5 Series MSO Mixed Signal Oscilloscope

5 Series MSO Mixed Signal Oscilloscope

With a remarkably innovative pinch-swipe-zoom touchscreen user interface, the industry's largest high-definition display, and 4, 6, or 8 FlexChannel™ inputs that let you measure one analog or eight digital signals, the 5 Series MSO is ready for today’s toughest challenges, and tomorrow’s too. It sets a new standard for performance, analysis, and overall user experience.

Bandwidth

Up to 2 GHz

Record length

Up to 125 Mpoints

Analog channels

4 or 6 or 8

Digital Channels

Up to 64

More than just a new display and user interface. A new standard.

Get the big picture and take total control, with the 15.6 HD touchcreen display. Use the capacitive pinch-zoom-swipe touchscreen, front panel controls, or mouse to analyze and manage multiple signals without fighting through menus.

Don't run out of channels.

Available with 4, 6, or 8 FlexChannel inputs. Each can be used to look at 1 high-resolution analog waveform or look at 8 digital logic waveforms, just by changing the probe.

Let no detail go unseen, with up to 16 bits of vertical resolution.

Small-detail-on-I2C-Clock-Signal

12-bit analog to digital converters deliver up to 16 bits of vertical resolution using advanced digital signal processing. See and measure small signal details, even if they're riding on large signals.

Buy what you need now. Add on as your needs change.

Elemental-MSO58-007

Performance

  • Bandwidth up to 2 GHz
  • Record Length up to 125 Mpoints

Digital Inputs

  • TLP058 Logic Probes each provide 8 digital channels

Operating System

  • Add Windows OS to run PC software on the scope

Signal Generation

  • Add a built-in Arbitrary/Function Generator

Advanced Analysis

  • Serial Decode/Trigger support for key buses like I2C, SPI, USB 2, Ethernet, CAN, LIN, many others
  • Automated compliance testing for Automotive Ethernet
  • Advanced Jitter Analysis
  • Automated Power Measurement and Analysis

What's in the box?

8-channel MSO58 model shown
  • 1 passive probe per input channel:
    • TPP0500B (500 MHz) when you choose either the 350 or 500 MHz bandwidth option
    • TPP1000 (1 GHz) when you choose either the 1 or 2 GHz bandwidth option
  • 1-year warranty on the included probes
  • 3-year warranty on the instrument
  • Mouse, power cord and front cover with attached accessory pouch
  • Printed Installation Manual covers safety and basic operation
  • Comprehensive Integrated Online Help
  • Certificate of traceability

Models

Model Analog Bandwidth Sample Rate Record Length Analog Channels Digital Channels Function Generator Output List Price
MSO54 350 MHz - 2 GHz 6.25 GS/s 62.5 Mpoints - 125 Mpoints 4 Up to 32 (optional)

1 (optional)

US $13,000
Configure & Quote
MSO56 350 MHz - 2 GHz 6.25 GS/s 62.5 Mpoints - 125 Mpoints 6 Up to 48 (optional)

1 (optional)

US $16,200
Configure & Quote
MSO58 350 MHz - 2 GHz 6.25 GS/s 62.5 Mpoints - 125 Mpoints 8 Up to 64 (optional)

1 (optional)

US $21,800
Configure & Quote
ModelMSO54
List PriceUS $13,000
Analog BandwidthSample RateRecord Length
350 MHz - 2 GHz6.25 GS/s62.5 Mpoints - 125 Mpoints
Analog ChannelsDigital ChannelsFunction Generator Output
4Up to 32 (optional)

1 (optional)

ModelMSO56
List PriceUS $16,200
Analog BandwidthSample RateRecord Length
350 MHz - 2 GHz6.25 GS/s62.5 Mpoints - 125 Mpoints
Analog ChannelsDigital ChannelsFunction Generator Output
6Up to 48 (optional)

1 (optional)

