Changeover Unit
ECO422D SD/HD
Features
& Benefits
- Switches Analog Black and Serial Digital Video,
Both Standard and High-Definition, and Digital Audio
- Eleven User-configurable
Signal Channels
- Amplitude Detection on All Channels
- Electrical
Fast Switch Function for Input Channels 4 to 6, with Option ELSW
- Automatic,
or Manual Operation
- Fault and Operating Mode Front Panel Indicators
Applications
- Provides
Complete Fault Tolerance When Used as a Switch Between Primary and Back Up
SPGs or TSGs
The ECO422D is a highly versatile
sync changeover unit designed for use in a serial SD/HD digital television
environment. The ECO422D will accommodate component or composite serial digital
video signals, AES/EBU digital audio, tri-level sync and analog black burst
signals. This flexibility makes the ECO422D ideal for both the mixed-format
and all-digital television facility.
The ECO422D provides eleven user-configured
channels, each channel consisting of primary and backup inputs, and an output.
- Six
channels can be set for high definition serial digital video, standard definition
serial digital video, AES/EBU digital audio, tri-level sync and PAL or NTSC
analog black burst
- Five channels may be set for standard definition
serial digital video, AES/EBU digital audio, tri level sync and PAL or NTSC
analog black burst
Channel configuration is by internal DIP
switch. Signal amplitude fault detection level follows the setting of the
channel configuration switches. Detection on individual channels may be disabled,
giving the option of disabling changes to the backup unit on failure of signals
not critical to the facility operation.
When operated in the switch-on-fault
mode, the ECO422D will automatically select the backup sync source should
any of the primary inputs fail. However, in the unlikely event both sync sources
are faulty, the ECO422D will not alternate between the two sources. If necessary,
this function may be overridden with the manual sync source selection. Manual
source selection also facilitates periodic testing of the changeover function.
Switching is by mechanical relay with all channels switched simultaneously.
The
Electrical Fast Switch function, available with Opt. ELSW, improves the changeover
switching speed between inputs, and replaces the mechanical relay on channels
4-6. Using this type of switch minimizes disturbance when switching between
primary and backup inputs. With Opt. ELSW, channels 4-6 can only accept a
Black Burst or Tri-level sync signal.
Front panel controls are provided
for source selection, operating mode, resetting the fault indicators, and
for disabling the front panel controls. LED indicators are also provided.
Indication of fault and unit on line is also available via the remote connector.
|