The MSO/DPO2000B Mixed Signal Oscilloscope series is the most powerful scope in its class with advanced debug features at an entry-level price. With as many as 20 channels, you can analyze analog and digital signals with a single instrument. Combine that with automated serial and parallel bus analysis and innovative Wave Inspector® controls, you get the tools you need to speed up your debugging.

Bandwidth

Up to 200 MHz

Record Length

1 Mpoints

Analog channels

2 or 4

Sample Rate

1 GS/s on all channels

 

Find, Debug and Analyze Faster

Thumbnail

Look at many points in your design with 4 analog and 16 digital channels plus 2 bus waveforms. Find anomalies fast with digital phosphor display and 125 trigger combinations, and use Wave Inspector to pan through 1M waveform points, zoom in, mark points of interest, and navigate from mark to mark. Plus: FilterVu reduces noise, not glitches.

Forget About Manually Decoding Serial Buses

Thumbnail

Reduce errors and save time with automatic serial bus decoding. Plus, optional serial triggering and decoding modules automate triggering on specific packet content, then displays data in analog waveforms and bus views for quick insights.  Also available: options for the leading serial buses in automotive, embedded design and computer applications.

A Probe Interface that Broadens the Possibilities

Thumbnail

The Tek VPI probe interface provides wide application coverage and you don't have to worry about scale factors. Use a wide range of active and current probes that automatically communicate scale factors, enable simple deskewing and provide probe information on the scope display.

Simplify Mixed Signal Debugging

Thumbnail

Debug mixed signal designs with up to 4 analog and 16 digital channels, all time-correlated. Combine digital channels to show parallel buses or decode serial buses. Add in the innovative P6316 logic probe to make it easy to connect to your design and keep track of the signals.

Highlights

  • 16 fully integrated channels, all with 1GS/s sampling rate.
  • Easy to use logic analyzer functionality.
  • Define parallel or serial buses for triggering and decoding.
  • Simple visualization with waveform grouping and color coding.

 