ModelMSO58
List PriceUS $21,800
Analog BandwidthSample RateRecord Length
350 MHz - 2 GHz6.25 GS/s62.5 Mpoints - 125 Mpoints
Analog ChannelsDigital ChannelsFunction Generator Output
8Up to 64 (optional)

1 (optional)

Model Analog Bandwidth Sample Rate Record Length Analog Channels Digital Channels Function Generator Output List Price
MSO54 350 MHz - 2 GHz 6.25 GS/s 62.5 Mpoints - 125 Mpoints 4 Up to 32 (optional)

1 (optional)

US $13,000
Configure & Quote
MSO56 350 MHz - 2 GHz 6.25 GS/s 62.5 Mpoints - 125 Mpoints 6 Up to 48 (optional)

1 (optional)

US $16,200
Configure & Quote
MSO58 350 MHz - 2 GHz 6.25 GS/s 62.5 Mpoints - 125 Mpoints 8 Up to 64 (optional)

1 (optional)

US $21,800
Configure & Quote
ModelMSO54
List PriceUS $13,000
Analog BandwidthSample RateRecord Length
350 MHz - 2 GHz6.25 GS/s62.5 Mpoints - 125 Mpoints
Analog ChannelsDigital ChannelsFunction Generator Output
4Up to 32 (optional)

1 (optional)

ModelMSO56
List PriceUS $16,200
Analog BandwidthSample RateRecord Length
350 MHz - 2 GHz6.25 GS/s62.5 Mpoints - 125 Mpoints
Analog ChannelsDigital ChannelsFunction Generator Output
6Up to 48 (optional)

1 (optional)

ModelMSO58
List PriceUS $21,800
Analog BandwidthSample RateRecord Length
350 MHz - 2 GHz6.25 GS/s62.5 Mpoints - 125 Mpoints
Analog ChannelsDigital ChannelsFunction Generator Output
8Up to 64 (optional)

1 (optional)

  Tektronix
5 Series MSO
Tektronix
MSO/DPO5000B
Keysight
S-Series
LeCroy
HDO6000A/HDO8000A
Rohde & Schwarz
RTO2000
Yokogawa
DLM4000 Series
Detailed Comparison -- -- Fact Sheet Fact Sheet Fact Sheet Fact Sheet
Bandwidth 350 MHz to 2 GHz 350 MHz to 2 GHz 500 MHz to 8 GHz 350 MHz to 1 GHz 600 MHz to 6 GHz 350 MHz, 500 MHz
Upgradeable Bandwidth Yes No Yes No Yes No
Analog Channels 4, 6, or 8 4 2 or 4 4 or 8 2 or 4 8
Analog Sample Rate (All Channels) Up to 6.25 GS/s Up to 5 GS/s Up to 10 GS/s Up to 2.5 GS/s Up to 10 GS/s 2.5 GS/s
Standard Record Length (All Channels) 62.5 M 25 M 50 M 50 M 50 M 25 M
Integrated Arbitrary/Function Generator 50 MHz (opt.) -- -- -- 100 MHz (opt.) --
Digital Channels (MSO) Up to 64 (opt.) 16 (opt.) 16 (opt.) 16 (opt.) 16 (opt.) 8 (std) / 24 (opt)
ADC Resolution 12-bits 8-bits 10-bits 12-bits 8-bits 8-bits
Waveform Capture Rate >500,000 wfms/sec 250,000 wfms/sec <1,100 wfms/sec <700 wfms/sec 1,000,000 wfms/sec N/A
Operating System Closed Linux
Open Windows (opt.)
Open Windows Open Windows Open Windows Open Windows Closed
Standard Probes Up to 1 GHz Passive
< 3.9 pF Loading
Up to 1 GHz Passive
< 3.9 pF Loading
500 MHz Passive
9.5 pF loading
500 MHz Passive
10 pF loading
500 MHz Passive
10 pF loading
500 MHz
10.5 pF loading
Standard Warranty 3 years 1 year 3 years 3 years 3 years ?

