Download

Download Manuals, Datasheets, Software and more:

DOWNLOAD TYPE
MODEL or KEYWORD

Feedback

2-RK Rackmount Kit Instructions

2-RK instructions for installing the MSO22 and MSO24 rackmount kit

This document supports installing the 2 Series MSO with the rackmount kit in a standard equipment rack.


This manual applies to:

MSO22, MSO24, 2-RK

  • Manual Type: Field Install Instructions
  • Part Number: 071376500
  • Release Date:

By downloading, you agree to the terms and conditions of the Manuals Download Agreement.

Manuals Download Agreement

ATTENTION: please read the following terms and conditions carefully before downloading any documents from this website. By downloading manuals from Tektronix' website, you agree to the following terms and conditions:

Manuals for Products That Are Currently Supported:

Tektronix hereby grants permission and license to owners of Tektronix instruments to download and reproduce the manuals on this website for their own internal or personal use. Manuals for currently supported products may not be reproduced for distribution to others unless specifically authorized in writing by Tektronix, Inc.

A Tektronix manual may have been revised to reflect changes made to the product during its manufacturing life. Thus, different versions of a manual may exist for any given product. Care should be taken to ensure that one obtains the proper manual version for a specific product serial number.

Manuals for Products That Are No Longer Supported:

Tektronix cannot provide manuals for measurement products that are no longer eligible for long term support. Tektronix hereby grants permission and license for others to reproduce and distribute copies of any Tektronix measurement product manual, including user manuals, operator's manuals, service manuals, and the like, that (a) have a Tektronix Part Number and (b) are for a measurement product that is no longer supported by Tektronix.

A Tektronix manual may be revised to reflect changes made to the product during its manufacturing life. Thus, different versions of a manual may exist for any given product. Care should be taken to ensure that one obtains the proper manual version for a specific product serial number.

This permission and license does not apply to any manual or other publication that is still available from Tektronix, or to any manual or other publication for a video production product or a color printer product.

Disclaimer:

Tektronix does not warrant the accuracy or completeness of the information, text, graphics, schematics, parts lists, or other material contained within any measurement product manual or other publication that is not supplied by Tektronix or that is produced or distributed in accordance with the permission and license set forth above.

Tektronix may make changes to the content of this website or to its products at any time without notice.

Limitation of Liability:

TEKTRONIX SHALL NOT BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION, OR FOR INFRINGEMENT OF INTELLECTUAL PROPERTY) ARISING OUT OF THE USE OF ANY MEASUREMENT PRODUCT MANUAL OR OTHER PUBLICATION PRODUCED OR DISTRIBUTED IN ACCORDANCE WITH THE PERMISSION AND LICENSE SET FORTH ABOVE.

 

Read Online

Kit description

The 2-RK rackmount kit is a collection of parts that, once installed, configure the instrument for mounting into a standard 19-inch equipment rack.

This kit supports all 2 Series MSO instruments.

Parts list

ItemPart NumberQuantityDescription
1407-6248-XX1Rackmount bracket
2211-1732-XX8Screw, M4X.7X8mm. Use for attaching the bracket to the instrument.
3212-0577-XX4Screw, Machine 10-32x.625. Optional, use for attaching the instrument with bracket to the rack.

Recommended installation tools

Use a screwdriver handle with No. 2 Phillips screw tip or a No. 2 Phillips screwdriver to install your rackmount kit.

Warranted characteristics

When the instrument is installed according to the instructions in this document, the rackmounted instrument meets all warranted requirements listed in the instrument specification. Instruments mounted using methods other than those described in these instructions might not meet their warranted requirements.

For tables of the warranted characteristics, see Specifications in the specification and performance verification manual that applies to your instrument model.

CAUTION:The rack is more susceptible to tipping when the instrument is installed. To prevent the rack from tipping, ensure that the rack is stable before accessing rear panel of the instrument.

The ambient temperature inside the instrument rack will vary depending on the location of the instrument within the instrument rack. Tektronix recommends that you measure the ambient temperature in the desired rack location before you install the instrument to ensure the operating temperature does not exceed the rated ambient temperature limit. If necessary, refer to the Environmental Specifications in your product documentation for the operating temperature limits.

CAUTION:The instrument might be damaged due to overheating. When installing multiple instruments in an instrument rack, the ambient temperature may go up. You assume the responsibility to provide adequate cooling to meet the ambient temperature requirements listed in the specifications.

Clearance requirements

The rack in which the individual instrument is mounted must provide the following clearance requirements.

  • At least 222 mm (8.75 in) of vertical space or 5 RU (rack units) of vertical space.
  • A minimum inside depth of at least 14 mm (0.55 in) depth (from rack mounting ear to back of instrument).
  • A minimum external clearance of at least 34 mm (1.34 in) frontwards from rack mounting ear.
  • Airflow enters from underneath the instrument and exits at the top of the instrument. The rack mount bracket ensures clearance for adequate airflow.
  • No additional clearance is needed on the left or right sides of the instrument for adequate airflow.
CAUTION:Adhering to these requirements mounts the rack-adapted instrument with enough clearance for air circulation and accommodation of the power cord and mounting hardware. Failure to provide these clearances can result in overheating and can cause the instrument to operate improperly or fail.

Install the rackmount on the instrument

Install the 2-RK rackmount onto the back of your 2 Series MSO instrument using the following instructions.

Before you begin

These instructions are for qualified service personnel who are familiar with servicing the product. If you need further details for disassembling or reassembling the product, refer to the appropriate product manual. Contact your nearest Tektronix, Inc., Service Center or Tektronix Factory Service for installation assistance.

Procedure



  1. Install two screws to the top VESA mount holes (closest to the top of the label) on the back of the instrument.
    Do not fully tighten the screws.
  2. Slide the rackmount over the top two screws.
  3. Fully install two screws to the bottom VESA mount holes (closest to the bottom of the label) to secure the rackmount to the instrument.
  4. Fully tighten the top two screws from the first step.
  5. Install the remaining four screws to the outer rackmount holes.

Install the instrument into the rack

Install the 2 Series MSO instrument with the rackmount into your rack.

Before you begin

Align the rackmount on the rack to determine the location of the bottom two rackmount screws.

Procedure

  1. Install the bottom two rackmount screws to the rack.
    Do not fully tighten the screws.
  2. Slide the rackmount over the bottom two screws.
  3. Install the top two rackmount screws and fully tighten the bottom two screws.

What to do next

Connect the necessary cables and the power cord.

Dimensions

The dimensions of the rackmount installed on the instrument.

Help us improve our technical documentation. Provide feedback on our TekTalk documentation forum.