High-Speed Inter Connect (HSIC) Solution Datasheet

HSIC Essentials

Features & Benefits

Electrical Validation
  • Automated Setup Library for electrical measurements saves setup time and test time.
  • 100% Host and Device tests coverage provides confidence in design testing.
  • Seamless Debug Analysis enables investigating failures for root-cause analysis.
  • Flexible Setup for Characterization and Customization enables testing needs beyond compliance.
Protocol Decode
  • Protocol decode Saves test time and resource costs.
  • Designed for use with the MSO/DPO5000, DPO7000C, DPO/DSA/MSO70000C, and DPO/DSA70000D Series Oscilloscopes.
  • Search for Sync, Reset, Suspend, Connect, Resume, Error, Addr,CRC, and Data fields.
  • Event table with time-stamp and export to .csv file for further analysis.

Applications

  • HSIC Host and Device silicon characterization, debug and validation.
  • HSIC compliance testing to the specification.
  • Protocol verification.
  • System integration and validation of HSIC bus in mobile phones, tablet PCs and portable computer designs.
  • Manufacturing test.

 

Tektronix provides comprehensive, integrated tool sets to serve the needs of engineers designing HSIC based embedded systems as well as those validating the physical-layer compliance of HSIC serial devices to the HSIC standard.

The Tektronix MSO/DPO5000, DPO7000C, DPO/DSA/MSO70000C, and DPO/DSA70000D Series oscilloscopes enabled with option HSIC provide automated setup for complete electrical as well as protocol validation of HSIC Device and Host designs.

Electrical Validation

DPOJET software with HSIC Essentials Setup Library provides a full set of measurements required for HSIC Device and HOST testing. The HSIC Essentials enable Debug Analysis and Characterization to the HSIC specification.

Automated Testing – Save Time and Resources

There is no longer a need to be an expert on HSIC testing procedures. Remembering the exact steps to take each measurement is time consuming and often requires going back to the HSIC specifications. HSIC Essentials takes the guesswork out of conducting Device and Host electrical testing. Even if you remember how to use the test equipment, it is common for even the HSIC experienced operators to forget steps in the procedure or to set up the correct parameters, such as applying the correct record length and sampling rates.

Automated DPOJET Setup Library for HSIC provides standard specific details and pre-defined scope settings for each measurement, so the user does not need to be an expert. HSIC Essentials minimizes the setup initialization problems, reduces the complexity of executing HSIC tests and enables you to test designs faster.

HSICEssentialsHighSpeedInterConnectHSICSolution-2-N

HSIC Standard option in DPOJET standard menu

100% Test Coverage

HSIC Essentials provide complete set of measurements to be performed across near-end and far end test points, for both device and host validation. Measurements include Signal Quality tests such as Eye mask hits, Strobe Frequency, Packet parameter tests, and Bus timing tests.

HSICEssentialsHighSpeedInterConnectHSICSolution-3-N

Location of HSIC Test Points

HSICEssentialsHighSpeedInterConnectHSICSolution-4-N

DPOJET automated Opt.HSIC provides 100% test coverage for both Device and Host

Seamless Debug and Analysis with HSIC Essentials

HSIC Essentials helps perform step-by-step debugging on failures. HSIC Essentials helps debug faster and discover sources of jitter and signal integrity issues quickly.

Flexible and Customizable for Characterization

The HSIC Essentials Setup Library is highly flexible, and fully-customizable. It allows modifying the measurement settings, scope configurations, limits and other parameters editing and then save the customized setup. For example, when testing a HSIC interconnect bus on a mobilephone design in a temperature chamber setup or when using remote XL cables in the setup, a user can define additional filter files and custom-limits to suit the setup conditions.

Plots and Results

The DPOJET Plot feature for HSIC Essentials helps characterize HSIC devices with detailed visual representations. The Result section helps design engineers to look at the test results quickly and clearly. The Report section includes details of each test including Limits, Measured Value, Pass/Fail Results, etc.

HSICEssentialsHighSpeedInterConnectHSICSolution-5-N

HSIC Device Eye Diagram Test

HSICEssentialsHighSpeedInterConnectHSICSolution-6-N

HSIC Device Signal Quality Measurement Result

Detailed Reports

The HSIC Essentials application generates thorough HTML/.MHT reports that capture the performance, status, and test results of your device. It also captures eye diagram, oscilloscope waveform screen captures, along with test waveforms optionally. Report generation tool also provide features such as Report Appending, Auto Incrementing Report Naming, Inserting User Comments, Listing Complete Configuration Details, etc. Reports appending feature enables adding results from each of the near-end/far-end test points for both Device and Host designs under test, and create a single-printable-report for sharing the results.

