Digital Storage Oscilloscopes

TDS2000C Series

Features & Benefits

Key Performance Specifications
  • 200 MHz, 100 MHz, 70 MHz, 50 MHz Bandwidth Models
  • 2- and 4-channel Models
  • Up to 2 GS/s Sample Rate on All Channels
  • 2.5k point Record Length on All Channels
  • Advanced Triggers including Pulse Width Trigger and Line-selectable Video Trigger
Ease-of-Use Features
  • 16 Automated Measurements, and FFT Analysis for Simplified Waveform Analysis
  • Built-in Waveform Limit Testing
  • Automated, Extended Data Logging Feature
  • Autoset and Signal Auto-ranging
  • Built-in Context-sensitive Help
  • Probe Check Wizard
  • Multiple-language User Interface
  • 5.7 in. (144 mm) Active TFT Color Display
  • Small Footprint and Lightweight – Only 4.9 in. (124 mm) Deep and 4.4 lb. (2 kg)
Connectivity
  • USB 2.0 Host Port on the Front Panel for Quick and Easy Data Storage
  • USB 2.0 Device Port on Rear Panel for Easy Connection to a PC or Direct Printing to a PictBridge®-compatible Printer
  • Includes National Instrument’s LabVIEW SignalExpress™ TE Limited Edition and Tektronix OpenChoice® Software for Connecting Your Bench
Lifetime Warranty*1

*1 Limitations apply. For terms and conditions, visit www.tektronix.com/lifetimewarranty.

Performance You Need at a Price You Can Afford

The TDS2000C Digital Storage Oscilloscope Series provides you with affordable performance in a compact design. Packed with standard features – including USB connectivity, 16 automated measurements, limit testing, data logging, and context-sensitive help – the TDS2000C Series oscilloscopes help you get more done, in less time.

Digital Precision for Accurate Measurements


Quickly and easily capture waveforms with advanced triggering.


See all the details other oscilloscopes might miss with Tektronix proprietary digital real-time sampling.

With up to 200 MHz bandwidth and 2 GS/s maximum sample rate, no other digital storage oscilloscope offers as much bandwidth and sample rate for the price. Tektronix proprietary sampling technology provides real-time sampling with a minimum of 10X oversampling on all channels, all the time to accurately capture your signals. Sampling performance is not reduced when using multiple channels.

Critical Tools for Troubleshooting Your Device


Quickly perform an FFT with the advanced math functions.

Advanced triggers – rising/falling edge, pulse width, and video – help you quickly isolate your signals of interest. Once you’ve captured a signal, advanced math capabilities and automated measurements can speed your analysis. Quickly perform an FFT or add, subtract, or multiply waveforms. Sixteen automated measurements quickly and reliably calculate important signal characteristics such as frequency or rise time, while the built-in Limit Test function enables you to easily identify problems in your signal.

Designed to Make Your Work Easy

The TDS2000C Series oscilloscopes are designed with the ease of use and familiar operation you have come to expect from Tektronix.

Intuitive Operation

The intuitive user interface with dedicated per-channel vertical controls, auto-setup, and auto-ranging makes these instruments easy to use, reducing learning time and increasing efficiency.

Help When You Need It, Where You Need It

The context-sensitive Help system provides important information specific to the task you are working on.

The built-in Help menu provides you with important information on your oscilloscope’s features and functions. Help is provided in the same languages as the user interface.

Probe Check Wizard

Check out your probe compensation before making measurements with just one button that starts a fast, easy procedure.

Limit Test

Limit Test provides a quick Pass/Fail comparison of any triggered input signal to a user-defined template.

The oscilloscope can automatically monitor source signals and output Pass or Fail results by judging whether the input waveform is within predefined boundaries. Specific actions can be triggered on violation including stopping waveform acquisition, stopping Limit Test functions, saving the failed waveform data or screen image to a USB memory device, or any combination of the above. This is an ideal solution for manufacturing or service applications where you need to make decisions quickly.

Flexible Data Transfer

Data Logging enables automatic saving of triggered waveforms.


Conveniently use your USB flash drive to store screenshots and waveform data.

The USB host port on the front panel enables you to save your instrument settings, screenshots, and waveform data in a flash. The built-in Data Logging feature means you can set up your oscilloscope to save user-specified triggered waveforms to a USB memory device for up to 24 hours. You can also select the "Infinite" option for continuous waveform monitoring. With this mode you can save your triggered waveforms to an external USB memory device without a duration limitation until the memory device is full. The oscilloscope will then guide you to insert another USB memory device to continue saving waveforms.

