Features & Benefits
Automated Testing
- Performs Single-button Fully Automated Testing for Set of Transmitter Measurements
- Does Not Require Operator Intervention to Conduct Time-consuming Testing
- Reduces the Amount of Time Required to Conduct Testing
- Enables Customers to Test Devices Faster
- Allows Selecting Individual Tests or Group-wise Tests through Tree Structure
100% Test Coverage
- Performs all 49 Fully Automated Tests to the Latest Conformance Test Specification (CTS)
- Benefit from the Complete Test Coverage of all CTS Tests
- Benefit from Testing to the Latest CTS Revision 1.0
Setup Customization
- Modify the Test Setup as per the DUT Configuration
- Unit Intervals are Automatically Calculated based on the DUT Data Rates
Flexible Probing
- Probe the Design Under Test (DUT) using either Differential, TriMode™, or Single-ended Probes
DSI-1 and CSI-2 Decode Testing
- Decodes DSI-1 and CSI-2 Buses
- Decodes Low-power and High-speed States
- Decodes both Short Packets and Long Packets as well as Other Communications Types such as Bus Turn Around (BTA), Escape Mode Commands, and Low-power Data
- Decodes the DCS Command
Event Table, Search, and Error Indicators
- Decodes along with Timestamps for each Event
- Decodes ECC, Checksum, Data Type, Packet Data, etc.
- Indicates Missing Sync, ECC, and Checksum Errors
- Performs Search through Long Acquisitions
Fully Automated Multilane DUT Testing
- Quickly Validate Multilane DUTs using an External RF Switch Additionally
- Automatically Selects One Lane at a Time for Testing
- Does Not Require Operator Intervention to Switch to Subsequent Lanes for Testing
- Save Time and Resources when Testing Multilanes
Characterization/Margin Testing
- Allows Custom Limits or Limit Editing to Perform Margin Testing
- Performs Characterization of Your Design
Fully Automated Temperature Chamber Testing
- Validate Your Mobile Designs in Extreme Test Conditions using XL Cables, High-temperature Tips, and Standard Filter Files, for all High-speed Tests
- Reduces the Amount of Time required to Conduct Testing in Temperature Oven
Detailed Test Reports
- Provides Pass/Fail Summary Table for Each Lane
- Provides Margin Details on Each Test
- Provides “Zoom-in” Screenshots of the Testing Regions for Each Test
- Provides “Single Printable” Consolidated Report for All Tests and All Lanes
- Provides “Single Printable” Consolidated Report for All Tests
Clock Continuous Mode and Escape Mode
- Perform All Tests in Normal Mode or Selective Tests in Clock Continuous Mode
- Perform both Escape Mode (ULPS) and the Normal Mode Tests
Reliable Results
- Achieve Accurate and Reliable Results from a Single Run
Offline/Remote Analysis
- Perform Measurements using either Live or Pre-acquired Waveform Sets
- Allows Remote Execution of Tests
Error Handling
- Identify Setup/Acquisition Issues Quickly through Applicable Error IDs and Exception Information in Test Reports
Applications
D-PHY Transmitter Testing for:
- D-PHY Interface Design
- DSI-1 or CSI-2 Verification
- System Validation and Integration
- Manufacturing Test

Single-button Fully Automated D-PHY Testing
The Tektronix TekExpress® (TEKEXP) Automated Test software is a Windows-based application that runs on any Windows XP*1 computer operating system including Tektronix Windows-based instruments. TekExpress software ordered with Option D-PHYTX provides an automated, simple, and efficient way to test D-PHY Transmitter interfaces and devices consistent to the requirements of the D-PHY Conformance Test Specification Revision 1.0.
Automated Testing –Save Time and Resources
There is no longer a need to be an expert on testing procedures. Remembering the exact steps to take each measurement is time consuming and often requires going back to the D-PHY specifications. D-PHYTX takes the guesswork out of conducting D-PHY Transmitter testing. Even if you remember how to use the test equipment, it is common for even the most experienced operators to forget steps in the procedure or to set up the correct parameters, like applying the correct trigger technique. D-PHYTX allows engineers to simply select the desired tests to run, multiple lanes to be tested, and then work on other tasks while the tests are being executed.
Simple Setup, Test Execution, and Reporting
Setup and test execution is simple with the TekExpress software. The oscilloscope is controlled through the TekExpress automation framework. The TekExpress software provides a Graphical User Interface (GUI) and provides an intuitive workflow through setup and testing.
Setting Up the Bench
When setting up a test, nothing can be simpler than hooking up the test system by looking at a schematic. View the schematic of the selected test with a push of a button.
Instrument Bench Discovery
TekExpress software automatically (or on demand) scans and detects supported instruments connected in your test bench (both Visa supported and non-Visa supported instruments), whether they are connected through LAN, GPIB, or USB. A quick check of the Instrument Bench menu confirms all instruments are networked correctly.
Pass/Fail Report
The Report tab provides a view of test results along with Pass/Fail status, test margin, and images supporting the test results for each lane of the DUT.
Powered by NI TestStand™
The TekExpress automated compliance software uses NI (National Instruments) TestStand to manage and execute its test sequences. A Windows user interface is provided in the TekExpress software for simple and complete operation of compliance measurements. However, if your validation and debug needs go beyond the features offered by the TekExpress software, a full version of NI TestStand can be used to develop higher-level automation sequence to control the TekExpress software.
NI TestStand is the de facto industry-standard test management environment for automating test and validation systems. NI TestStand is used to develop, manage, and execute test sequences, to integrate test modules written in any test programming language through an open and flexible architecture. Customers who own NI TestStand and purchase the TekExpress software will be able to write scripts using NI TestStand that call the TekExpress software with a limited command set. The limited command set allows the NI TestStand user to recall and save TekExpress software setups, start execution, query current execution status, and receive measurement results.
For device validation, it’s often desirable to make multiple runs of a single device using different operating conditions such as temperature and power supply voltages. This is sometimes referred to as ‘four-corners testing’, (testing to low-high temperature and low-high supply voltages). For four-corners testing, NI TestStand supports drivers for a wide range of temperature chambers and power supplies. NI TestStand can be used to control the temperature chamber and then call the TekExpress software for a compliance test using the limited command set. For adjusting power supply voltages, the power supply control sequence file within the TekExpress software can be modified using a standard NI TestStand sequence file. So if your company already uses NI TestStand for automation, your test engineers can incorporate commands to run the TekExpress compliance software directly into their test sequences.
*1 See host system requirements in the Ordering Information section.