Recommended Test Equipment for HDMI Compliance Testing per CTS (Compliance Test Specification) V1.3c

HDMI Sink Test

Recommended Equipment Quantity
Oscilloscope DSA70804, DSA71254, DSA71604 or DSA72004 with Opt 2XL; or
DPO70804, DPO71254, DPO71604, or DPO72004 with Opt 2XL
1
Other Supported Oscilloscopes 1, 2 TDS6804B, TDS6124C and TDS6154C 1
Software TDSHT3 - HDMI compliance software (support for CTS V1.3b requires software Version 3.3.0 or higher. Support for CTS V1.3b1 and support of 4-channel measurement requires software Version 4.0 or higher) 1
Probes P7313SMA differential SMA probe - use for all differential and single-ended measurements 2
Data Generator DTG5334 with (3) DTGM30 modules 1 set
Other Supported Data Generators3 DTG5274 with (3) DTGM30 modules can be used but will only support HDMI testing at limited resolution and clock/data rate 1 set
Jitter Generator AWG7122B with opt 01 - supports both standard (combined) and Optional (separate clock/data) jitter insertion methods 1
Other Supported Jitter Generators AFG3102 - this support only the standard (combined clock/data) jitter insertion method 1
TDR System DSA8200 with (1) 80E03 and (1) 80E04 module (for SINK Differential Impedance test) 1
Test Fixtures (TPAs) ET-HDMI-TPA-S - HDMI Type A fixture set for Transmitter Test, Receiver Test, and Cable Test. Order from Efficere Technologies. 1 set
Connector Bias-Tees to shift AWG7122B direct clock output to TMDS levels. Order individually as ZX85-12G-S+ from Mini-Circuits 2
Cables SMA cables 12
Adapter BNC to SMA adapter 1
Interface NI-GPIB-USB -A/B/HS with Driver Software from National Instruments. Type B/HS is recommended for use with DPO/DSA70000 Series oscilloscopes. 1
Power Supply Power supply 5V 1
Filters Transition Time Converters from Picosecond Pulse Labs

Ordering information:

Clock Speed Rise Time Filter Part Number
27 MHz 430 ps 5915-100-430PS
74.25 MHz 430 ps 5915-100-430PS
148.5 MHz 200 ps 5915-100-200PS
222.75 MHz 120 ps 5915-100-120PS
335.00 MHz   No filter required

Please note that 5915-100-xxx type filter has Female connectors (jack) on both input and output sides. One Male-Male (plug-plug) adapter will be needed for each TTC unit to be connected to DTG output or cable emulator unit directly. Unit with different shape of connectors Female-Male (jack-plug) is available by ordering as 5915-110-xxx, but will be less flexible in connection.

6 sets

1 Oscilloscopes with bandwidth less than 8 GHz will only support HDMI testing at limited resolution and clock/data rates.

2 16M per channel or greater record length is required for HDMI Compliance test.

3 If the Jitter Generator used is an AFG3102 or an AWG710B, then a single DTGM32 module is also required for use with either DTG model.