GPIB commands documentation seems to be missing a way to read the noise cursor readings in mv or dB. Is there such a command?

問題:

GPIB commands documentation seems to be missing a way to read the noise cursor readings in mv or dB. Is there such a command?

答案:

The commands are in there, but not documented in the manual:

vari:val? "NoiseAmpCursordBCh1" returns "NoiseAmpCursordBCh1 -151.09"

vari:val? "NoiseAmpCursormVCh1" returns "NoiseAmpCursormVCh1 0.0"

Change the 1 to either 2 or 3 to get the other values.

This information has been added to the latest manual, part number 071-2104-00