Models

Model Analog Bandwidth Sample Rate Record Length Analog Channels Digital Channels List Price
DPO2002B 70 MHz 1 GS/s 1 Mpoints 2 - US $1,310
Configure & Quote
DPO2012B 100 MHz 1 GS/s 1 Mpoints 2 - US $1,630
Configure & Quote
MSO2002B 70 MHz 1 GS/s 1 Mpoints 2 16 US $2,050
Configure & Quote
DPO2004B 70 MHz 1 GS/s 1 Mpoints 4 - US $2,090
Configure & Quote
DPO2022B 200 MHz 1 GS/s 1 Mpoints 2 - US $2,300
Configure & Quote
MSO2012B 100 MHz 1 GS/s 1 Mpoints 2 16 US $2,410
Configure & Quote
DPO2014B 100 MHz 1 GS/s 1 Mpoints 4 - US $2,440
Configure & Quote
MSO2004B 70 MHz 1 GS/s 1 Mpoints 4 16 US $2,750
Configure & Quote
DPO2024B 200 MHz 1 GS/s 1 Mpoints 4 - US $2,930
Configure & Quote
MSO2022B 200 MHz 1 GS/s 1 Mpoints 2 16 US $3,070
Configure & Quote
MSO2014B 100 MHz 1 GS/s 1 Mpoints 4 16 US $3,100
Configure & Quote
MSO2024B 200 MHz 1 GS/s 1 Mpoints 4 16 US $3,610
Configure & Quote
ModelDPO2002B
List PriceUS $1,310
Analog BandwidthSample RateRecord Length
70 MHz1 GS/s1 Mpoints
Analog Channels
2
ModelDPO2012B
List PriceUS $1,630
Analog BandwidthSample RateRecord Length
100 MHz1 GS/s1 Mpoints
Analog Channels
2
ModelMSO2002B
List PriceUS $2,050
Analog BandwidthSample RateRecord Length
70 MHz1 GS/s1 Mpoints
Analog ChannelsDigital Channels
216
ModelDPO2004B
List PriceUS $2,090
Analog BandwidthSample RateRecord Length
70 MHz1 GS/s1 Mpoints
Analog Channels
4
ModelDPO2022B
List PriceUS $2,300
Analog BandwidthSample RateRecord Length
200 MHz1 GS/s1 Mpoints
Analog Channels
2
ModelMSO2012B
List PriceUS $2,410
Analog BandwidthSample RateRecord Length
100 MHz1 GS/s1 Mpoints
Analog ChannelsDigital Channels
216
ModelDPO2014B
List PriceUS $2,440
Analog BandwidthSample RateRecord Length
100 MHz1 GS/s1 Mpoints
Analog Channels
4
ModelMSO2004B
List PriceUS $2,750
Analog BandwidthSample RateRecord Length
70 MHz1 GS/s1 Mpoints
Analog ChannelsDigital Channels
416
ModelDPO2024B
List PriceUS $2,930
Analog BandwidthSample RateRecord Length
200 MHz1 GS/s1 Mpoints
Analog Channels
4
ModelMSO2022B
List PriceUS $3,070
Analog BandwidthSample RateRecord Length
200 MHz1 GS/s1 Mpoints
Analog ChannelsDigital Channels
216
ModelMSO2014B
List PriceUS $3,100
Analog BandwidthSample RateRecord Length
100 MHz1 GS/s1 Mpoints
Analog ChannelsDigital Channels
416
ModelMSO2024B
List PriceUS $3,610
Analog BandwidthSample RateRecord Length
200 MHz1 GS/s1 Mpoints
Analog ChannelsDigital Channels
416