Easy PC Connectivity

Easily capture, save, and analyze measurement results with included National Instrument's LabVIEW SignalExpress, Limited Tektronix Edition software.

Easily capture, save, and analyze measurements results by connecting to your PC with the rear-panel USB device port and the included copy of OpenChoice PC Communications Software. Simply pull screen images and waveform data into the stand-alone desktop application or directly into Microsoft Word and Excel. Alternatively, if you prefer not to use your PC, you can simply print your image directly to any PictBridge-compatible printer.

Connect Your Bench for Intelligent Debug

Every TDS2000C Series oscilloscope ships with an included copy of the Limited Tektronix Edition of National Instrument’s LabVIEW SignalExpress for basic instrument control, data logging, and analysis.

SignalExpress supports the range of Tektronix bench instruments*2 enabling you to connect your entire test bench. You can then access the feature-rich tools packed into each instrument from one intuitive software interface. This allows you to automate complex measurements requiring multiple instruments, log data for an extended period of time, time-correlate data from multiple instruments, and easily capture and analyze your results, all from your PC. Only Tektronix offers a connected test bench of intelligent instruments to simplify and speed debug of your complex design.

Performance You Can Count On

In addition to industry-leading service and support, every TDS2000C Series oscilloscope comes backed with a Lifetime Warranty*1 as standard.

*1 Limitations apply. For terms and conditions, visit www.tektronix.com/lifetimewarranty.

*2 For a complete listing of Tektronix instruments supported by NI LabVIEW Signal Express, visit www.tektronix.com/signalexpress.

 

Characteristics

TDS2000C Series Digital Storage Oscilloscopes

   

TDS2001C

TDS2002C

TDS2004C

TDS2012C

TDS2014C

TDS2022C

TDS2024C

Display (QVGA LCD)

TFT

TFT

TFT

TFT

TFT

TFT

TFT

Bandwidth*3

50 MHz

70 MHz

70 MHz

100 MHz

100 MHz

200 MHz

200 MHz

Channels

2

2

4

2

4

2

4

External Trigger Input

Included on all models

Sample Rate on Each Channel

500 MS/s

1.0 GS/s

1.0 GS/s

2.0 GS/s

2.0 GS/s

2.0 GS/s

2.0 GS/s

Record Length

2.5k points at all time bases on all models

Vertical Resolution

8 bits

Vertical Sensitivity

2 mV to 5 V/div on all models with calibrated fine adjustment

DC Vertical Accuracy

±3% on all models

Vertical Zoom

Vertically expand or compress a live or stopped waveform

Maximum Input Voltage

300 VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13 Vp-p AC at 3 MHz

Position Range

2 mV to 200 mV/div +2 V

>200 mV to 5 V/div +50 V

Bandwidth Limit

20 MHz for all models

Input Coupling

AC, DC, GND on all models

Input Impedance

1 MΩ in parallel with 20 pF

Time Base Range

5 ns to 50 s/div

5 ns to 50 s/div

5 ns to 50 s/div

2.5 ns to 50 s/div

2.5 ns to 50 s/div

2.5 ns to 50 s/div

2.5 ns to 50 s/div

Time Base Accuracy

50 ppm

Horizontal Zoom

Horizontally expand or compress a live or stopped waveform

I/O Interfaces

USB Ports

USB host port on front panel supports USB flash drives

USB device port on back of instrument supports connection to PC and all PictBridge-compatible printers

GPIB

Optional

Nonvolatile Storage

Reference Waveform Display

(2) 2.5k point reference waveforms

Waveform Storage without USB Flash Drive

(2) 2.5k point

(2) 2.5k point

(4) 2.5k point

(2) 2.5k point

(4) 2.5k point

(2) 2.5k point

(4) 2.5k point

Maximum USB Flash Drive Size

64 GB

Waveform Storage with USB Flash Drive

96 or more reference waveforms per 8 MB

Setups without USB Flash Drive

10 front-panel setups

Setups with USB Flash Drive

4000 or more front-panel setups per 8 MB

Screen Images with USB Flash Drive

128 or more screen images per 8 MB (the number of images depends on file format selected)

Save All with USB Flash Drive

12 or more Save All operations per 8 MB

A single Save All operation creates 3 to 9 files (setup, image, plus one file for each displayed waveform)

*3 Bandwidth is 20 MHz at 2 mV/div, all models.

