Do you have a CAL signal that drives all the channels in parallel+ so that I can verify that the probes are working correctly?Yes, use the probe calibration adapter which is a standard accessory.
This FAQ applies to:
TLA7E2, TLA7D1
60546
Can I skip quantizing in the DSO and use the data in the LA instead?Yes, there is a Magnitude Mode display in the Waveform window that provides a digital-to-analog display of a given channel group. The primary application are for users who want to display the actual value of data acquired from a bus, e.g., data encoded in a video signal.
This FAQ applies to:
TLA7E2, TLA7D1
60446
Can I load any Windows®-compatible software on the oscilloscope?
You have unrestricted access to the Windows desktop and can load Windows-compatible software on the instrument.
This FAQ applies to:
TDS7054
60441
Are there voltage cursors for the DSO?Yes, to an extent. When a cursor is positioned on a selected analog waveform, you get a readout of both time and voltage; however, at the position of the vertical cursor there are not unique horizontal voltage cursors.
This FAQ applies to:
TLA7E2, TLA7D1
60391
Are the TDS7000 Series Oscilloscopes DPOs?Yes, the TDS7000 family is our newest family of digital phosphor oscilloscopes.
This FAQ applies to:
TDS7054
60381
Are the applications for the TDS7000 Series still Java-based?
Yes. All of the applications programs were Java based.
This FAQ applies to:
TDS7054
60361
What common data formats are available for the data outputs+ e.g.+ NRZ (non-return-to-zero) or RZ (return to zero)?NRZ only for data channels. Strobes are RZ (leading or trailing edge).
This FAQ applies to:
TLA7PG2
59931
Some of the devices we design use very unique frequencies. Can the timebase of the 7PG2 generate a broad range of frequencies with high resolution?Yes, with 8-digit resolution for the clock period.
This FAQ applies to:
TLA7PG2
59816
On the P6471 ECL probe can it be applied equally well to both negative (ECL) and positive (PECL) voltage supply systems?Positive ECL logic (PECL) is not currently supported.
This FAQ applies to:
TLA7PG2
59776
On some of our devices+ some of the I/O channels are changed from input to output channels on-the-fly. Can the 3-state bit assignments be changed during the test on-the-fly also?The TLA7PG2 does not support on-the-fly channel-to-channel changes.
This FAQ applies to:
TLA7PG2
59766