Features & Benefits
- Full 30 GHz
Bandwidth to the Probe Tip
- Industry’s Lowest
Probe and Scope System Noise
- TriMode™ Probe
– One Setup, Three Measurements without Adjusting Probe Tip
Connections
- Differential
- Single
Ended
- Common Mode
- Connectivity
- Coaxial Adapters
- • 2.92mm
- • SMP
- P7500 Probe Tip Adapter
- • Use P7500 Series
TriMode Probe Tips
- Probe automatically detects tips
and applies DSP correction filters
- Probe Specific S-parameters
- Unique
DSP filters created from data stored in the probe
- TekConnect® Interface – TekConnect Scope/Probe
Control and Usability
- Direct Control from
Probe Compensation Box or from Scope Menu
Applications
- Examples Include,
but are Not Limited To:
- PCI Express Gen3,
Serial ATA III, HDMI
Combining TriMode Probing with Low Noise Performance
TriMode
Probing enhances productivity by enabling differential, single-ended,
and common mode measurements with a single probe setup. Connecting
a probe to the device under test can be a time consuming activity,
especially if the probe has to be set up differently to make all the
necessary measurements. TriMode Probing improves productivity by reducing
setup time because only one setup is needed to make the three different
types of measurements. Switching between Differential Mode [A-B],
Single-Ended Mode [A-Gnd, B-Gnd], and Common Mode [((A+B)/2)-Gnd]
is as easy as a press of a button.
Changing Input Modes on the probe is as easy as a press of
a button.
As high speed serial data
standards increase in speed and signal swings shrink, probes with
high bandwidth coupled with low noise and high sensitivity are increasingly
important for making accurate measurements.
12 Gb/s 200 mVpp signal measured with a P7630 and
P76CA-292C
The DPO/DSA70000D Series
Oscilloscopes and the P7630 TriMode probe were designed to deliver
the industry’s lowest system noise levels. When used with a
P76CA-xxx Coaxial Adapter, the vertical setting on the oscilloscope
can be set as low as 3.48 mV/div with a system noise <1 mVrms
at 30 GHz bandwidth.
This high sensitivity is critical
for being able to make accurate measurements on low amplitude signals.
The P7630 probe was designed to deliver superior sensitivity and allow
the oscilloscope to directly measure small signals without using a
zoom function. Using a zoom function to look at small signals does
not change the intrinsic noise floor of the instrument which can make
measurements on small signals problematic.
Connectivity
The P7630 probes utilize an interchangeable active tip design
built around a custom probe tip interface using high frequency SMPM
connectors. The P7630 probe features an Automatic Adapter ID function
that recognizes the attached adapter and automatically applies the
correct DSP filters. This feature eliminates the risk of manually
selecting the wrong tip type and is much more efficient for the user.
Coaxial Adapters
Coaxial adapters
enable the probe to act like a differential input channel for the
oscilloscope which effectively doubles the number of differential
signals a single oscilloscope can measure simultaneously.
P76CA-292
30 GHz Bandwidth Coaxial
Adapter with 2.92 mm (F) connectors. This adapter is calibrated
at the input connectors and is ideal for use with off the shelf or
custom cables. Low skew cable pairs should be used to preserve full
bandwidth performance.
P76CA-292C
30 GHz Bandwidth Coaxial
Adapter with 2.92 mm (M) connectors and 6” of high performance
cable. This adapter is calibrated at the input connectors and is ideal
for directly connecting to devices with 2.92 mm or SMA output
connectors.
P76CA-SMP
30 GHz Bandwidth
Coaxial Adapter with SMP (F) connectors and 6” of high performance
cable. This adapter is calibrated at the input connectors and is ideal
for directly connecting to devices with SMP output connectors.
P7500 Series Solder Tip Adapter
P7500 Tip Adapter.
This adapter allows the P7630 probe to use existing Tektronix P7500
probe tips. The P7630 probe amplifier has a 50Ω input. When
combined with a P7500 probe tip, the probe turns into a passive Z0 style
probe with 450Ω of differential input impedance. While Z0 probes
can typically present a significant DC load to the device under test,
the P7630 will minimize the effect of DC loading through the use of
termination voltage adjustment.
P76TA
30 GHz Bandwidth P7500 Tip
Adapter. The probe and oscilloscope system will support up to 30 GHz
of bandwidth when this adapter is used with the P75PST Performance
Solder Tip.
Unique Probe Filters
The P7630
probes contain probe specific S-parameter data. Attaching a P7630
probe to a DSA/DPO70000D oscilloscope transfers this data to the instrument
to create unique system DSP filters based on the specific S-parameter
data of the oscilloscope and the probe. Creating unique filters based
on the specific response of the system is critical as bandwidths increase.
At bandwidths of 30 GHz, small variations in the signal path
can lead to significant variation in frequency response which cannot
be corrected using a nominal DSP filter.