Acquisition Modes

Mode

Description

Peak Detect

High-frequency and random glitch capture. Captures glitches as narrow as 12 ns (typical) at all time base settings from 5 μs/div to 50 s/div

Sample

Sample data only

Average

Waveform averaged, selectable: 4, 16, 64, 128

Single Sequence

Use the Single Sequence button to capture a single triggered acquisition sequence

Roll

At acquisition time base settings of >100 ms/div

Trigger System

Characteristic

Description

Trigger Modes

Auto, Normal, Single Sequence

Trigger Types

Trigger

Description

Edge (Rising/Falling)

Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject

Video

Trigger on all lines or individual lines, odd/even or all fields from composite video, or broadcast standards (NTSC, PAL, SECAM)

Pulse Width (or glitch)

Trigger on a pulse width less than, greater than, equal to, or not equal to, a selectable time limit ranging from 33 ns to 10 s

Trigger Source

Characteristic

Description

2-channel Models

CH1, CH2, Ext, Ext/5, AC Line

4-channel Models

CH1, CH2, CH3, CH4, Ext, Ext/5, AC Line

Trigger View

Displays trigger signal while Trigger View button is depressed.

Trigger Signal Frequency Readout

Provides a frequency readout of the trigger source.

Cursors

Characteristic

Description

Types

Amplitude, Time

Measurements

ΔT, 1/ΔT, ΔV

Automatic Waveform Measurements

Period, Frequency, +Width, –Width, Rise Time, Fall Time, Max, Min, Peak-to-Peak, Mean, RMS, Cycle RMS, Cursor RMS, Duty Cycle, Phase, Delay.

Waveform Math

Characteristic

Description

Operators

Add, Subtract, Multiply, FFT

FFT

Windows: Hanning, Flat Top, Rectangular

2048 sample points

Sources

   2-channel models

CH1 – CH2, CH2 – CH1, CH1 + CH2, CH1 × CH2

   4-channel models

CH1 – CH2, CH2 – CH1, CH3 – CH4, CH4 – CH3, CH1 + CH2, CH3 + CH4, CH1 × CH2, CH3 × CH4

Autoset Menu

Signal Type

Autoset Menu Choices

Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems, with undo Autoset.

Square Wave

Single Cycle, Multicycle, Rising or Falling Edge

Sine Wave

Single Cycle, Multicycle, FFT Spectrum

Video (NTSC, PAL, SECAM)

Field: All, Odd, or Even

Line: All or Selectable Line Number

Autorange

Automatically adjust vertical and/or horizontal oscilloscope settings when probe is moved from point to point, or when the signal exhibits large changes.

Display Characteristics

Characteristic

Description

Display

QVGA Active Color TFT

Interpolation

Sin(x)/x

Display Types

Dots, vectors

Persistence

Off, 1 s, 2 s, 5 s, infinite

Format

YT and XY

Multiple-language User Interface and Context-sensitive Help

Characteristic

Description

Languages Available

English, French, German, Italian, Japanese, Korean, Portuguese, Russian*4, Simplified Chinese, Spanish, Traditional Chinese

*4 Requires Russian firmware, indicated by "RUS" suffix.

Environmental and Safety

Characteristic

Description

Temperature

   Operating

0 to +50 °C

   Nonoperating

–40 to +71 °C

Humidity

   Operating and nonoperating

Up to 80% RH at or below +40 °C

Up to 45% RH up to +50 °C

Altitude

   Operating and nonoperating

Up to 3,000 m

Electromagnetic Compatibility

Meets Directive 2004/108/EC, EN 61326-2-1 Class A; Australian EMC Framework

Safety

UL61010-1:2004, CSA22.2 No. 61010-1:2004, EN61010-1:2001, IEC61010-1:2001

Physical Characteristics

Instrument

Dimensions

mm

in.

Width

326.3

12.85

Height

158.0

6.22

Depth

124.2

4.89

Weight

kg

lb.

Instrument Only

2.0

4.4

   With accessories

2.2

4.9

Instrument Shipping

Package Dimensions

mm

in.

Width

476.2

18.75

Height

266.7

10.5

Depth

228.6

9.0

RM2000B Rackmount

mm

in.

