Download

Download Manuals, Datasheets, Software and more:

DOWNLOAD TYPE
MODEL or KEYWORD

Feedback

I am using the 80SSPAR software and the Iconnect S-parameter Wizard software and only getting 4 GHz (frequency range). Why don't I get a higher Fmax frequency?

Question :

I am using the 80SSPAR software and the Iconnect S-parameter Wizard software and only getting 4 GHz (frequency range). Why don't I get a higher Fmax frequency?

Answer :

The available frequency range is determined by the risetime of the reference waveform.  To get faster risetime, use shorter SMA cables and shorter traces on the test / cal fixture.


This FAQ Applies to:

No product series

Product:

FAQ ID 59526

View all FAQs »