Tektronix » Applications » Embedded Systems » Memory » DDR Recommended Equipment

DDR Recommended Equipment

DDR achieves greater bandwidth than the preceding single data rate SDRAM by transferring data on the rising and falling edges of the clock signal (double pumped). Effectively, it doubles the transfer rate without increasing the frequency of the clock.

Supported SDRAM standards
SDRAM Data Rate
MT/S
Clock
MHz
VDD
V
LP-DDR 166 83 1.8
DDR-200 200 100 2.5
DDR-266 266 133 2.5
DDR-333 333 166 2.5
DDR-400 400 200 2.5

DDR Electrical Validation and Debug

Recommended for DDR 1 Electrical Validation and Debug Quantity
Oscilloscope Tektronix Real Time DPO/DSA Oscilloscope (DPO7254 or higher) 1
Analysis Software Opt. DDRA - DDR Memory Bus Analysis
Opt. ASM - Advanced Event Search And Mark
Opt. DJA - DPOJET Jitter and Eye Diagram Analysis - Advanced
1 each
Active Differential Probe P7300 or P7500 Series Differential Probes 2 or more

DDR Digital Validation and Debug

Recommended for DDR Digital Validation and Debug* Quantity
Logic Analyzer Mainframe TLA7012 Portable or TLA7016 Benchtop 1
Logic Analyzer Module* TLA7AA4 Module 1 or more*
Test Fixture/Support Package Nexus Technology NEXVu DDR Support  
Probing Different options are available: Tektronix midbus probes or Nexus slot interposer and instrumented DIMMs  
*Exact configuration may vary depending on your DDR standard and speed. Please contact your local Tektronix Sales representative for a detailed recommendation.

DDR Circuit Board Verification & Signal Path Characterization

Recommended for DDR 1, 2 and 3 Circuit Board Verification & Signal Path Characterization Quantity
Sampling Oscilloscope DSA8200 Sampling Oscilloscope 1
Modules 80E04 or 80E10 TDR Sampling Module 1
Analysis Software 80SSPAR IConnect S-parameter Software 1