Tektronix Logic Analyzers
TLA700 Series Mainframes
Les produits figurant sur cette fiche technique ne sont plus vendus par Tektronix.
Référez-vous à Tektronix Encore pour les équipements de test reconditionnés.
Consultez l'assistance et les informations de garantie pour ces produits.
Features & Benefits
- Modular Mainframes Provide Flexibility and Expandability
- Utilize Logic Analyzer or Pattern Generator Modules
- Expansion Mainframe Supports Up to 8160 Logic Analyzer Channels, 60 Independent Buses
- All Measurement Modules are Fully Interchangeable Between Portable and Benchtop Mainframes
- Integrated View (iView™) Capability Provides up to 6 GHz, 20 GS/s, and 32 Mb Analog Acquisition with a Stand-alone Tektronix TDS Digital Storage Oscilloscope
- Microsoft® Windows® 2000 Professional PC Platform Provides Familiar User Interface With Network Connectivity
- View Data in Waveform, Listing, Source Code, Histogram (Performance Analysis) Displays to Perform Cross-domain Analysis
- Remote Control Using Microsoft® COM/DCOM Technology Supports Advanced Data Analysis
- Broad Processor and Bus Support
- TLAVu and PatGenVu Off-line Analysis Capability for Viewing Data and Creating Setups on a Separate PC
Applications
- Hardware Debug and Verification
- Processor/Bus Debug and Verification
- Embedded Software Integration, Debug and Verification
Breakthrough Solutions for Real-time Digital Systems Analysis
The TLA715 and TLA721 mainframes are modular mainframes that accept TLA7Axx and TLA7Lx/Mx/Nx/Px/Qx logic analyzer modules, as well as TLA7PG2 pattern generator modules. The TLA715 and TLA721 can be used in conjunction with a TLA7XM expansion mainframe to provide solutions for large numbers of buses and high channel count requirements.
The TLA715 and TLA721 mainframes are built on a Microsoft® Windows® 2000 Professional PC platform that offers a familiar work environment. TLA applications operate like any other PC application.
The TLA715 and TLA721 mainframes come standard with dual display capability for extended desktop viewing, in addition to an internal CD-RW, hard disk and PC card slots for expansion. A replaceable hard disk is standard on both mainframes, ideal for security or enabling individual team members to store personal setups and data. Trigger in/out connections provide an interface to other external instrumentation, such as TDS oscilloscopes, for correlating measurement results.
Characteristics
General (TLA715, TLA721, TLA7XM)
Instrument Slots - TLA715: Holds 4 single-wide or 2 double-wide modules.
TLA721: Holds 10 single-wide or 5 double-wide modules.
TLA7XM: Holds 12 single-wide or 6 double-wide modules.
Quantity of TLA7XMs - The TLA700 Series Mainframes can support multiple TLA7XM mainframes.
TLA715: Up to two TLA7XM mainframes can be used providing 13 dual/26 single instrument slots*2 *3.
TLA721: Up to ten TLA7XM mainframes can be used providing 60 dual/120 single instrument slots*2 *3.
Mainframe |
LA*1 |
PG*1 |
---|---|---|
Max channels per module |
136 ch. |
64 ch. |
TLA715 |
1,768 |
832 |
TLA721 |
8,160 |
3,840 |
*1 All logic analyzer (LA) and pattern generator (PG) modules are dual-wide or occupy two single-wide slots.
*2 TLA7XM Expansion Module occupies one single-wide slot in both the TLA715/TLA721 mainframes and the TLA7XM expansion mainframe.
*3 Using a TLA7XM expansion mainframe with an existing TLA714/TLA720 mainframe requires Version 4.0 or higher TLA application software. TLA720 benchtop mainframes, S/N: B019999 and lower, require TLA7UP Option 09 TLA720 Benchtop Mainframe Upgrade. Please refer to the TLA Upgrade Guide for further details.
Example of TLA721 with ten TLA7XM Mainframes.
For configurations beyond ten TLA7XM expansion mainframes, please contact your local Tektronix account manager.
TLA700 PC Characteristics (TLA715 and TLA721)
Operating System - Microsoft Windows 2000 Professional.
Processor - Intel Pentium III.
Chipset - Intel 815E.
DRAM - 512 MB SDRAM.
Display Memory - 4 MB.
Dual Monitor Support - 1600 x 1200 Resolution.
Sound - Built-in PC speaker transducer; multimedia sound can be added via PC Card interface.
Replaceable Hard Disk Drive - TLA715: 40 GB.
TLA721: 40 GB.
CD ROM - Internal 8/4/32 CD-RW.
Floppy Disk Drive - Built-in 3.5 in. 1.44 MB drive.
TLA700 Integral Controls (TLA715 only)
Front-Panel Display - Size: 10.4 in. diagonal.
Type: Active-matrix color TFT LCD with backlight.
Resolution: 800 x 600.
Colors: 16.8 M (true color).
Simultaneous Display Capability - Both the front-panel and one external display can be used simultaneously at 800 x 600 resolution.
Front-panel Knobs - Special function knobs for instrument control.
Front-panel QWERTY Keypad - Mini-QWERTY keypad and Hex keypad.
Front-panel Pointing Device - Trackball.
TLA700 External Peripheral Interfaces (TLA715 and TLA721)
External Display Port Type - (2) Female DB15 connectors.
External Display Resolution - Up to 1600 x 1200 non-interlaced at 256 colors, for both primary and secondary displays.
External Display Compatibility - DDC2B (dynamic display configuration 2).
External Keyboard Port Type - PS2 mini-DIN.
External Mouse Port Type - PS2 mini-DIN.
Parallel Interface Port Type - IEEE 1284-C connector (comes standard with adapter to female DB25 connector).
Parallel Interface Modes - Centronics mode, EPP (Extended Parallel Port), ECP (Microsoft high-speed mode).
Serial Interface Port Type - Male DB9.
PC Card (CardBus) Slot Types - Two slots, two PC Card Type I/II or one PC Card Type III.
USB Port - Two (2).
TLA715 Portable Mainframe.
TLA721 Benchtop Mainframe.
TLA7XM Expansion Mainframe.
Integrated View (iView™) Capability
TLA mainframe configuration requirements - TLA714/720/715/721 Series mainframes, TLA520x instruments, and TLA6XX instruments.
TLA App S/W V 4.1 or greater.
256 MB DRAM Minimum, 512 MB recommended.
TDS configuration requirements - The iView™ cable does not fully connect to the TDS1000/2000 Series oscilloscopes without a GPIB extender. Tektronix recommends a standard GPIB cable as an extender, or order a cable extender (National Instruments part number 181638-1). TDS2CMAX Communications Extension Module is required for iView capability on any TDS1000/2000 Series. TDS3GM GPIB/RS232 Interface Module required for iView capability on any TDS3000 series. TDS3GV GPIB/RS232/VGA Interface Module required for iView capability on any TDS3000B series. If using TLA7Axx iConnect with a TDS6404, TDS6604, TDS7154, TDS7404, CSA7154 or CSA7404 oscilloscope, four TCA-BNC connectors are required to be compatible with BNC cables from the TLA7Axx module.
Number of TDS oscilloscopes that can be connected to a TLA system - 1.
External Oscilloscopes Supported - TDS1002, TDS1012, TDS2002, TDS2012, TDS2014, TDS2022, TDS2024.
TDS3012, TDS3014, TDS3032, TDS3034, TDS3052, TDS3054.
TDS3012B, TDS3014B, TDS3032B, TDS3034B, TDS3052B, TDS3054B.
TDS5032, TDS5034, TDS5052, TDS5054, TDS5104.
TDS6404, TDS6604.
TDS7054, TDS7104, TDS7154, TDS7404.
TDS684C, TDS694C.
CSA7154, CSA7404.
TDS754C, TDS784C, TDS724D, TDS754D, TDS784D, TDS794D.
TLA Connections - USB, Trigger In, Trigger Out, Clock Out.
TDS Connections - GPIB, Trigger In, Trigger Out, Clock In (when available).
Setup - iView™ external oscilloscope wizard automates setup.
Data Correlation - After TDS oscilloscope acquisition is complete, the data is automatically transferred to the TLA and time correlated with the TLA acquisition data.
Deskew - TDS and TLA data is automatically deskewed and time correlated when using the iView™ external oscilloscope cable.
iView™ External Oscilloscope Cable Length - 2 m.
TLA715 Series with TDS7000 Series oscilloscope.
Symbolic Support
Number of Symbols/Ranges - Unlimited (limited only by amount of virtual memory available on TLA).
Object File Formats Supported -
- IEEE695
- OMF 51, OMF 86, OMF 166, OMF 286, OMF 386
- COFF
- Elf/Dwarf 1 and 2
- Elf/Stabs
- TSF (if your software development tools do not generate output in one of the above formats, TSF or the Tektronix symbol file, a generic ASCII file format is supported. The generic ASCII file format is documented in the TLA User Manual). If a format is not listed, please contact your local Tektronix representative.
External Instrumentation Interfaces
System Trigger Output - Asserted whenever a system trigger occurs (TTL-compatible output, back-terminated into 50 Ω).
System Trigger Input - Forces a system trigger (triggers all modules) when asserted (TTL-compatible, edge-sensitive, falling-edge latched).
External Signal Output - Can be used to drive external circuitry from a module's trigger mechanism (TTL-compatible output, back-terminated into 50 Ω).
External Signal Input - Can be used to provide an external signal to arm or trigger any or all modules (TTL-compatible, level-sensitive).
P6041 External Signal Cable Length - (SMB to BNC adapter cable, two each TLA721 only) 1.1 m (42 in.).
Power
TLA715 - Voltage range/frequency: 90-250 VAC at 45-66 Hz.
100-132 VAC at 360-440 Hz.
Input current: 6 A maximum at 90 VAC (70 A surge).
Power consumption: 600 W maximum.
TLA721 and TLA7XM - Voltage range/frequency: 90-250 VAC at 45-66 Hz, 100-132 VAC at 360-440 Hz.
Input current: 16.5 A maximum at 90 VAC (70 A surge).
Power consumption: 1,450 W maximum.
Physical Characteristics
TLA715 Portable |
||
---|---|---|
Dimensions |
mm |
in. |
Weight |
kg |
lb. |
TLA721 Benchtop & TLA7XM Expansion |
||
Dimensions |
mm |
in. |
Weight |
kg |
lb. |
Height |
235 |
9.25 |
Width |
432 |
17 |
Depth |
455 |
17.5 |
Net (w/o modules) |
11.4 |
25 |
Shipping (typical) |
25.5 |
56 |
Height |
346 |
13.65 |
Width |
425 |
16.7 |
Depth |
673 |
26.5 |
Net (w/o modules) |
22.7 |
50 |
Shipping (typical) |
51.8 |
114 |
TLA715 Portable Mainframe.
TLA721 and TLA7XM Benchtop and Expansion Mainframes.
TLA721 and TLA7XM Benchtop and Expansion Mainframes with TLA721/TLA7XM Rackmount Kit.
Environmental
Temperature - Operating: +5 °C to +50 °C.
Nonoperating: -20 °C to +60 °C.
Humidity - 20% to 80%.
Operating: ≤30 °C; 80% relative humidity (29 °C maximum wet bulb temperature).
Nonoperating: 8% to 80% (29 °C maximum wet bulb temperature).
Altitude - Operating: -1,000 ft. to 10,000 ft. (-305 meters to 3,050 meters).
Safety - UL3111-1, CSA1010.1, EN61010-1, IEC61010-1.
LACART Instrument Cart (adjustable probe skyhook not shown).
K4000 Instrument Cart.
Ordering Information
TLA715
Dual Monitor Portable Mainframe.
Includes: Wheel mouse, keyboard, LAN PC Card, front-panel cover, accessory pouch, two dual-wide panel fillers for empty slots, printer adapter, software, certificate of calibration and one-year warranty (return to Tektronix), power cord, and user manual. Please specify power plug when ordering.
TLA721
Dual Monitor Benchtop Mainframe.
Includes: Wheel mouse, keyboard, LAN PC Card, five dual-wide panel fillers for empty slots, printer adapter, two P6041 SMB to BNC adapter cables; software, certificate of calibration and one-year warranty (return to Tektronix), power cord, and user manual. Please specify power plug when ordering. Display is not included.
TLA7XM
Expansion Mainframe.
If installing a TLA7XM expansion mainframe into a TLA700 Series mainframe, please consult the TLA Family Upgrade Guide for upgrade information.