Model Analog Bandwidth Sample Rate Record Length Analog Channels Digital Channels List Price
DPO2002B 70 MHz 1 GS/s 1 Mpoints 2 - US $1,310
Configure & Quote
DPO2012B 100 MHz 1 GS/s 1 Mpoints 2 - US $1,630
Configure & Quote
MSO2002B 70 MHz 1 GS/s 1 Mpoints 2 16 US $2,050
Configure & Quote
DPO2004B 70 MHz 1 GS/s 1 Mpoints 4 - US $2,090
Configure & Quote
DPO2022B 200 MHz 1 GS/s 1 Mpoints 2 - US $2,300
Configure & Quote
MSO2012B 100 MHz 1 GS/s 1 Mpoints 2 16 US $2,410
Configure & Quote
DPO2014B 100 MHz 1 GS/s 1 Mpoints 4 - US $2,440
Configure & Quote
MSO2004B 70 MHz 1 GS/s 1 Mpoints 4 16 US $2,750
Configure & Quote
DPO2024B 200 MHz 1 GS/s 1 Mpoints 4 - US $2,930
Configure & Quote
MSO2022B 200 MHz 1 GS/s 1 Mpoints 2 16 US $3,070
Configure & Quote
MSO2014B 100 MHz 1 GS/s 1 Mpoints 4 16 US $3,100
Configure & Quote
MSO2024B 200 MHz 1 GS/s 1 Mpoints 4 16 US $3,610
Configure & Quote
ModelDPO2002B
List PriceUS $1,310
Analog BandwidthSample RateRecord Length
70 MHz1 GS/s1 Mpoints
Analog Channels
2
ModelDPO2012B
List PriceUS $1,630
Analog BandwidthSample RateRecord Length
100 MHz1 GS/s1 Mpoints
Analog Channels
2
ModelMSO2002B
List PriceUS $2,050
Analog BandwidthSample RateRecord Length
70 MHz1 GS/s1 Mpoints
Analog ChannelsDigital Channels
216
ModelDPO2004B
List PriceUS $2,090
Analog BandwidthSample RateRecord Length
70 MHz1 GS/s1 Mpoints
Analog Channels
4
ModelDPO2022B
List PriceUS $2,300
Analog BandwidthSample RateRecord Length
200 MHz1 GS/s1 Mpoints
Analog Channels
2
ModelMSO2012B
List PriceUS $2,410
Analog BandwidthSample RateRecord Length
100 MHz1 GS/s1 Mpoints
Analog ChannelsDigital Channels
216
ModelDPO2014B
List PriceUS $2,440
Analog BandwidthSample RateRecord Length
100 MHz1 GS/s1 Mpoints
Analog Channels
4
ModelMSO2004B
List PriceUS $2,750
Analog BandwidthSample RateRecord Length
70 MHz1 GS/s1 Mpoints
Analog ChannelsDigital Channels
416
ModelDPO2024B
List PriceUS $2,930
Analog BandwidthSample RateRecord Length
200 MHz1 GS/s1 Mpoints
Analog Channels
4
ModelMSO2022B
List PriceUS $3,070
Analog BandwidthSample RateRecord Length
200 MHz1 GS/s1 Mpoints
Analog ChannelsDigital Channels
216
ModelMSO2014B
List PriceUS $3,100
Analog BandwidthSample RateRecord Length
100 MHz1 GS/s1 Mpoints
Analog ChannelsDigital Channels
416
ModelMSO2024B
List PriceUS $3,610
Analog BandwidthSample RateRecord Length
200 MHz1 GS/s1 Mpoints
Analog ChannelsDigital Channels
416
Low Voltage Single Ended Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TAP1500

