Frage:
How do you get the AVG7 module into 480P Y+Pb+Pr mode?
Antwort:
480P is also known as 525P. If 525p YPbPr is not already loaded onto the TG700:
Download the TG700) signal library 1 and Library 3 files, and the TG700 tools from our website to your PC. Links are as follows:
TG700 Library 1
TG700 Library 3
TG700 Tools
Unzip the files.
Once this is done, connect to the TG700 through the network connection using the TG7COMM program, found in the tools. See TG700 manual page 3-15 for details if needed. Once communication is established, Open the AVG7/signal folder.
Select FILE PC TO TG. Select the SIGNAL LIBRARY\AVG7\UNCHECKED\525p_ypb.dnl file and click DOWNLOAD.
When done reboot the TG700 by pressing MODULE, FORMAT, and FRONT PANEL ENABLE buttons at the same time