Width

482.6

19.0

Height

177.8

7.0

Depth

108.0

4.25

 

Ordering Information

Models

Model

Description

TDS2001C

50 MHz, 2 Ch, 500 MS/s, TFT DSO

TDS2002C

70 MHz, 2 Ch, 1 GS/s, TFT DSO

TDS2004C

70 MHz, 4 Ch, 1 GS/s, TFT DSO

TDS2012C

100 MHz, 2 Ch, 2 GS/s, TFT DSO

TDS2014C

100 MHz, 4 Ch, 2 GS/s, TFT DSO

TDS2022C

200 MHz, 2 Ch, 2 GS/s, TFT DSO

TDS2024C

200 MHz, 4 Ch, 2 GS/s, TFT DSO

Standard Accessories

Accessory

Description

Passive Probes, One per Channel

TPP0101: 100 MHz passive probe for TDS2001C/TDS2002C/TDS2004C

 

TPP0201: 200 MHz passive probe for TDS2012C/TDS2014C/TDS2022C/TDS2024C

Power Cord

(Please specify plug option)

NIM/NIST

Traceable Certificate of Calibration

Documentation

User Manual (Please specify preferred language option)

OpenChoice PC Communications Software

Enables fast and easy communication between a Windows PC and the TDS2000C Series using USB. Transfer and save settings, waveforms, measurements, and screen images

National Instruments SignalExpress Tektronix Edition Interactive Measurement Software – Base Version

A fully interactive measurement software environment optimized for the TDS2000C Series. Enables you to instantly acquire, generate, analyze, compare, import, and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming. Standard TDS2000C Series support for acquiring controlling, viewing, and exporting your live signal. A 30-day trial period of the Professional Version provides additional signal processing, advance analysis, mixed signal, sweeping, limit testing, and user-defined step capabilities. Order SIGEXPTE for permanent Professional Version capability

Limited Lifetime Warranty*5

Covers labor and parts for defects in materials and workmanship for a minimum of 10 years, excluding probes and accessories*6

*5 Lifetime is defined as 5 years after Tektronix discontinues manufacturing the product, but the warranty length shall be at least ten years from date of original purchase. Lifetime warranty is nontransferable, proof of original purchase is required. Limitations apply. For terms and conditions visit www.tektronix.com/lifetimewarranty.

*6 Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the data sheet of each probe and accessory model for its unique warranty and calibration terms.

Power Plug Options

Option

Description

A0

North America power

A1

Universal Euro power

A2

United Kingdom power

A3

Australia power

A5

Switzerland power

A6

Japan power

A10

China power

A11

India power

A12

Brazil power

A99

No power cord or AC adapter

User Manual Options

Option

Description

Translated front-panel overlays included with their respective user manuals.

L0

English manual

L1

French manual

L2

Italian manual

L3

German manual

L4

Spanish manual

L5

Japanese manual

L6

Portuguese manual

L7

Simple Chinese manual

L8

Standard Chinese manual

L9

Korean manual

L10

Russian manual

Recommended Accessories

Accessory

Description

TEK-USB-488

GPIB-to-USB converter

SIGEXPTE

National Instruments SignalExpress Tektronix Edition Interactive Measurement Software – Professional Version

AC2100

Soft Carrying Case for Instrument

HCTEK4321

Hard Plastic Carrying Case for Instrument (requires AC2100)

RM2000B

Rackmount Kit

077-0444-xx

Programmer Manual – English Only

077-0446-xx

Service Manual – English Only

174-4401-xx

USB host to device cable, 3 ft. long

Recommended Probes

Probe

Description

TPP0101

10X Passive Probe, 100 MHz bandwidth

TPP0201

10X Passive Probe, 200 MHz bandwidth

P2220

1X/10X Passive Probe, 200 MHz bandwidth

P6101B

1X Passive Probe (15 MHz, 300 VRMS CAT II rating)

P6015A

1000X High-voltage Passive Probe (75 MHz)

P5100A

100X High-voltage Passive Probe (500 MHz)

P5200

High-voltage Active Differential Probe (25 MHz)

P6021

15 A, 60 MHz AC-current Probe

P6022

6 A, 120 MHz AC-current Probe

A621

2000 A, 5 to 50 kHz AC-current Probe

A622

100 A, 100 kHz AC/DC Current Probe/BNC

TCP303/TCPA300

150 A, 15 MHz AC/DC Current Probe/Amplifier

TCP305/TCPA300

50 A, 50 MHz AC/DC Current Probe/Amplifier

TCP312/TCPA300

30 A, 100 MHz AC/DC Current Probe/Amplifier

TCP404XL/TCPA400

500 A, 2 MHz AC/DC Current Probe/Amplifier

Service Options*6

Option

Description

D1

Calibration Data Report

*6 Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the data sheet of each probe and accessory model for its unique warranty and calibration terms.

 

Select Service

X

STAY INFORMED: Events & Seminars | Email Newsletter | Follow Tektronix on Twitter Follow Tektronix on Facebook Follow Tektronix on Google+ Follow Tektronix on Youtube

MEMBERSHIP: Create an account for exclusive membership privileges. Learn More | Login