Embedded Serial Bus Analysis

5series-mixed-signal-oscilloscope-serial-bus.jpg

Automatic serial bus decoding saves time and eliminates errors versus hand decoding. Serial bus triggering and search enable you to isolate events for system-level troubleshooting.

Highlights

  • I2C, SPI
  • USB 2.0
  • Ethernet
  • CAN, CAN FD, LIN, FlexRay
  • SENT
  • I2S/LJ/RJ/TDM
  • ARINC 429, MIL-STD-1553

Automotive Serial Bus Analysis

car-mso5-1

Car designers rely on serial buses for error-free communications between ECUs, sensors and actuators. They can also rely on the 5 Series MSO, equipped with CAN, CAN FD, LIN, FlexRay, and SENT decoding and triggering to be able to get a synchronized view of their systems. The automated Automotive Ethernet compliance suite lets you test to the standard, without becoming high speed bus expert.

Jitter Analysis

5series-mixed-signal-oscilloscope-jitter.jpg

Clocks are the heart of every embedded system and digital communication link. Jitter and other clock distortion can impact system operation, and getting to the root cause can be challenging without the right analysis tools.

Highlights

  • Standard phase noise, TIE, and frequency plots and histograms
  • Optional advanced analysis with jitter decomposition and clock recovery

Power Electronics

5-Series-MSO_Elemental_Shot_6_116

Make reliable, repeatable power quality, harmonics, switching loss, safe operating area measurements and more with the automated power measurement and analysis package. With up to 8 high-resolution channels and a wide range of available probes, the 5 Series MSO is also ideal for evaluating power supply sequencing, and digging into 3-phase power converters.

Highlights

  • Power quality and harmonics
  • Switching loss and safe operating area
  • In-circuit inductor and transformer analysis
  • Multi-output efficiency

Access Digital Channels

Upgrade Description Purchasing Details
TLP058 Logic Probe Each probe accesses 8 digital channels on any FlexChannel for any 5 Series MSO Request a quote on this probe

Add Instrument Functions

Upgrade Description Purchasing Details
SUP5-AFG Add arbitrary function generator Request trial license

Request a quote
SUP5-DVM Add digital voltmeter / trigger frequency counter Software upgrade license file provided upon registration.
Register now.
SUP5-RL-125M Extend record length to 125 Mpts / channel Request trial license

Request a quote
SUP5-WIN Add removable solid state drive with Windows 10 license installed. No trial available

Request a quote

Add Protocol Analysis

Upgrade Description Purchasing Details
SUP5-SRAERO Aerospace serial triggering and analysis (MIL-STD-1553, ARINC429) Request trial license

Request a quote
SUP5-SRAUDIO Audio serial triggering and analysis (I2S, LJ, RJ, TDM) Request trial license

Request a quote
SUP5-SRAUTO Automotive serial triggering and analysis (CAN, CAN FD, LIN, FlexRay) Request trial license

Request a quote
SUP5-SRAUTOSEN Automotive sensor serial triggering and analysis (SENT) Request trial license

Request a quote
SUP5-SRCOMP Computer serial  triggering and analysis (RS-232/422/485/UART) Request trial license

Request a quote
SUP5-SREMBD Embedded serial triggering and analysis (I2C, SPI) Request trial license

Request a quote
SUP5-SRENET Ethernet serial triggering and analysis (10Base-T, 100Base-TX) Request trial license

Request a quote
SUP5-SRUSB2 USB 2.0 serial bus triggering and analysis (LS, FS, HS) (≥ 1 GHz model recommended for HS) Request trial license

Request a quote

Add Serial Compliance Testing

Upgrade Description Purchasing Details
SUP5-CMAUTOEN Automotive Ethernet (100Base-T1 and 1000BASE-T1) automated compliance test solution Request trial license

Request a quote
SUP5-CMUSB2 USB 2.0 automated pre-compliance test solution Request trial license

