Can options be removed from a TekSelect product? Yes, but only if it is a soft option activated by a keycode or dongle or if the option being removed is a separate model (e.g. probe, cart, etc.) and the unit does not have a delivery of 1 week or less. |
835656 |
Can power cord or manual language options be changed on a TekSelect product? Power cord options (A0-A99) or manual language options (L0-L9) can be modified to match your local language and power source. We will make these changes regardless of the delivery lead-time advertised. |
835657 |
Can the minimum block sizes for the DTG Pattern Generators be worked around? Yes, by selecting the software sequencer mode in the Sequence menu you can get smaller minimum block sizes. There will be some imposed limitations and they are documented on page 1-85 of the DTG5078 & DTG5274 & DTG 5334 Data Timing Generator... This FAQ applies to: DTG5078, DTG5334 |
835658 |
Can the TLA600 run version 5.0 or above of the TLA software? Windows 2000 and application software v4.4 was the last supported software configuration on the TLA600. This FAQ applies to: TLA601, TLA602, TLA603, TLA604, TLA611, TLA612, TLA613, TLA614, TLA621, TLA622, TLA623, TLA624 |
835659 |
Can the TLA714 be upgraded from Windows 2000 to Windows XP and still run version 4.4 of the TLA software? The TLA714 is not supported under Windows XP. Windows 2000 and application software v4.4 was the last supported software configuration.
This FAQ applies to: TLA714 |
835660 |
Can the TLA714 run version 5.0 or above of the TLA software? Windows 2000 and application software v4.4 was the last supported software configuration on the TLA714.
This FAQ applies to: TLA714 |
835661 |
Can the TLA720 be upgraded from Windows 2000 to Windows XP and still run version 4.4 of the TLA software? The TLA720 is not supported under Windows XP. Windows 2000 and application software v4.4 was the last supported software configuration. |
835662 |
Can the TLA720 run version 5.0 or above of the TLA software? Windows 2000 and application software v4.4 was the last supported software configuration on the TLA720. |
835663 |
Does SATA provide better performance than Parallel ATA? Serial ATA supports data rates up to 150 MB/s, versus the industry standard of 100 MB/s for Parallel ATA. The new interface also provides for command queuing to further boost system performance. |
835664 |
For 1000BT what are the various test points for corresponding test modes? For 1000BASE-T PHY testing, the DUT should be tested in various modes. For 1000Base-T, the application tests the DUT in compliance with IEEE standard 802.3 ab. For each test, set the DUT to test mode specified: |