Features & Benefits
- Provides Instrument Control
for the DPO/DSA70000, MSO70000, DPO7000, MSO/DPO5000, MDO4000, MSO/DPO4000,
MSO/DPO3000, MSO/DPO2000, TDS3000, TDS2000, TPS2000, and TDS1000 Series
Oscilloscopes, AFG3000 Series Arbitrary/Function Generators, DMM4000
Series Multimeters, PWS4000 Series Power Supplies, and FCA/MCA3000
Series Timer/Counters
- Quickly Start Measuring with an Intuitive
Drag-and-Drop Interface that Does Not Require Any Programming
- Measurement Trending
- Data Logging
- Advanced
Analysis and Documentation Capabilities
- Quickly and Easily
Import Simulated Results and Compare Against Actual Measured Results
Live on the Screen
- Automatic Frequency Sweeping
- Limit Testing
- Connect and Control Multiple Instruments from
within One Software Environment
Increase
Your Productivity with the Industry’s Most Seamless Instrument-to-PC
Connectivity Solution
Configuring test instruments to connect
with PC-based software is often a difficult and frustrating challenge.
That's why Tektronix and National Instruments have partnered together
to create the Tektronix Edition of National Instruments LabVIEW SignalExpress™
– interactive measurement and analysis software designed for design
and test engineers who need to quickly acquire, analyze, and document
measurements without the added complication of programming.
USB Plug-and-Play
Industry's first true
USB plug-and-play connectivity for oscilloscopes and bench instruments.
With USB plug-and-play support, NI LabVIEW SignalExpress
TE immediately detects and configures Tektronix instruments when connected
to a PC*1, providing a live view of the data acquisition
and immediate control of the instrument.
Import and Compare
Integrate measurements with simulated results from popular design
software tools such as PSpice, SPICE, and Multisim. This enables quick
and easy importing and comparing of simulated results – saving time
and improving design accuracy.
Capture and Document
Quickly capture and document measurements by simply dragging and
dropping acquired data and waveform captures directly into Microsoft
Excel, Word, Outlook, PowerPoint, and WordPad. Or annotate waveforms
and measurements in the interactive project documentation tool.
Advanced Analysis
NI LabVIEW SignalExpress TE contains
more than 200 different measurement, processing, analysis, and reporting
capabilities that can be applied to data being acquired from Tektronix
instruments.
Measurement Trending - Automated measurements
from the oscilloscope or multimeter are graphed over time to provide
a simple indication of trends in the measurement parameters.
Data Logging - Waveform data and measurements can be automatically
logged to the PC’s disk drive for unattended and long-term monitoring
applications.
Automated Measurements
Take advantage
of several major time-saving features, including automated measurement
sweeping and limit testing. These features provide relief from a traditionally
manual and time-intensive process.
Connect and Control
Remove the guesswork when connecting the test instrument to a
PC by connecting and controlling multiple instruments from one software
environment, all within a single drag-and-drop user interface.
SIGEXPTE
The LE version of NI LabVIEW SignalExpress
TE comes standard with the DPO7000C, MSO/DPO5000, MDO4000, MSO/DPO4000B,
MSO/DPO3000, MSO/DPO2000, TDS3000C, TDS2000C, TPS2000B, and TDS1000B
Series oscilloscopes, the DMM4000 Series multimeters, AFG3000 Series
arbitrary/function generators, PWS4000 Series power supplies, and
FCA/MCA Series timer/counters. SIGEXPTE adds extended analysis capabilities.
*1 Compatible with the DPO/DSA70000, MSO70000, DPO7000/C,
MSO/DPO5000, MDO4000, MSO/DPO4000/B, MSO/DPO3000, MSO/DPO2000, TDS2000B/C,
and TDS1000B Series oscilloscopes, the AFG3000 Series arbitrary/function
generators, PWS4000 Series power supplies, and FCA/MCA Series timer/counters.
Requires Microsoft Windows XP/2K or Vista operating system.
NI LabVIEW SignalExpress TE Features – LE Version and SIGEXPTE
Version
|
Features
|
LE Version
|
SIGEXPTE Version
|
|
Instrument Control*2 (Horz Vert Trig Pos)
|
X
|
X
|
|
Customizable Graphs and Interactive Cursors
|
X
|
X
|
|
Tektronix Instrument Support through USB
|
MSO/DPO5000
MDO4000
MSO/DPO4000/B
MSO/DPO3000
MSO/DPO2000
TDS2000B/C
TPS2000B
(with RS-232 to USB adapter cable)
TDS1000B
AFG3000
DMM4000
PWS4000
FCA3000
MCA3000
|
|
Tektronix Instrument Support through Ethernet
|
DPO70000
DSA70000
MSO70000
DPO7000/C
MSO/DPO5000
MDO4000
MSO/DPO4000/B
MSO/DPO3000
MSO/DPO2000
TDS3000B/C
AFG3000
|
|
Tektronix Instrument Support through GPIB
|
DPO/DSA/MSO70000, DPO7000/C Series
DMM4050,
DMM4040
|
|
FCA/MCA3000 Series
|
|
TDS3000B/C Series with TDS3GV module
|
|
TDS2000/1000 Series with TDS2CMA module
|
|
MSO/DPO5000, MDO4000, MSO/DPO4000/B, MSO/DPO3000,
MSO/DPO2000, TDS2000B/C, TDS1000B, PWS4000, and AFG3000 Series with
TEK-USB-488 adapter
|
|
Generic IVI Support for Hundreds of Common Benchtop Instruments
|
X
|
X
|
|
pSpice, SPICE File Conversion from EDA Tools
|
—
|
X
|
|
Save Signals to File
|
X
|
X
|
|
Basic Logging to Disk
|
X
|
X
|
|
Advanced Data Logging (including alarms and events)
|
—
|
X
|
|
Drag and Drop Data into Microsoft Excel and Word
|
X
|
X
|
|
Interactive Reporting
|
—
|
X
|
|
Measurement Trending
|
X
|
X
|
|
Advanced Analysis
|
—
|
Amplitude and Level
Timing and Transition
Histograms
Power Spectrum
Frequency Response
Distortion
Tone Extraction
|
|
Signal Processing
|
—
|
Software Filtering
Scalar/Waveform Math
Analog/Digital
Conversion
Windowing
Scaling and Conversion
|
|
Automated Sweeping and Limit Testing
|
—
|
X
|
|
NI LabVIEW Integration
|
—
|
X
|
*2 Controls only analog channels on MSO70000,
MSO5000, MDO4000, MSO4000, MSO3000, MSO2000 Series Mixed Signal Oscilloscopes.