ダウンロード

マニュアル、データシート、ソフトウェアなどのダウンロード:

ダウンロード・タイプ
型名またはキーワード

フィードバック

TLA5000 Series Upgrade Guide

TLA5KUP Mainframe Field Upgrade Kits

このデータ・シートの製品は、テクトロニクスでは販売終了となっています。
Tektronix Encoreプレミアム再生品を見るbr/>​
上記製品のサポート保証のステータスをチェックする

TLA5KUP Mainframe Field Upgrade Kits

If you own a TLA520x logic analyzer, you can upgrade the following capabilities using the TLA5UP Mainframe Field Upgrade Kit:

  • Upgrade to the latest TLA applications software and MS Windows operating system
  • Upgrade to add external oscilloscope capability by adding the iView external oscilloscope interface

TLA5KUP Mainframe Field Upgrade Kits

The TLA5UP kits are customer-installable field upgrade kits for the TLA5000 Series which provide valuable enhancements to your TLA logic analyzer:

TLA5000 Products Eligible for TLA5KUP Upgrades

Configuration

Operating System

TLA Application Software

TLA520x

Microsoft Windows 2000 Professional

Version 4.4

Version 4.3

 

New Capability Desired

Current Mainframe Configuration

Current Operating System Version

Current TLA Application Software Version

Please Order

Add New SW Features

 

Add new functionality to existing TLA520x logic analyzer by upgrading to latest TLA Applications Software.

 

Requires Windows 2000 Professional Operating System.

TLA520x

Windows 2000 Professional

Version 4.4

— —

Version 4.3

TLA5KUP Option 35 (w/ HD Image CD) [recommended]

 

-OR-

 

TLA5KUP Option 36 (w/o HD Image CD)

 

New Capability Desired

Current Mainframe Configuration

Current Operating System Version

Current TLA Application Software Version

Please Order

Add New iView External Oscilloscope Capability

 

Add new iView capability to view data from your TDS oscilloscope correlated directly on your TLA5000 logic analyzer display

 

(For a list of currently supported TDS oscilloscopes, please visit our website at www.tektronix.com/la).

 

Requires latest TLA Application Software and Windows 2000 Professional Operating System.

 

TLA5000 mainframe memory requirements: 512MB required.

TLA520x

Windows 2000 Professional

Version 4.4

TLA5KUP Option 15

Version 4.3

TLA5KUP Option 15

TLA5KUP Option 35 (w/ HD Image CD) [recommended]

 

-OR-

 

TLA5KUP Option 36 (w/o HD Image CD)

 

New Capability Desired

Current Mainframe Configuration

Current Operating System Version

Current TLA Application Software Version

Please Order

Upgrade Logic Analyzer Record Length

 

Enhance your current TLA5000 logic analyzer by increasing Record Length.

 

Run the PowerFlex Utility SW to inform you what PowerFlex upgrades are available. Complete instructions on how to obtain a PowerFlex option key are provided.

TLA520x

Windows 2000 Professional

Version 4.4

Version 4.3

Run PowerFlex Utility SW located on TLA5000 and then purchase appropriate TLA5Fxxx PowerFlex Kit.

 

New Capability Desired

Current Mainframe Configuration

Current Operating System Version

Current TLA Application Software Version

Please Order

Add Cart

TLA520x

— —

— —

Choice of either K4000 or LACART

Add Rackmount Kit

TLA520x

— —

— —

016-1790-04 (same as used for TDS5000)

Add Wheeled Transport Case

TLA520x

— —

— —

016-1522-00

Notes

(1) All TLA Application Software has been tested, can be installed and will be supported by Tektronix only on the Tektronix-supplied version of Windows 2000 Professional.

(2) The TLA5KUP is designed for “one TLA5KUP per TLA5000 mainframe”. If upgrading multiple TLA5000s, you must order one TLA5KUP with the appropriate options for each TLA5000 mainframe.

