Characteristics
Warranted
|
Characteristic
|
Description
|
|
Bandwidth
|
DC to ≥20 MHz (-3 dB). Derate with Frequency. See
Figure 1. (Calculated from Rise Time BW = .35/Rise Time)
|
|
Rise Time
|
≤17.5 ns
|
|
Max RMS Current
|
150 A
|
|
Max Peak Pulse Current
|
500 A
|
|
Minimum Sensitivity
|
5 mA (on oscilloscope’s 1 mV/div setting)
AC Coupling (on oscilloscopes that support AC/DC coupling)
|
|
Current Ranges
|
25 A and 150 A
|
|
Max Bare-wire Voltage
|
600 VRMS CAT I and II
300 VRMS CAT III
|
Typical
|
Characteristic
|
Description
|
|
DC Accuracy
|
±1% Typical
3% Warranted
|
|
Max Amp-second Product
|
|
25 A Range
|
3,000 Aµs
|
|
150 A Range
|
15,000 Aµs
|
|
Insertion Impedance
|
0.03 Ω at 1 MHz
|
|
0.075 Ω at 5 MHz
|
|
.125 at 10 MHz
|
|
.3 at 20 MHz
|
|
Signal Delay
|
21 ns
|
|
Displayed RMS Noise
|
≤500 μARMS (probe only)
|
Environmental
|
Characteristic
|
Description
|
|
Temperature
|
|
Operating
|
0 ºC to +50 ºC
|
|
Nonoperating
|
-40 ºC to +75 ºC
|
|
Humidity
|
|
Operating
|
5% to 95% RH (Relative Humidity) at up to +30 ºC
5% to 85% RH above 30 ºC up to +50 ºC, noncondensing
|
|
Nonoperating
|
5% to 95% RH (Relative Humidity) at up to +30 ºC
5% to 85% RH above 30 ºC up to +75 ºC, noncondensing
|
|
Altitude
|
|
Operating
|
Up to 2,000 meters (6,560 feet)
|
|
Nonoperating
|
Up to 12,000 meters (40,000 feet)
|
Physical Characteristics
|
Dimension
|
Meters
|
Inches
|
|
Cable Length
|
2 meters
|
79 in.
|
|
Probe head size
|
|
Length
|
26.8 cm
|
10.55 in.
|
|
Width
|
4.1 cm
|
1.6 in.
|
|
Height
|
15.6 cm
|
6.13 in.
|
|
Max Conductor Diameter
|
21 mm x 25 mm
|
0.83 in. x 1.0 in.
|
|
Weight
|
kg
|
lb.
|
|
Shipping
|
.7865
|
1.734
|
|
Power Requirements
|
TCP0150 is powered directly by oscilloscopes
with the TekVPI interface
|
Recommended Oscilloscopes
Oscilloscopes with the TekVPI probe interface.
Note: For best probe support, download and install the latest
version of the oscilloscope software from www.tektronix.com
Figure 1.
Figure 2.
Figure 3: Do not apply currents greater than the max continuous current
for more than 10 seconds to minimize heating effects.