DSA8200 Sampling Oscilloscope
Industry Leading Signal Fidelity for the Most Challenging System Designs
Today's high speed designs make signal path characterization and BER performance analysis harder then ever before. With the highest TDR Bandwidth, the fastest S-parameter measurements, and most comprehensive analysis tools available. The DSA8200 digital serial analyzer provides a complete network and link analysis solution.
- Overview
- Application Notes
- Probes & Accessories
- DSA8200 Modules
- Software Packages
Features |
Benefits |
| Up to 4 true differential channels | Accurately characterize non-linear devices such as amplifiers with true differential TDR stimulus. |
| High bandwidth (50 GHz) Time Domain Reflectometry | Resolve impedance discontinuities down to 1mm with a 12 ps incident step. |
| IConnect® signal integrity | Reduce measurement errors resulting from test fixture signal degradation with integrated TDR and S-Parameter measurements. |
| Serial data network analysis (SDNA) | Reduce cost of test by combining time and frequency domain analysis with a single instrument. Accurately analyze signal path to predict signal crosstalk and jitter to ensure reliable system operation. |
| Serial data link analysis (SDLA) | Determine precise causes of eye closure with jitter, noise, and BER analysis.
Maximize the eye opening at the receiver by quickly evaluating various FFE/DFE equalization setups. |
| Remote sampling heads | Optimize signal fidelity and minimize the effects of probes, cables, and fixtures by bringing the TDR head close to the device under test. |
High-speed Interconnects: Characterization and Measurement-based Modeling
A primer that takes on the measurement issues of high-speed interconnects.
TDR and S-parameters Measurements - How Much Performance Do You Need?
How TDR-based measurement tools can provide you a quicker way to making s-parameter measurements over the traditional VNA.
TDR Impedance Measurements: A Foundation for Signal Integrity
At today's high operating frequencies, anything that affects your signal's rise time, pulse width, timing, jitter or noise content can impact reliability at the system level.
The Basics of Serial Data Compliance and Validation Measurements
Understand the common aspects of serial data transmission and analog/digital measurement requirements for emerging serial technologies.
Following is a list of common probes and accessories. Don't see what you need? Visit the Probes & Accessories Advisor to find the right probe for your application.
|
|
| P6150 | 9 GHz Passive Probe; the probe consists of a very high quality 20 GHz probe tips, plus an extremely flexible SMA cable. For higher frequency performance the 015-0560-00, or some of the accessory cables listed can be used. |
| P8018 | 20 GHz Single-Ended TDR Probe. 80A02 module recommended for static protection of the sampling or TDR module. |
| P80318 | 18 GHz 100 Ω Differential Impedance TDR Hand Probe. |
| 80A03 | Enables the use of two Tektronix P7000 Series TekConnect™ probes on the DSA8200 or 8000 Series sampling oscilloscopes. |
| P7513 / P7516 | 13 GHz and 16 GHz TriMode™ Differential probes. Requires 80A03 interface module. |
| P7260 | 6 GHz Active FET Probe. Requires 80A03 interface module |
| P7350 | 5 GHz Active FET Probe. Requires 80A03 interface module |
| P7350SMA | 5 GHz 50 O Differential-to-Single ended Active Probe. Requires 80A03 interface module. Note that the P7380 probes are recommended over the P7350 probes for sampling purposes due to their higher bandwidth and signal fidelity. |
| P7380SMA | 8 GHz 50 O Differential-to-Single ended Active Probe. Requires 80A03 interface module. |
| 80A01 | Pre-scaled Trigger Amplifier. Not required on the DSA8200, CSA8200, or TDS8200 mainframes with their increased sensitivity pre-scalar. The Amplifier enhances pre-scalar sensitivity on the older TDS8000B and CSA8000B mainframes. |
| 80A02 | DSA8200 EOS/ESD Protection Module (1 channel). P8018 TDR probe recommended. |
| 82A04 | Phase Reference Module for low jitter acquisition (with or without trigger). Accepts signals from 2 GHz to 25 GHz (external filter might be required below 8 GHz), or to 60 GHz with Option 60G. |
| 80A05 | Electrical clock recovery module/clock recovery. Applicable to electrical signals and for the 80C12. |
| 80A06 | PatternSync module for 80SJNB jitter analysis package. Programmable divider for creating a trigger pulse from patterns up to 223 in length. |
| 80E04 | SAMPLING MODULE; DUAL,20 GHZ W/TDR ELECTRICAL SAMPLING MODULE |
| 80E08 | REMOTE SAMPLING MODULE; DUAL CHANNEL, 30 GHZ ELECTRICAL WITH TRUE DIFFERENTIAL TDR |
| 80E10 | REMOTE SAMPLING MODULE; DUAL CHANNEL, 50 GHZ ELECTRICAL WITH TRUE DIFFERENTIAL TDR |
| 80C07B | OPTICAL SAMPLING MODULE; 2.488 GB/S OC48/STM16,2.500 GB/S 2GBE,2.500 GB/S INFINIBAND;2.5 GHZ OPTICAL BANDWIDTH |
| 80C08C | OPTICAL SAMPLING MODULE; 9.953/10.31 GB/S 10 GBE,10.51875 GB/S 10GFC,10.664 GB/S G.975,10.71 GB/S G.709,11.1 GB/S 10 GBE FEC;10 GHZ OPTICAL BANDWITH |
| 80C10B | OPTICAL MODULE; 39.813/43.018 GBPS/80 GHZ |
| 80C12 | Broad wavelength (700 to 1650 nm) multi-rate optical sampling module providing 1G, 2G, 4G, and 8G telecom and datacom testing |
| IConnect® MeasureXtractor™ | Signal Integrity TDR and S-parameter Analysis Software. | Check List Price |
| 80SJNB | Jitter, Noise and BER Analysis Software. | Check List Price |