Request a quote

Add Advanced Analysis

Upgrade Description Purchasing Details
SUP5-DJA Advanced jitter and eye analysis Request trial license

Request a quote
SUP5-PWR Power analysis Request trial license

Request a quote

Upgrade Bandwidth

Upgrade Description Purchasing Details
SUP5-BWxTy8 MSO58 bandwidth upgrade from x to y, where x and y are the hundreds of MHz
  • Up to 1 GHz upgrades can be performed in the field.
  • 2 GHz upgrade requires installation at a Tektronix Service Center via option IFC or IFCIN.
  • Bandwidth upgrades from 350 or 500 MHz, to 1 or 2 GHz also include one TPP1000 1 GHz passive probe per channel.
SUP5-BWxTy6 MSO56 bandwidth upgrade from x to y, where x and y are the hundreds of MHz
SUP5-BWxTy4 MSO54 bandwidth upgrade from x to y, where x and y are the hundreds of MHz
Low Voltage Single Ended Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TAP1500 Active Probe: 1.5 GHz, 10X, Single-ended, TekVPI Configure & Quote
TAP2500 Active Probe: 2.5 GHz, 10X, Single-ended, TekVPI Configure & Quote
Current Probe
Datasheet LinkProbeDescriptionConfigure and Quote
TCP0020 Probe, AC/DC Current; 20 Amp; 50 MHz BW; TekVPI Interface; Certificate of Traceable Calibration Standard Configure & Quote
TCP0030A

Probe, AC/DC Current; 30 Amp DC, DC TO 120 MHZ; with TekVPI Interface; Certificate of Traceable Calibration Standard

Configure & Quote
TCP0150 Current Probe: 20 MHz, 5 mA to 212 A, AC/DC, TekVPI Configure & Quote
High Voltage Differential Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TDP0500 Differential Probe: 500 MHz, 5X/50X, +/- 42V, TekVPI Configure & Quote
TDP1000 Differential Probe: 1 GHz, 5X/50X, +/- 42V, TekVPI Configure & Quote
THDP0100

Differential PROBE; 100 MHZ TekVPI DIFFERENTIAL HIGH VOLTAGE PROBE

Configure & Quote
THDP0200

Differential PROBE; 200 MHZ TekVPI DIFFERENTIAL HIGH VOLTAGE PROBE

Configure & Quote
TMDP0200

Differential PROBE; 200 MHZ TekVPI DIFFERENTIAL MEDIUM VOLTAGE PROBE;TMPD0200

Configure & Quote
Low Voltage Differential Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TDP1500 Differential Probe: 1.5 GHz, 1X/10X, +/-8.5V, TekVPI Configure & Quote
TDP3500

Differential Probe: 3.5 GHz, 5X, +/- 2V, TekVPI

Configure & Quote
Isolated Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TIVH02

Differential Probe; 200 MHZ, 50X/500X, TekVPI, 3 Meter Cable

Configure & Quote
TIVH02L Differential Probe; 200 MHZ, 50X/500X, TekVPI, 10 Meter Cable Configure & Quote
TIVH05

Differential Probe; 500 MHZ, 50X/500X, TekVPI, 3 Meter Cable

Configure & Quote
TIVH05L

Differential Probe; 500 MHZ, 50X/500X, TekVPI, 10 Meter Cable

Configure & Quote
TIVH08

Differential Probe; 800 MHZ, 50X/500X, TekVPI, 3 Meter Cable

Configure & Quote
TIVH08L

Differential Probe; 800 MHZ, 50X/500X, TekVPI, 10 Meter Cable

Configure & Quote
TIVM1 Differential Probe; 1 GHZ, 5X/50X, TekVPI, 3 Meter Cable Configure & Quote
TIVM1L Differential Probe; 1 GHZ, 5X/50X, TekVPI, 10 Meter Cable Configure & Quote
Logic Analyzer Probe
Datasheet LinkProbeDescriptionConfigure and Quote
TLP058

8 channel general purpose logic probe for 5 Series oscilloscopes. Includes accessory kit.