Includes: Two expansion modules, three expansion cables, six dual-wide panel fillers for empty slots, one single-wide panel filler for empty slot, statement of compliance and one-year warranty (return to Tektronix), power cord, and user manual. Please specify power plug when ordering.
TLA715/721 Options
Opt. 1C - Add iView™ external oscilloscope interface kit (012-1614-01).
Opt. 1K - Add LACART logic analyzer cart.
Opt. 3M - Add 18 in. 1280x1024 flat-panel display (119-6568-00).
Opt. 4M - Add 21 in. 1600x1200 flat-panel display (119-6569-00).
Power Plug Options
Opt. A0 - North America power.
Opt. A1 - Universal EURO power.
Opt. A2 - United Kingdom power.
Opt. A3 - Australia power.
Opt. A4 - 240 V, North America power.
Opt. A5 - Switzerland power.
Opt. A6 - Japan power.
Opt. A10 - China power.
Opt. A99 - No power cord or AC adapter.
Language Options for User Manuals
Opt. L0 - English
Opt. L10 - Russian
Opt. L99 - No Manuals
TLA715/TLA721/TLA7XM Factory Configuration
Opt. 88 - Install modules in mainframe at factory (excludes merging of Logic Analyzer modules).
TLA704/714/715 TLA711/720/721 TLA7XM Optional Accessories
Logic Analyzer Cart - LACART, K4000.
TLA711 Rackmount Kit - Order 020-2197-00.
TLA720/TLA721/TLA7XM Rackmount Kit - Order 020-2369-00.
TLA704/714/715 Wheeled Transport Case - Order 016-1522-00.
TLA711/720/721/TLA7XM Wheeled Transport Case - Order 016-1651-00.
Wheeled Transport Case for 18 in. 1280x1024 Flat-panel Display - Order 016-1895-00.
Wheeled Transport Case for 21 in. 1600x1200 Flat-panel Display - Order 016-1896-00.
83 Key Notebook Keyboard, PS2-Compatible - Order 118-9402-00.
TLA7QS - TLA Family training package. (TLA700 configuration required: 102-Channel logic analyzer module (required) plus 2-Channel digitizing oscilloscope module (optional) plus 64-Channel pattern generator module (optional)).
TLA7QS Technical Reference Support Kit - Order 020-2211-02.
Displays
18 in. 1280x1024 Flat-panel Display with U.S. Standard, 120 V; 60 Hz Power Plug - Order 119-6568-02.
20 in. 1600x1200 Flat-panel Display with U.S. Standard, 120 V; 60 Hz Power Plug - Order 119-6569-01.
Power Cord Options for Displays
Power Cord, IEC320 C5 Universal Euro, Straight - Order 161-0311-00.
Power Cord, IEC320 C5 UK, Straight - Order 161-0312-00.
Power Cord, IEC320 C5 Australian, Straight - Order 161-0313-00.
Power Cord, IEC320 C5 Switzerland, Straight - Order 161-0314-00.
TLA700 Series Manuals
TLA Family User Manual - Order 071-1236-00 (for Version 4.3 TLA application software).
TLA7QS QuickStart™ Training Manual - Order 070-9717-05.
TLA700 Series Service Manuals and Test Fixtures
TLA715 Service Manual (includes performance verification and adjustment procedures) - Order 071-0913-01.
TLA721/7XM Service Manual (includes performance verification and adjustment procedures) - Order 071-0912-01.
TLA700 Series Mainframe Upgrades
You can upgrade the operating system, TLA application software, increase DRAM and hard disk, add existing modules as well as other new capabilities to your existing TLA714/715/720/721 mainframe.
Please refer to the TLA Family Upgrade Guide for further details.
Service Options
Opt. C3 - Calibration Service 3 Years
Opt. C5 - Calibration Service 5 Years
Opt. D1 - Calibration Data Report
Opt. D3 - Calibration Data Report 3 Years (with Option C3)
Opt. D5 - Calibration Data Report 5 Years (with Option C5)
Opt. R3 - Repair Service 3 Years
Opt. R5 - Repair Service 5 Years
Opt. IN - Product Installation Service
Opt. S1 - On-site Service 1 Year
Opt. S3 - On-site Service 3 Years (with R or C Option)