FAQ
If I rackmount my AWG2000 series generator+ do I lose access to the floppy disk on the side of the AWG?
No. The floppy disk drive is moved out to the rackmount front panel as part of the rackmount kit.

Diese FAQs beziehen sich auf:
62756
I've heard that you can capture up to eight channels single shot with the 11403. Is this possible? What are the limitations?
Yes, it is possible. As was explained in the answer to question #1, up to eight traces can be defined. If the combination of time per divisions setting and record length are such that the sample interval is 5 µsecs or less the 11403 will capture all eight …

Diese FAQs beziehen sich auf:
62751
I'm trying to save a curve from my 370A to it's floppy but I'm getting an error message - what's going on?
The floppy drives in 370A/371A support 720K diskettes only. To use 1.44M media, tape over the empty hole in the upper left corner of the diskette (i.e. the one opposite the write protect switch). The 370B and 371B use standard 1.44M drives.

Diese FAQs beziehen sich auf:
62746
I'm considering purchasing Metrics ICS software for use with my 370A/371A curve tracer. How do I order it?
Contact Metrics Technology at http://www.metricstech.com/

Diese FAQs beziehen sich auf:
62741
I hooked up a 50-ohm cable between channel 1 on the 11A32 amplifier and the Calibrator-out BNC on my 11403 and hit AUTOSET. All I get is about 6 mV of noise at around 5 msecs per division. Is the scope in need of repair?
From the symptoms that you have described, there is nothing wrong with your 11403. The calibrators on the 11400 Series oscilloscopes have no output except when Probe Deskew is selected and running, or when you run certain calibration routines.

Diese FAQs beziehen sich auf:
62736
I have been looking at used oscilloscopes. The 2465 has so many varieties and options. What are the differences between the 2465+ 2465A+ and 2465B+ and what are the options?
There were several updates to the 2465 products. Major changes were designated by adding first an A, then a B. There were also several options available that served specific markets. The table below shows the bandwidth difference between models and the …

Diese FAQs beziehen sich auf:
62731
I have a 73A156 GPIB Slot 0+ which has CIIL/MATE programming. What do I need to do to communicate with this old Slot 0 controller.
The key to working with this old slot zero is to setup repeat addressing for the GPIB interface. This is an IBCONF command with parameters 6 and 1.

Diese FAQs beziehen sich auf:
62726
I get an error when I recall a setup.
After an application software upgrade, there may be instances where recalling a setup may result in "File not found" error. This is because there is a Ref memory active in the setup and the Ref memory has been erased. To solve the problem, save a waveform …

Diese FAQs beziehen sich auf:
62721
I am getting the diagnostic error E5622 on my 11800. What does this indicate?
The error code indicates a communication problem with the Time Base Board and is usually caused by dead NVRAM batteries.  There are two NVRAM chips on this board and they plug into a socket that has control and battery capabilities.  When the batteries go …

Diese FAQs beziehen sich auf:
62716
I am capturing and storing waveforms in the 11402+ in the internal memory. How many waveforms can I save before I run out memory?
The number of waveforms that can be stored depends on several factors. The record length, instrument configuration, number and complexity of stored settings all contribute to setting the number of waveforms that can be stored. The table below will serve as …

Diese FAQs beziehen sich auf:
62711