the appropriate module (DVG7, HDVG7 or SDI7). This FAQ Applies to: |
64526 |
: The RTSA spectrogram displays the time values and these values can be changed. Can the MDO do this? Not at this time. Displaying the time values has been added to our list of recommended product enhancements. This FAQ Applies to: |
64521 |
“Low disk space” or “page-file” or “Virtual Memory" errors/warnings after performing a OS Restore or backup on oscilloscopes running Win7? If, after performing an OS restore or creating a backup image, the oscillscope reports “low disk space”, “page-file”, “Virtual Memory" errors/warnings, TekScope not starting up, or experiencing odd Windows behavior, try the following proceedure to recover … This FAQ Applies to: |
64516 |
Where can I get Technical Support for these products: PB200+ GB700+ GB1400+ SJ300E+ ST2400+ ST2400A+ CSA907+ CSA907A+ ST100 series?
The business unit that manufactured, serviced, and provided technical support for these products was sold in October, 2002. Please direct all inquiries regarding this products to: Veracity Technology Services, Inc 124 Heritage Way #9 Portsmouth, NH … This FAQ Applies to: |
64511 |
What probes are supported on the RF input of the MDO3000 and MDO4000 series?
The RF input on the MDO3000 and MDO4000 series has an N connector, so the RF input can support cables, antennas, and other adapters typically used with a spectrum analyzer. The RF input is 50 ohms and it is AC coupled. Below is a listing of some … This FAQ Applies to: |
64506 |
What is included in the Tektronix Near Field Probe kit (Tek p/n 119-4146-00) and what are they used for?
The Tektronix 119-4146-00 Near Field Probe Set is intended to serve as a versatile aid for diagnostic testing of radiated emissions over a broad range of frequencies from below 100 kHz to above 1GHz. The probe set consist of three (3) magnetic field … This FAQ Applies to: |
64501 |
What is the bandwidth of the 80A03? The bandwidth of the 80A03 is depended on the serial number. Bandwidth is DC to 12.5GHz for serial numbers up to B020423 and 18GHz typical for serial numbers B020424 and higher. These are nominal specification. The 18GHz units should have decent … This FAQ Applies to: |
64496 |
MDO4000 Series: Is an RF acquisition from an MDO4000 Series compatible with RSAVu? Yes. Baseband I&Q data from the MDO4000 Series RF input can be saved to a .TIQ file (note flatness correction is not applied). TIQ files can then be imported into RSAVu software for further analysis (such as pulse analysis, demodulation analysis). This FAQ Applies to: |
64486 |
MDO4000 Series: In spectrogram mode+ are the slices time continuous or are there time gaps between slices? Each slice is a new acquisition, thus there will be a time gap between each slice (acquisition).The MDO4000 Series spectrogram shows what is happening in the spectrum over time and allows you view how the spectrum changed over time by looking “back in … This FAQ Applies to: |
64481 |
Is the Windows 7 driver for the RS232 to USB cable adapter (p/n:174-5813-00) available? The driver for the adapter 174-5813-00 for Windows 7 support is available from its chip vendor at here. This FAQ Applies to: |
64476 |