Active Probe: 1.5 GHz, 10X, Single-ended, TekVPI

Configure & Quote
Current Probe
Datasheet LinkProbeDescriptionConfigure and Quote
TCP0020

Probe, AC/DC Current; 20 Amp; 50 MHz BW; TekVPI Interface; Certificate of Traceable Calibration Standard

Configure & Quote
TCP0150 Current Probe: 20 MHz, 5 mA to 212 A, AC/DC, TekVPI Configure & Quote
TCP2020 CURRENT PROBE; DC COUPLED, 50 MHZ BW, 20 A, BNC interface Configure & Quote
High Voltage Differential Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TDP0500

Differential Probe: 500 MHz, 5X/50X, +/- 42V, TekVPI

Configure & Quote
TDP1000

Differential Probe: 1 GHz, 5X/50X, +/- 42V, TekVPI

Configure & Quote
THDP0100

Differential PROBE; 100 MHZ TekVPI DIFFERENTIAL HIGH VOLTAGE PROBE

Configure & Quote
THDP0200

Differential PROBE; 200 MHZ TekVPI DIFFERENTIAL HIGH VOLTAGE PROBE

Configure & Quote
TMDP0200

Differential PROBE; 200 MHZ TekVPI DIFFERENTIAL MEDIUM VOLTAGE PROBE;TMPD0200

Configure & Quote
Passive Probe
Datasheet LinkProbeDescriptionConfigure and Quote
TPP0100 Passive Probe: 100 MHz, 10X, BNC Configure & Quote
TPP0200 Passive Probe: 200 MHz, 10X, BNC Configure & Quote
Data SheetAccessoryDescription
119872600 POWER SUPPLY: AC-DC, EXTERNAL; 90-264VAC, 47-63 HZ, IEC320-C14 IN; 12VDC, 5A, CABLE WITH 5.5MM OD 2.1MM ID BARREL OUT; SAFETY CONTROLLED
ACD2000 Soft Carrying Case
DPO2CONN Communication I/O Module: Ethernet and External Monitor Out
EDUKIT Educators Resource Kit
HCTEK4321 Hard Carrying Case
RMD2000 Rackmount Kit
TPA-BNC Probe adapter from TekProbe-BNC to TekVPI
Data SheetModuleDescriptionConfigure and Quote
DPO2CONN Communication I/O Module: Ethernet and External Monitor Out Configure & Quote
TitleTypeDate
Tkdpo2k3k4k_ReadWaveform() Function in the IVI-C Driver Keeps Timing Out
The Tkdpo2k3k4k_ReadWaveform() function makes use of the Service Request Event in VISA so the scope can notify the driver when it has completed its acquisition and the waveform data is ready to be fetched as opposed to the driver polling the scope for…
FAQ ID: 72221 19 Sep 2016
RC4 Wireless Lights It Up with Tektronix MSO2000 Series
James Smith at RC4 develops custom wireless dimming and control products, for high-profile clients like Cirque du Soleil and Disney. Find out how James used the MSO2024 to shave hours off troubleshooting, and what impressed James so much that he "took a…
Literature number: 3GW-24465-0
Case Study 01 Feb 2016
Smiths Detection Relies on Tektronix to Take the Trouble out of Troubleshooting
A team of engineers at Smith Detection needed to quickly, efficiently and accurately identify and resolve problems during the development of complex handheld devices. Learn how Smith Detection engineers used Tektronix bench instruments to identify a bus…
Literature number: 48W-24397-0
Technical Brief 01 Feb 2016
How do I save and load a reference waveform to a DPO/MSO3000 series oscilloscope?
This Video will explain how to setup, save and load a reference waveform. It can be done through a USB flash drive or by internal memory.This method for using reference waveforms can be applied to all MSO/DPO2000, MSO/DPO3000, MSO/DPO/MDO4000 series…
FAQ ID: 64641 15 Dec 2015
How do I utilize the XY display feature on a DPO/MSO/MDO4000 Series oscilloscope?
The XY display format can be used to measure the phase relationship between two or more synchronous signals. This measurement technique involves inputting one signal into the vertical system as usual and then another signal into the horizontal system –…
FAQ ID: 64666 15 Dec 2015
What are some of the benefits of the TekVPI probe interface?
The biggest benefits of the TekVPI™ probe interface are versatility and ease of use.Oscilloscopes with TekVPI interface support a wide range of probes including TekVPI probes, BNC and TekProbe-BNC Level 1 probes, and TekProbe-BNC Level 2 probes (via a TPA…
FAQ ID: 56016 15 Dec 2015
Companies such as National Instruments and LeCroy sell USB-to-GPIB adapters. How do their adapters compare to the TEK-USB-488?
The products from National Instruments (GPIB-USB-B or GPIB-USB-HS) and LeCroy (WS-GPIB) are USB host to GPIB device adapter. These would be used for instruments that have a GPIB interface with controllers that have a USB port. The TEK-USB-488 was designed…
FAQ ID: 56456 14 Dec 2015
The data sheet for my oscilloscope says that the vertical input sensitivity is 1 mV/div to 10 V/div in 1 MΩ mode. But I turn the Vertical Scale control fully clockwise and I can only get down to 10 mV/div. What am I doing wrong?
You probably aren't doing anything wrong. But you do have a 10X probe attached to that channel, right?The 1 mV/div specs relate to the oscilloscope inputs. If the signal’s source impedance is relatively low (<< 1 MOhm), the signal’s frequency is…
FAQ ID: 58571 14 Dec 2015
Is there a mictor adapter for the P6616 (logic probe for MSO5000B, MSO4000B, and MDO4000C + MDO4MSO) or P6516 (logic probe for the MSO4000 Series) or the P6316 (logic probe for MSO2000, MSO3000, MDO3000 + MDO3MSO Series)?
A mictor adapter is available from our partner Nexus Technologies. Use the mictor adapter NEX-HD2HEADER http://www.nexustechnology.com/products/laAccessories/hd2header/  
FAQ ID: 59716 11 Dec 2015
Why Should My Signal Fit Within The Screen Of My Tektronix Oscilloscope?
Scaling your signal to fit within the screen will remove signal distortion caused by clipping. Clipping is caused by exceeding the limits of the instrument's input. Tektronix's digital oscilloscopes are designed such that each division is 25 digital…
FAQ ID: 60306 11 Dec 2015