Current Version of TLA Application Software Downloadable From Tektronix Web Site

TLA application software is available for download directly from Tektronix and contains:

  • Self-extracting image of the TLA application software
  • Installation instructions
  • Release notes

Note: All TLA application software has been tested, can be installed and will be supported by Tektronix only on Tektronix-supplied Windows 2000 Professional.

The downloadable version of TLA Application Software does not contain any non-Tektronix licensed software (including CheckIt Utilities, SnagIt, RecordNow Max, and National Instruments GPIB-USB Software). You can receive a copy of the full version by ordering one from the Tektronix website or by ordering a TLA5KUP with the appropriate option at no cost.

TLA Application Software Releases

Tektronix continues to innovate and enhance the TLA applications software for the TLA family of logic analyzers. The TLA5000, TLA600, and TLA700 logic analyzers share the same TLA applications software. Setups and data can be quickly and easily shared between the Series. Tektronix has demonstrated its commitment to continually improving the TLA family with several software upgrades since the original Version 1.0 release. The following table shows the compatibility of software used in the TLA by version numbers. Each software version is compatible with the other software versions in the same column. Each column indicates the software or firmware history of the TLA products as shipped from the factory.

Release

4.4

4.3SP1

4.3

4.2SP1

4.2

3.2

TLA Application SW

4.4

4.3SP1

4.3

4.2SP1

4.2

3.2

   TLA Application

4.4.075

4.3.261

4.3.225

4.2.112

4.2.098

3.2.038

   TLA7NAx FW

4.4.005

N/A

N/A

N/A

N/A

N/A

   TLA7Axx FW

4.4.005

4.3.037

4.3.034

4.2.084

4.2.081

NA

   TLA7N/P/Qx FW

4.3.14

4.3.14

4.3.14

4.1.4

4.1.4

3.2.0

   TLA7L/Mx FW

3.2.1

3.2.1

3.2.1

3.2.1

3.2.1

3.2.1

   TLA7D/Ex

3.1.1

3.1.1

3.1.1

3.1.1

3.1.1

3.1.1

   TLA6xx FW

4.3.15

4.3.15

4.3.15

4.2.0

4.2.0

3.2.16

   TLA520x FW

4.4.001

4.3.032

4.3.28

NA

NA

NA

   MF Diagnostics

4.4.075

4.3.261

4.3.225

4.2.098

4.2.098

3.2.038

   Firmware Loader

4.4.075

4.3.261

4.3.225

4.2.098

4.2.098

3.2.038

   TLAScript

4.4.075

4.3.261

4.3.225

4.2.112

4.2.098

3.2.038

   TLASym

4.4.075

4.3.261

4.3.225

4.2.112

4.2.098

3.2.038

   AutoDeskew

4.4.76.0

4.3.140.0

1.0.48.0

N/A

N/A

N/A

   ChannelImportExp

4.3.2.0

4.3.2.0

1.0.4.0

N/A

N/A

N/A

   Graph Window

4.4.76.0

4.3.141.0

1.0.50.0

N/A

N/A

N/A

   iVerify

4.4.76.0

4.3.140.0

1.0.48.0

N/A

N/A

N/A

   Protocol Designer

4.4.76.0

4.3.129.3

1.0.34.0

N/A

N/A

N/A

   Protocol Window

4.4.76.0

4.3.143.0

1.0.50.0

N/A

N/A

N/A

TLAVu

4.4.075

4.3.261

4.3.225

4.2.112

4.2.098

3.2

TPI Client SW

4.4.075

4.3.261

4.3.225

4.2.098

4.2.098

3.2

PatGen App SW

1.6.011

1.5.003

1.5.003

1.4.002

1.3.032

1.0.000

   PatGen FW

2.01

2.01

2.01

2.01

2.01

2.01

PatGenVu

1.6.011

1.5.003

1.5.003

1.4.002

1.3.032

1.0.000

PPI Client SW

1.6.011

1.5.003

1.5.003

1.4

1.3.032

1.0

Windows 2000

5.00.2195

SP4

5.00.2195

SP4

5.00.2195

SP4

5.00.2195

SP4

5.00.2195

SP4

NA

Windows 98

NA

NA

NA

NA

NA

4.10.2222

MS .NET Framework

1.1.4322

1.0.3705

1.0.3705

NA

NA

NA

QA+Win32

NA

NA

NA

NA

NA

2.0

SnagIt

7.0.0

6.1.1

6.1.1

5.2

5.2

NA

CheckIt Utilities

7.0

7.0

7.0

6.5.5

6.5.5

NA

NI-488.2

2.1

2.1

2.0

2.0

1.01

NA

NI-MAX

2.2.0

