Features & Benefits
- 100 MHz
and 200 MHz Bandwidths
- Sample Rates up to 2 GS/s Real
Time
- 2 or 4 Fully Isolated and Floating Channels, plus
Isolated External Trigger
- 8 Hours of Continuous Battery
Operation with Two Batteries Installed, Hot Swappable for Virtually
Unlimited Freedom from AC Line Power
- Optional Power Application
Software offers the Broadest Range of Power Measurements at its Price
Point
- Quickly Document and Analyze Measurement Results
with OpenChoice® Software or Integrated CompactFlash® Mass Storage
- FFT Standard on All Models
- Advanced Triggers to Quickly Capture the Event of Interest
- Traditional, Analog-style Knobs and Multilanguage User Interface
for Easy Operation
- Quick Setup and Operation with Autoset
Menu, Autorange, Waveform and Setup Memories, and Built-in, Context-sensitive
Help
- Backlit Menu Buttons for High Visibility
- 11 of the Most Critical Automatic Waveform Measurements
Applications
- Industrial Power Design,
Troubleshooting, Installation, and Maintenance
- Advanced
Electronics Design, Troubleshooting, Installation, and Maintenance
- Automotive Design and Test
- Education
TPS2000B Series Oscilloscopes for Powerful Productivity from Bench
to Field
The TPS2000B Series offers a distinctive range
of capabilities in an oscilloscope with controls and menus you will
find familiar and easy to use. Available in 2- or 4-channel versions,
the TPS2000B Series with IsolatedChannel™ technology provides isolation
from ground and isolation between channels allowing you to take measurements
with less worry about damaging circuitry. Battery power comes standard,
making it a natural choice for field applications. For work on power
electronics, optional software integrates commonly needed power system
measurements into the instrument, speeding up power analysis and troubleshooting.
Make Floating and Differential Measurements – Quickly, Accurately,
Affordably
Unintentionally grounding a circuit under test
is a common cause of poor measurement results and circuit damage.
Connecting two or more grounded probes can cause ground loops, and
if the current is high enough can result in ruined components and
equipment. Most importantly, taking floating measurements without
the proper instruments and probes can pose a safety hazard.
Four IsolatedChannel™ inputs and isolated
external trigger input for quick, accurate, affordable floating and
differential measurements.
Tektronix
IsolatedChannel technology simplifies floating measurements. Unlike
ground-referenced oscilloscopes, the TPS2000B input connector shells
are isolated from each other and from earth ground. Within the specified
600 VRMS maximum float voltage, IsolatedChannel technology
keeps current from flowing between the TPS2000B input BNC shells or
from any BNC shell to earth.
Different passive probes are
available, depending on your application. With the included TPP0101/TPP0201
passive probes, the TPS2000B can measure up to 400 Vp-p. However, to meet the safety rating of the TPP0101/TPP0201, the
reference lead of the probe must be maintained within 30 VRMS relative to ground. Because of this, the TPP0101/TPP0201 probes
are well suited for working on digital and analog circuits in which
the maximum voltage never exceeds 30 VRMS.
Input signal and float voltage maximum
safety ratings.
Measurements on power
conversion electronics usually require probes with higher voltage
ratings. Tektronix offers two passive probes with insulation systems
specifically designed for making floating measurements. Optional P5122
probes, when coupled with the TPS2000B, are suitable for making measurements
on 480 VRMS devices in Category II environments, with a
maximum float voltage of up to 600 VRMS relative to earth
ground. With the optional P5120 probe the TPS2000B can measure up
to 800 Vp-p, with a maximum float voltage within 600 VRMS of ground. With the optional P5120 probe the TPS2000B can
measure up to 800 Vp-p with a maximum float voltage within
600 VRMS of ground. The P5120 is the best choice for making
AC-coupled ripple measurements on high-voltage DC power supplies.
Please see “Characteristics” for complete safety ratings and
specifications.
Selecting the Right Probes for the
Job
|
Scope/Probe (Attenuation)
|
Maximum Safety Ratings
|
TPS2000B Viewable Signal
|
|
Reference Float Safety Rating*1
|
Input Signal Safety Rating
|
On-screen Peak-Peak Voltage (Sinusoid centered at
0 V)
|
On-screen RMS Voltage (Sinusoid centered at 0 V)
|
|
TPS2000B Input (1X)
|
600 VRMS CAT II
|
300 VRMS CAT II
|
40 Vp-p
|
14.1 VRMS
|
|
TPP0101 (100 MHz)
TPP0201 (200 MHz)
|
30 VRMS
|
300 VRMS CAT II
|
400 Vp-p
|
141 VRMS
|
|
P5120 (20X)
|
600 VRMS CAT II
|
1000 VRMS CAT II
|
800 Vp-p
|
282 VRMS
|
|
P5122*2 (100X)
|
600 VRMS CAT II
|
1000 VRMS CAT II
|
2828 Vp-p
|
1000 VRMS
|
*1 Passive probe reference leads
have no attenuation so any working voltage or over-voltage transients
pass straight through to the scope reference. Thus, a passive probe
reference float rating can never exceed the scope reference float
rating.
