問題:
How do I configure the DIP switches on my VITS100?
答案:
Information regarding the DIP switch configuration can be found on pages 2-5 through 2-7 of the VITS100 user manual. You can download this manual from the following link:
VITS signal selection for the individual vertical interval lines is made with four DIP switches (S1-S4) mounted on the VITS inserter circuit board. Remove the small panel from the top cover of the VITS inserter, as shown in Figure 2-4, to gain access to these switches.
Switches S1 and S2 make the selections for fields 1 and 3, and switches S3 and
S4 make the selections for fields 2 and 4. Each DIP switch selects the test signals for two of the vertical interval lines, as shown in Figure 2-5.
Table 2-2: DIP Switch Settings
VITS inserter Action DIP Segment Settings*
1 (5) 2 (6) 3 (7) 4 (8)
Insert Test Signal:
0% Black (two settings) = 0 1 1 0 or 1 0 0 1
7.5% Black = 1 1 1 0
50% Gray = 1 1 0 1
FCC Color Bars = 0 0 0 0
FCC Composite = 1 0 0 0
Multiburst = 0 1 0 1
Multipulse = 0 1 0 0
NTC 7 Composite = 1 0 1 0
NTC 7 Combination = 0 0 0 1
Red Field = 1 1 0 0
SIN X/X = 0 0 1 0
VIRS = 1 0 1 1
Pass Program Video = 1 1 1 1
Auto VIRS = 0 0 1 1
Insert Source ID = 0 1 1 1
* 1 signifies an OPEN switch; 0 signifies a closed switch