2.2.0

2.2.0

2.2.0

2.0.3.17

NA

RecordNow MAX

4.50

4.50

4.50

NA

NA

NA

Click’N Burn Pro

NA

NA

NA

2.01

2.01

NA

Adobe Reader

6.0

6.0

6.0

5.0

5.0

NA

TLA715/721 BIOS

1.00.02

1.00.02

1.00.02

1.00.02

1.00.02

NA

TLA714/720 BIOS

2.03.11

2.03.11

2.03.11

2.03.11

2.03.11

2.03.11

TLA704/711 BIOS

NA

NA

NA

NA

NA

1.00.14

TLA600 BIOS

P9-0009

P9-0009

P9-0009

P9-0009

P9-0009

0005.P05

TLA5200 BIOS

0040.P16

0040.P16

0040.P16

NA

NA

NA

Note: All TLA application software has been tested, can be installed, and will be supported by Tektronix only on Tektronix-supplied Windows 2000 Professional.

We are consistently adding to the list of supported oscilloscopes that combine with the TLA Series logic analyzers to provide iView (Integrated View) capability. The following table gives a history of oscilloscopes and TLA Application Softwareversions along with interim iView updates. This includes which version of TLA software supports which oscilloscopes.

   

TLA SW V4.4 Release

TLA SW V4.3 SP1

TLA SW V4.3 Release

iView V4.2.1 Upgrade

TLA SW V4.2 SP1

TLA SW V4.2 Release

iView V4.1.4 Upgrade

iView V4.1.3 Upgrade

TLA SW V4.1 SP2

iView V4.1.1 Upgrade

TLA SW V4.1 Release

   

TLA App Version

4.4

4.3 SP1

4.3

4.2 SP1

4.2 SP1

4.2

4.1 SP2

4.1 SP2

4.1 SP2

4.1

4.1

iView Version

4.3.5

4.3.2

4.3.0

4.2.1

4.2.0

4.2.0

4.1.4

4.1.3

4.1.2

4.1.1

4.1.0

Date (approx)

21-Jun-04

22-Dec-03

8-Aug-03

3-Apr-03

9-Aug-02

6-Apr-02

11-Jan-02

13-Nov-01

20-Sep-01

1-Aug-01

4-Jun-01

# of scopes

55

53

42

40

32

32

32

27

18

17

12

   

TDS724D

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

   

   

TDS754C

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

   

   

TDS754D

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

   

   

TDS784C

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

   

   

TDS784D

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

   

   

TDS794D

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

   

   

   

TDS654C

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

   

   

   

TDS684C

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

TDS694C

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

TDS1002

Yes

Yes

Yes

Yes

   

   

   

   

   

   

   

TDS1012

Yes

Yes

Yes

Yes

   

   

   

   

   

   

   

TDS2002

Yes

Yes

Yes

Yes

   

   

   

   

   

   

   

TDS2012

Yes

Yes

Yes

Yes

   

   

   

   

   

   

   

TDS2014

Yes

Yes

Yes

Yes

   

   

   

   

   

   

   

TDS2022

Yes

Yes

Yes

Yes

   

   

   

   

   

   

   

TDS2024

Yes

Yes

Yes

Yes

   

   

   

   

   

   

   

   

TDS3012

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

TDS3014

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

TDS3032

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

TDS3034

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

TDS3052

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

TDS3054

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

TDS3012B

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

TDS3014B

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

TDS3032B

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

TDS3034B

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

TDS3052B

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

TDS3054B

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

   

TDS5032

Yes

Yes

Yes

   

