Measurement Sets
VM700T Option 01
Features
& Benefits
- Many Capabilities in One Instrument
- Digital
Waveform Monitor
- Digital Vectorscope
- Picture Display
- Group
Delay and Frequency Response
- Noise Measurement Set
- Automatic
Measurement Set
- Measure Mode Provides Graphic Display of Measurements
- ICPM
- K
Factor
- Differential Gain and Phase
- Chrominance to Luminance
Delay
- Noise Spectrum
- Group Delay with Sin x/x
- Color
Bars
- Relative to Reference on Most Measurements
- Configurable
for All Standard Test Signals
- Award-winning User Interface
- Extremely
Fast Update Rate
- Parallel and Serial Printer Ports
- Three
Input Channels
- Channel Difference Modes
- External VGA Display
Port
- Fully Documented Remote Control Operation
- Hardcopy
for Analysis and Documentation
- S-Video Capable
Applications
- Research
and Development
- Quality Assurance and Signal Compliance Testing
- Automated
Functional Test
- Unattended Monitoring of Video Signals from Studios,
STL's, Earth Stations and Transmitters
- Baseband Network Monitoring
NTSC Video
Measurements
Recognized with a technical Emmy award, Tektronix' world
class core competencies have enabled it to design and deliver the most comprehensive
video measurement solutions in the industry.
Recognized as the de facto
industry standard that keeps pace with evolving customer needs, the VM700T
is a total solution for your baseband video and audio monitoring and measurement
needs. Features such as an extremely fast and fully automatic measurement
mode as well as full manual operation provides the first-time user, as well
as the seasoned professional, an unequaled value for their test and measurement
investment.
Automatic Video Measurement Set
The VM700T Auto
mode makes standard video transmitter measurements quickly and automatically,
including those specified in RS-250C/EIA-250C, NTC-7 and RS170A. Both vertical
interval and full field measurements can be made and compared with user-defined
limits. A dual limit verification system is employed to generate a caution
or alarm message when either limit is violated. Reports can be generated and
printed automatically at operator scheduled times or triggered from a conditional
event.
Graphic Displays of Measurements
Measure mode provides
virtual real-time graphic displays of measurement results automatically. Vertical
interval or full field measurements including noise spectrum, group delay,
K-Factor, differential gain and differential phase are presented as clever,
easy to understand interactive digital displays. Such displays are indispensable
when extremely fast measurement update rates (up to 30 times a second) are
required to provide instant feedback of critical adjustments and analysis
of signal variations. User-definable limits are visually integrated into each
graphic display and can be used to trigger a measurement report or a user-definable
macro function. Such a function can, for example, dial out through a modem
to report measurement results or control a signal router. A relative to reference
mode allows normalizing to a signal source or eliminate signal path errors
from the desired measurement. Up to two video references can be stored in
NVRAM. Additionally, after downloading to a PC through the VM700T FTP driver,
the video reference can be uploaded to another VM700T for reuse. A running
averaging mode can be used to reduce the effect of noise. When additional
measurement data is required, a user can custom configure measurement parameters
and report format.
Main
Measure Mode display of available measurements.
Measure Mode DGDP special position
acquisition feature.
A powerful Test Signal search
capability quickly and automatically locates and identifies valid test signals
required for a selected measurement, eliminating the annoying and time consuming
task of manually locating test signals.
Digital Waveform Monitor/Vectorscope
The
VM700T Waveform mode application provides real time graphics displays of the
video signal allowing many additional measurements to be made manually. Easy
to use measurement cursors are available to measure time, frequency and amplitude
parameters of a video signal. These cursors allow a very quick and precise
location of the 10%, 50% and 90% points on any transition. Cursor mode also
employs an automatic calculation in the wave shape in the center of the display.
The parameters calculated are sine peak-to-peak amplitude, frequency and offset
from blanking level. This is very useful for frequency response measurements
with the Multiburst signal.
The waveform display can be expanded around
any point both vertically and horizontally. Since the data is digitized, the
display remains bright and easy to read at all expansion factors. The scales
automatically expand with the waveform, so all units are correct as displayed.
A channel difference mode (A-B, A-C, B-A, B-C, C-A and C-B) is also provided.
A screen memory selection enables Envelope mode, which is useful for looking
at teletext, Jitter or other changes over time.
Vector mode provides
the normal vectorscope display. The vectors may be rotated or expanded, with
the rotation angle and gain values displayed numerically on the screen.
In
Vector Mode, the VM700T becomes a digital vectorscope with an electronic graticule.
A "ColorBar Search" feature makes it easy to quickly display a line containing
a color bar test signal.
Vertical interval test signals
can be seen very clearly for additional analysis of the signal. These can
be printed as support documentation for automatic measurement results.
A
unique "Find ColorBars" feature searches all video for ColorBars and displays
the vectors if found. The vectors can be referenced to either the selected
channel's burst or the burst of one of the other two channels or continuous
subcarrier. The phase difference between the selected channel and the reference
is always displayed.
Select Line in both Waveform and Vector modes
can be used to quickly specify any line for display or automatic measurement
if it is the proper signal.
Picture Mode
The signal source
can be quickly verified using the picture display. Additionally, a "bright-up"
line select mode allows a user to select any video line for use in Measure
mode or for viewing in Waveform or Vector mode.
User Programmable
Functions
Picture
Mode display. (Video courtesy of KOIN-TV, Portland, Oregon.)
Even
a single horizontal synchronization pulse can be displayed at a high intensity.
Function
mode is an extremely powerful feature that allows a user to store a sequence
of user operations as a macro function for later "playback."
For example,
a set of measurements (complete with hardcopy commands) to be made on a transmitter
demodulator video output, could be stored as a function labeled "DEMOD." The
function "playback" could then be initiated manually, remotely or completely
automatically as a user specified timed event. Function files can be stored
as a text file on a PC for editing, copying or uploading to another VM700T.
Other function capabilities include controlling of external serial devices
such as video/audio routers, switchers, signal generators, telephone modems
and many other devices which support RS-232 communications.
Hardcopy
All
information on the screen may be printed in high resolution graphics on printers
supporting PostScript, Hewlett-Packard LaserJet, DeskJet and ThinkJet or 24-Pin
Epson graphics via the Centronics compatible parallel port or standard RS-232C
interface.
Automatic measurement results in text format can be printed
on most ASCII printers using the parallel or serial ports.
Remote
Operation
The VM700T has a powerful and fully documented remote control
language. The VM700T can thus be operated from a remote terminal via RS-232C
to monitor unattended transmission systems. In addition, all files can be
uploaded to a main computer and downloaded to other VM700Ts. Two different
protocols are supported: FTP (File Transfer Protocol) and TELNET. The user
can also select a "no protocol" mode of the RS-232C interface when dealing
with low baud rates. However, file transfers can only take place with FTP.
|