I need to capture waveform data as fast as possible. How many waveforms per second can I transfer over the bus? How many can I store in internal memory?
Bus transfer rate. A number of factors control how many waveforms per second can be stored. You must use a specific bus command, and make sure that the instrument is transferring binary data that comes out MSB. Under those conditions the instrument...
This FAQ applies to:
DSA601A, DSA602A
837024
How do I order the mating connectors for the audio output connectors on the newer DS1001A/G?
A set or three mating connectors is available from Tektronix as part number 020-2381-00
This FAQ applies to:
DS1001A, DS1001G
836633
How does the VM700T make Chrominance AM/PM Noise Measurements?
The attached document gives an in-depth overview of the basics of Chrominance AM/PM Noise and how this is measured with the VM700T.
This FAQ applies to:
VM700A, VM700T
837280
How does the VM700T make Intermodulation Distortion (IMD) Measurements?
The attached document gives an in-depth overview of the basics of Intermodulation Distortion and how this is measured with the VM700T.
This FAQ applies to:
VM700A, VM700T
837281
What are the Hydra In+ Hydra Out+ TekLink and Ethernet connectors on the PG3ACAB and PG3AMOD used for?
Currently these connectors are non-functional.  Teklink and Ethernet may be added in the future. The Hydra connectors are for linking multiple modules in parallel to function like one very-wide pattern generator. Again, this capability is not...
837520
What do the curved lines on the vectorscope display of color bars mean?
When a color bar signal is displayed on a vectorscope the ends of the vectors are positioned in the boxes marked Red, Magenta, Blue, Cyan, Green, and Yellow. The trace lines connecting the boxes should be straight. When the lines are curved it...
This FAQ applies to:
WVR500, WFM91D, 1740A, 1750A, 1760, WFM90D, 1720, WVR610A, WVR7100
836817
7000 SERIES OSCILLOSCOPES FAQ
The 7000 Series oscilloscopes were produced from about 1970 to 1995. While there were various mainframes, the 7000 Series plug-ins worked interchangeably with most all of the mainframes. The breadth of plug-ins available became the strength of the...
836818
: The RTSA spectrogram displays the time values and these values can be changed. Can the MDO do this?
Not at this time.  Displaying the time values has been added to our list of recommended product enhancements.
This FAQ applies to:
MDO4054-3, MDO4054-6, MDO4104-3, MDO4104-6
876171
<p>I have a problem with reading the measurements from the TDS7404B Oscilloscope. I do not get the measurement (for example Amplitude) for the current waveform when I request the value via IVI-COM. The value I get is either from the previous acquisitio
Rather than relying on Acquisition:State which only tells you when the trigger has occurred, you should instead use one of the steps referred to in the programmers manual in the section titled, "synchronization methods". Most commonly, the *OPC...
This FAQ applies to:
TDS7054, TDS7104, TDS7154
837025
<p>Only the "Administrator-login" works.</p> <p>It is NOT possible to login correctly as another user. You always get the three error-messages described below.</p> <p>I joined our domain and tried to login using the new account and the messages that fo
1) Make sure you are the administrator: Using explorer, open c:\documents and settings\default user folder. 2) On the menu bar, click Tools-> folder options-> view-> click show hidden files and folders. 3) Uncheck hide file extensions for...
This FAQ applies to:
TDS5052, TDS5034, TDS5032
837026

Search by Keyword

Select Service

X

STAY INFORMED: Events & Seminars | Email Newsletter | Follow Tektronix on Twitter Follow Tektronix on Facebook Follow Tektronix on Google+ Follow Tektronix on Youtube

MEMBERSHIP: Create an account for exclusive membership privileges. Learn More | Login