   

   

   

   

   

   

   

TDS5034

Yes+iV

Yes+iV

Yes+iV

   

   

   

   

   

   

   

   

TDS5052

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

   

   

TDS5054

Yes+iV

Yes+iV

Yes+iV

Yes

Yes

Yes

Yes

Yes

   

   

   

TDS5104

Yes+iV

Yes+iV

Yes+iV

Yes

Yes

Yes

Yes

Yes

   

   

   

   

TDS5032B

Yes

Yes

   

   

   

   

   

   

   

   

   

TDS5034B

Yes+iV

Yes+iV

   

   

   

   

   

   

   

   

   

TDS5052B

Yes

Yes

   

   

   

   

   

   

   

   

   

TDS5054B

Yes+iV

Yes+iV

   

   

   

   

   

   

   

   

   

TDS5054BE

Yes+iV

Yes+iV

   

   

   

   

   

   

   

   

   

TDS5104B

Yes+iV

Yes+iV

   

   

   

   

   

   

   

   

   

   

TDS6404

Yes+iV

Yes+iV

Yes+iV

Yes

   

   

   

   

   

   

   

TDS6604

Yes+iV

Yes+iV

Yes+iV

Yes

Yes

Yes

Yes

   

   

   

   

   

TDS6604B

Yes+iV

   

   

   

   

   

   

   

   

   

   

TDS6804B

Yes+iV

   

   

   

   

   

   

   

   

   

   

   

TDS7054

Yes+iV

Yes+iV

Yes+iV

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

TDS7104

Yes+iV

Yes+iV

Yes+iV

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

TDS7154

Yes+iV

Yes+iV

Yes+iV

Yes

Yes

Yes

Yes

   

   

   

   

TDS7254

Yes+iV

Yes+iV

Yes+iV

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

TDS7404

Yes+iV

Yes+iV

Yes+iV

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

   

TDS7154B

Yes+iV

Yes+iV

   

   

   

   

   

   

   

   

   

TDS7254B

Yes+iV

Yes+iV

   

   

   

   

   

   

   

   

   

TDS7404B

Yes+iV

Yes+iV

   

   

   

   

   

   

   

   

   

TDS7704B

Yes+iV

Yes+iV

   

   

   

   

   

   

   

   

   

   

CSA7154

Yes+iV

Yes+iV

Yes+iV

Yes

Yes

Yes

Yes

   

   

   

   

CSA7404

Yes+iV

Yes+iV

Yes+iV

Yes

Yes

Yes

Yes

   

   

   

   

   

CSA7404B

Yes+iV

Yes+iV

   

   

   

   

   

   

   

   

   

Notes

1. "Yes" means supported by iView.

2. "Yes+iV" means supported by iView and iVerify.

Besides the latest features in Version 4.4 of the TLA application software, the following section shows the history of features added to the TLA application software.

Key NEW Features in TLA Application Software Releases for TLA5000

Version 4.4 -

  • TLA7NAx Logic Analyzer Modules for the TLA700 Series - including 8 GHz MagniVu timing, 2 GHz deep timing, 235 to 450 MHz state clock rates, 512 Kb to 32 Mb record length.

Version 4.3 -

  • TLA5000 Series Logic Analyzers with 500 ps (2 GHz) deep memory timing with up to 32 Mb memory depth, with 125 ps MagniVu acquisition, simultaneous with 235 MHz state acquisition.
  • TLACAL1 Calibration Fixture.
  • iLink™ Toolset.
    • iConnect™ - simultaneous analog and digital acquisition through a single logic analyzer probe.
    • iView™ - displays automatically time-correlated analog and digital data on a single logic analyzer display.
    • iVerify™ - enables multi-channel analysis and validation using high-resolution oscilloscope-generated eye diagrams.
  • Filter/Color.
  • Enhanced Search.
  • Graph Window.
  • AutoDeskew.
  • iVerify™.
  • TPI.NET.
  • Protocol Display Window and Protocol Designer.
  • Multi-language Windows 2000 Professional.
  • Import/Export Channel and Group Definitions.
  • EasySetup Wizard.
  • Zoom Immediate.
  • DSO Channels have TDS Colors.
  • Microsoft Windows Colors.
  • LA Setup Toolbar.
  • Tools Toolbar and Menu Item.
  • Highlight Channel Names.
  • Rename Channel/Group from Data Window.
  • User-defined Default Waveform Height.
  • Support for LA Status Channels.
  • Per Channel Clock and Setup/Hold Violation Definition.
  • Merge Modules with Different State Speeds.
Installation Notes

When you purchase a new TLA Logic Analyzer, the basic TLA Version 4.4 application software is installed at the factory. Some software packages must be installed separately, such as microprocessor and bus support packages. For information about these packages, refer to their associated documentation or contact your local Tektronix account manager.

Do not install the TPI Client Software on the logic analyzer. The TPI Client Software is for installation on a separate, remote PC that will control the logic analyzer using the TLA Programmatic Interface (TPI). See the TPI online help on your TLA logic analyzer for more information.

File Compatibility

Saved system files which include setup and data information are "forward-compatible" with each release of TLA applications software, i.e., a V1.1 saved system file will properly load on TLA logic analyzers with Version 4.4 software. However, saved system files are not "backwards-compatible," that is, a Version 4.4 saved system file will not load on a TLA logic analyzer with Version 3.2 or earlier software.

Module/Instrument Firmware Compatibility

After upgrading the TLA applications software in your TLA mainframe, you will often be required to upgrade the firmware in your logic analyzer, pattern generator, and digitizing oscilloscope modules. However, while you are not required to re-run any performance verification/adjustment procedures, you are encouraged to run both self-calibration and extended diagnostics on all mainframes and instrument modules that have been upgraded. Please note that all instrument modules to be used in a TLA mainframe with Version 4.4 application software must have the instrument module firmware upgraded; otherwise, the TLA application software will not recognize the instrument module. The firmware process, however, is easy-to-do and takes about 5 minutes per instrument module. All of the firmware images are part of each TLA application software release.

TLA Backup Media

Each TLA logic analyzer comes standard with the Microsoft Windows 2000 Professional Operating System and TLA applications software preloaded on the hard disk. CD-ROMs for both Windows and the Version 4.4 TLA applications software are also provided as backup media.

The TLAVu and PatGenVu offline data viewers are on the backup media CD-ROMs for installation on any Windows 2000/XP PC.

Please contact your local Tektronix account manager for complete instructions and information on ordering a TLA5KUP Field Upgrade Kit. Have the model number of your TLA mainframe ready when you call.

TLA5KUP

TLA5000 Series Logic Analyzer Field Upgrade Kit

TLA5KUP Option 15 - includes an iView external oscilloscope interface with SMB-to-BNC adapter, TLA5KUP Mainframe Field Upgrade Kit Instruction Manual.

A000_1649-N

Option 15 - iView External Oscilloscope Cable for TLA Family of Logic Analyzers.

TLA5KUP Option 35 - includes Version 4.4 TLA Application SW, Windows 2000 Professional, EasyRestore license, Win2k Pro license, Win2k Pro certificate of authenticity, CheckIt Utilities, TLA Family User Manual, TLA Mouse Pad, SW Revision labels, TLA5KUP Mainframe Field Upgrade Kit Instruction Manual.

A000_1652-N

Option 35 - Version 4.4 TLA Application Software and Windows 2000 Professional Operating System*6.

TLA5KUP Option 36 - includes Version 4.4 TLA Application SW, CheckIt Utilities, TLA Family User Manual, TLA Mouse Pad, SW Revision labels, TLA5KUP Mainframe Field Upgrade Kit Instruction Manual.

A000_1653-N

Option 36 - Version 4.4 TLA Application Software*6.

Option IF - Tektronix Service Center Installation.

TLA5KUP Field Upgrade Kit User Manual - Order 075-0835-xx.

 

*6 Please refer to the section, "Current TLA Software Versions" for the version numbers of current production TLA software.