Characteristics
Bandwidth - DC to ≥120 MHz
Rise Time - ≤2.92 ns
Max RMS Current - 30 A
Max Peak Pulse Current - 50 A
Minimum
Sensitivity -
1 mA (on oscilloscopes that support 1 mV/div
setting)
AC Coupling (on oscilloscopes that support AC/DC coupling)
Current Ranges - 5 A and 30 A
Max Bare-wire
Voltage - Use insulated wire only
Typical Characteristics
DC Accuracy -
±1% typical
±3% warranted
Max Amp-second Product - 500 A*µs (in 30 A Range)
Insertion Impedance -
1 mΩ at 10 kHz
3.5 mΩ
at 100 kHz
0.08 Ω at 1 MHz
0.15 Ω at 10 MHz
0.7 Ω
at 100 MHz
0.85 Ω at 120 MHz
Signal Delay - 14.5 ns
Environmental
Temperature -
Operating:
0 ºC to +50 ºC
Nonoperating: –40 ºC to +75 ºC
Humidity -
Operating: 5% to 95% Relative Humidity (RH) at
up to +30 °C; 5% to 85% RH above 30 °C up to +50 °C, noncondensing
Nonoperating: 5% to 95% Relative Humidity (RH) at up to +30 °C;
5% to 85% RH above 30 °C up to +75 °C, noncondensing
Altitude -
Operating: Up to 3,000 m (10,000 ft.)
Nonoperating:
Up to 12,192 m (40,000 ft.)
Regulatory
Compliance
Labeling -
CE (European Union)
WEEE (European Union)
Physical Characteristics
|
Probe Head Size
|
cm
|
in.
|
|
Height
|
3.2
|
1.25
|
|
Width
|
1.6
|
0.625
|
|
Length
|
20
|
7.77
|
|
Other Dimensions
|
|
Cable Length
|
200
|
79
|
|
Max Conductor Diameter
|
0.38
|
0.15
|
|
Weight
|
kg
|
lb.
|
|
Shipping
|
1.55
|
3.44
|
|
Power Requirements
|
|
TCP0030 is powered directly by oscilloscopes with
the TekVPI™ interface
|
Recommended Oscilloscopes
Oscilloscopes
with the TekVPI™ probe interface.
Note: For best probe
support, download and install the latest version of the oscilloscope
software from www.tek.com.
Standard Warranty
One year parts and labor.