Configure & Quote
Passive Probe
Datasheet LinkProbeDescriptionConfigure and Quote
TPP0500B

Passive Probe: 500 MHz, 10X, TekVPI

Configure & Quote
TPP0502

Passive Probe: 500 MHz, 2X, TekVPI

Configure & Quote
TPP1000

Passive Probe: 1 GHz, 10X, TekVPI

Configure & Quote
High Voltage Single Ended Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TPP0850

High Voltage Probe: 800 MHz, 50X, 2.5 kV, Single-ended, TekVPI

Configure & Quote
Data SheetAccessoryDescription
HC5 Hard transit case for the 5 Series MSO
RM5 Rackmount kit for the 5 Series MSO
TitleTypeDate
5 Series MSO User Interface Differences
When you purchase a 5 Series MSO with the 5-WIN option installed, or upgrade your 5 Series MSO with the SUP5-WIN upgrade, you will see very few differences in the user interface. However, you may notice a few minor differences with Windows, including:…
FAQ ID: 235441 01 Dec 2017
5 Series MSO Roll Mode
Roll Mode provides an instant display response when the oscilloscope is operating at very slow sweep speeds. Without it, the acquisition must complete before the display will update. With Horizontal Scale factors as slow as 1000 s/div, that can be a long…
FAQ ID: 235436 01 Dec 2017
5 Series MSO Bandwidth Upgrades
Bandwidth upgrades to 500 MHz and 1 GHz can be accomplished by ordering an upgrade product and entering a new software license into the instrument. The instrument bandwidth appears in the Help-> About menu near the top of the window, between the Model…
FAQ ID: 235431 01 Dec 2017
5 Series MSO Free Trials
Most field upgrades for the optional features for the 5 Series MSO are also available for a one-time, 30-day free trial. These are available simply by requesting a trial software license and installing the node-locked license in the instrument. There are…
FAQ ID: 235426 01 Dec 2017
5 Series MSO Feature Upgrades
Most optional, factory-installed features for the 5 Series MSO are also available as field upgrades, and are installed simply by ordering an upgrade product and entering a new, node-locked software license into the instrument. There are several general-…
FAQ ID: 235421 01 Dec 2017
5 Series MSO Setup File Recall Warning
The 5 Series MSO will display a pop-up warning message when it is not completely successful recalling the saved state of the instrument with a setup or session file. The following message will appear on the display: WARNING The oscilloscope was unable…
FAQ ID: 235416 01 Dec 2017
5 Series-Mixed Signal Oscilloscopes
This document how to install optional upgrade licenses to add new functions or features to the 5 Series Mixed Signal Oscilloscopes (MSO54, MSO56, MSO58).
Part number: 071351900
Field Install Instructions 10 Oct 2017
Tools to Boost Oscilloscope Measurement Resolution to More than 11 Bits
Measurement resolution depends on more than the number of bits coming out of an oscilloscope's ADC. You need to have a whole-system, end-to-end approach to limit the effects of noise, as well as improve resolution. Learn measurement and signal-processing…
Literature number: 48W-27802-4
Application Note 10 Oct 2017
Keysight X6000 Series vs. 5 Series MSO Mixed Signal Oscilloscope Comparison
This fact sheet compares important specifications and features of the Tektronix 5 Series MSO Mixed Signal Oscilloscope to those of the Keysight X6000 Series
Literature number: 65W-61109-0
Competitive 10 Oct 2017
Probing Techniques for Accurate Voltage Measurements on Power Supplies with Oscilloscopes
This application note explains probing techniques for making high-quality measurements on power supplies. It covers the use of passive and differential probes with emphasis on applications in power conversion circuits.
Literature number: 51W-60161-2
Application Note 10 Oct 2017
Downloads
Download

Download Manuals, Datasheets, Software and more: