Is it possible to perform a continuous Analog Input operation, while also performing an Analog Output (single value) function with the KUSB-3102, KUSB-3108 or KUSB-3116?

問題:

Is it possible to perform a continuous Analog Input operation, while also performing an Analog Output (single value) function with the KUSB-3102, KUSB-3108 or KUSB-3116?

答案:

Product(s):

USB Modules: KUSB-3100 Series: KUSB-3102, KUSB-3108, KUSB-3116,


Question:Is it possible to perform a continuous Analog Input operation, while also performing an Analog Output (single value) function with the KUSB-3102, KUSB-3108 and KUSB-3116?


Answer:This is not possible with the KUSB-3102 and KUSB-3108.It is only possible to perform a Single Value Analog Input and Single Value Analog Output.However, it is possible with the KUSB-3116 to perform simultaneous subsystem operations. 