*2 The P5122 probe should not be used
for AC-coupled measurements on signals with greater than 300 V DC
offset. The P5120 is the recommended probe for measuring ripple on
high-voltage DC supplies.
Speed the Design and Test of
Industrial Power Systems and Circuits
From mobile phones
to industrial motor drives, power conversion technology has enabled
significant advances in size, performance, and energy efficiency.
But even the most basic task of viewing a converter’s input and output
is complicated by multiple voltage references. Multiple references
also make it challenging to view signals from control circuits and
power circuits at the same time. Using ground-referenced oscilloscopes
in these applications, without appropriate differential probes, can
damage circuits and produce bad measurements. For debugging power
conversion electronics, IsolatedChannel technology reduces the risk
of damage and unintended circuit interactions.
For performing
power system measurements, TPS2PWR1 power application software is
available as an option for the TPS2000B. It provides advanced power
measurements right on the oscilloscope, at an entry-level price.
For dialing in the performance of switching components, the
power application software adds important measurements to the TPS2000B,
including automatic switching loss, dv/dt, and di/dt cursor measurements.
Perform three-phase power measurements
of variable frequency drives.
Conduct harmonic distortion measurements
with TPS2PWR1 software.
For measurements
on AC line voltage and for checking the impact on the power distribution
system, the power application software shows harmonic content to the
50th harmonic, and provides phase, reactive power consumption, and
power factor measurements. With the four-channel TPS2014B or TPS2024B,
you can view three-phase voltages or currents.
Two power
“bundles” are available, combining probes and measurement software.
Each package combines four probes with the TPS2PWR1 power application
software, at prices that are lower than if purchased separately. The
TPS2PBND combines four P5120 20X passive, high-voltage probes with
TPS2PWR1 power application software. The TPS2PBND2 combines four P5122
100X passive, high-voltage probes with the power application software.
Quickly Debug and Characterize Signals with DRT Sampling
Technology
Capture elusive glitches – the first
time – with Digital Real-Time (DRT) sampling technology.
Characterize a wide range of signal types on
up to four channels simultaneously with the TPS2000B Series Digital
Real-Time (DRT) sampling technology. This acquisition technology makes
it possible to capture high-frequency events, such as glitches and
edge anomalies, that eludes other oscilloscopes in its class, so that
you can be sure to get an accurate view of your signal.
Easily Analyze and Document Your Measurement Results
Speed documentation and analysis of
measurements results with OpenChoice
® software and integrated
CompactFlash
® mass storage.
Quickly reveal signal interference, crosstalk, and the effects
of vibration with frequency domain analysis using the TPS2000B Series
Fast Fourier Transform (FFT) feature. Then, easily document your measurement
results with the integrated CompactFlash® mass storage.
To capture, save, and analyze your measurement results on
your PC, the included OpenChoice® PC software can be used.
Every TPS2000B Series also ships with a free copy of the special Tektronix
Edition of National Instrument’s LabVIEW SignalExpress™ software for
basic instrument control, data logging, and analysis. The optional
Professional Edition of SignalExpress offers over 200 built-in functions
that provide additional signal processing, advanced analysis, sweeping,
limit testing, and user-defined step capabilities.
SignalExpress
supports the range of Tektronix bench instruments*3, enabling
you to connect your entire test bench. You can then access the feature-rich
tools packed into each instrument from one intuitive software interface.
This allows you to automate complex measurements requiring multiple
instruments, log data for an extended period of time, time-correlate
data from multiple instruments, and easily capture and analyze your
results, all from your PC. Only Tektronix offers a connected test
bench of intelligent instruments to simplify and speed debug of your
complex design.
*3 To see the full range of Tektronix
instruments supported by the Tektronix Edition of NI LabVIEW SignalExpress,
visit www.tektronix.com/signalexpress.
Correlate Your Measurements from Bench to Lab to Field*4
Easily correlate your measurements between
bench, lab, and field with the highly portable TPS2000B Series.
Enjoy virtually unlimited freedom from
an AC power source with hot-swappable batteries.
Use the TPS2000B Series on your bench, in the lab, or
in the field, with the industry’s longest continuous battery life
– 8 hours and beyond – in a highly mobile package. Enjoy virtually
unlimited freedom from an AC power source with hot-swappable batteries.
Optimize Your Productivity
Easily use the oscilloscope even in
environments that challenge operation, with features such as analog-style
knobs per channel and backlit menu buttons.
The oscilloscope has a front-panel layout that most users
will find familiar. Each channel has a dedicated set of scale and
position controls. Reduce your measurement time with features like
autoset, autorange, automatic measurements, probe check wizard, and
context-sensitive help. Backlit menu buttons help you work in a variety
of challenging environments – from bright daylight to dimly lit areas.
Performance You Can Count On
In addition to industry-leading
service and support, every TPS2000B Series oscilloscope comes backed
with a three-year standard warranty.
*4 Please
refer to Environmental and Safety specifications.