HSICEssentialsHighSpeedInterConnectHSICSolution-7-N

Report for HSIC with Pass/Fail summary

HSIC Protocol Decoding

HSIC Essentials will provide protocol decode that can disassemble the HSIC traffic, and decodes according to the protocol, and displayed the decoded data on waveform and event-table, along with red flags on CRC/ECC errors in the decoded data. You can view protocol decode along with time stamps on the decoded data in event-tables.

HSICEssentialsHighSpeedInterConnectHSICSolution-8-N

HSIC Decoder bus settings

HSICEssentialsHighSpeedInterConnectHSICSolution-9-N

HSIC Decoder along with signal waveform

HSICEssentialsHighSpeedInterConnectHSICSolution-10-N

HSIC protocol decode Event Table

HSIC packet content search is very useful for isolating the event of interest, but once you’ve captured it and need to analyze the surrounding data, what do you do? In the past, users had to manually scroll through the waveform counting and converting bits and looking for what caused the event. With the HSIC protocol decoder application, you can enable the oscilloscope to automatically search through the acquired data for user-defined criteria including serial packet content. Each occurrence is highlighted by a search mark. Rapid navigation between marks is as simple as pressing the Previous (←) and Next (→) buttons on the front panel.

HSICEssentialsHighSpeedInterConnectHSICSolution-11-N

HSIC Decoder Search fields

HSICEssentialsHighSpeedInterConnectHSICSolution-12-N

Results of HSIC Decoder Search
 

Characteristics

Instrument Compatibility

Oscilloscope

Description

MSO5204

DPO5204

DPO7254C

DPO7354C

All DPO/DSA/MSO70000C/D models

HSIC Essentials - Electrical Validation and Protocol Decode Solution

Electrical Testing Options

Characteristic

Description

HSIC Tests

Host and Devices

Signal Quality Tests

Eye Diagram Test, High-Low Voltage, Skew rate, Strobe Frequency, Rx Setup and Hold

Packet Parameter Tests

Inter Packet Gap, Sync Field, EOP, Second Inter Packet Gap

Bus Timing Tests

Suspend, Resume, Reset from Suspend, Reset from high speed

Test Point Selection

Near End and Far End

Report Generation Format

DPOJET reports

Bus Decoding Options

Characteristic

Description

Sources

Analog channels 1-4

Digital channels D0-D15 (MSO5000 and MSO70000C Series only)

Input Thresholds

Mid-levels for Data and Strobe

Search

Sync, Reset, Suspend, Connect, Resume, Error, Addr, CRC5, CRC16, Data

Address/Data Formats

Hex, Binary, Decimal

Display Modes

   

   Bus

Bus only

   Bus and waveforms

Simultaneous display of bus and waveforms

   Event table

Decoded packet data in a tabular view

Export

Export data to .csv format

Ordering Information

Opt.HSIC HSIC Essentials - Electrical Validation and Protocol Decode

Model

New Instrument Orders

Product Upgrades

Floating Licenses

MSO/DPO5000/GSA Series (2 GHz and above)

Opt. HSIC

DPO-UP Opt. HSIC

DPOFL-HSIC

DPO7000C/GSA Series (2.5 GHz and above)

Opt. HSIC

DPO-UP Opt. HSIC

DPOFL-HSIC

DPO/DSA/MSO70000C/D/GSA Series

Opt. HSIC

DPO-UP Opt. HSIC

DPOFL-HSIC

Recommended Accessories

Two sets of TAP1500 or P6245 Probes along with PPM100 Probe Holders are required for HSIC electrical testing as well as protocol decoding.

Please refer to www.tek.com/probes for further information on the recommended models of probes and any necessary probe adapters.

Additional Information

Tektronix offers a range of solutions for USB testing, including HSIC, USB 2.0 and USB 3.0. To see a comprehensive listing, and download the latest resources, visit www.tek.com/USB.

USB solution updates and up-to-date instrument software upgrades are available at www.tek.com/downloads.