AC/DC Current Measurement Systems

TCPA300 • TCP312 • TCP305 • TCP303 • TCPA400 • TCP404XL

Features & Benefits

  • AC/DC Measurement Capabilities
  • DC – 100 MHz, Current Probe Amplifier (TCPA300) uses:
    • DC – 100 MHz, 30 A DC (TCP312)
    • DC – 50 MHz, 50 A DC (TCP305)
    • DC – 15 MHz, 150 A DC (TCP303)
  • DC – 50 MHz, Current Probe Amplifier (TCPA400) Uses:
    • DC – 2 MHz, 750*1 A DC (TCP404XL) (500 A DC Continuous)
  • Automatic Scaling and Units*2 – Oscilloscope On-screen Readout of Magnitude and Amps reduces Measurement Errors with No More Hand Calculations
  • AC/DC Input Coupling
  • Low Insertion Impedance reduces Device Under Test Loading
  • Split-core Construction allows Easy Circuit Connection
  • Status Indicators provide Visual Operating Status and Notification of Potential Error Conditions – Degauss, Probe Open, Overload, Not Terminated into 50 Ω, Noncompatible Probe Type
  • Lower DC Drift and Noise allows Improved Low-level Current Measurements
  • Certified for use in U.S., Canada, and Europe. Complies with applicable IEC Standards.

Applications

  • Development and Analysis Solutions for Designers, Installers, and Service Personnel in Telecomm, Data Comm, Computer, and Semiconductor Power Electronics Environments for:
    • Power Supplies (Switching and Linear)
    • Semiconductor Devices (SCRs, IGBTs, MOSFETs, CMOS, BJTs)
    • Power Inverters/Converters
    • Electronic Ballasts
    • Industrial/Consumer Electronics
    • Mobile Communications (Phone, Satellite, Relay Stations)
    • Motor Drives
    • Transportation Systems (Electronic Vehicles, Electric Trains, Locomotives, Avionics)

Increased Performance and Simplicity

The TCP300 and TCP400 Series AC/DC current measurement family is a highly advanced current measurement system for today's current measurement needs. When connected to Tektronix oscilloscopes with TEKPROBE Level II, TekConnect (w/ TCA-BNC), or TekVPI (w/ TPA-BNC) interfaces, current measurements and calculations are simple and easy.

*1 Derated with duty cycle.

*2 Requires a TDS TEKPROBE oscilloscope or a TekConnect oscilloscope with TCA-BNC.

Meets Today's AC/DC Current Measurement Applications

The TCPA300 amplifier, when used with TCP312, TCP305, or TCP303 probes, provides a wide range of current measurement capability and spans the gap between low-level milliamp measurements to very high current levels. These three probes provide current measurement capabilities of 30 A, 50 A, and 150 A DC continuous. For even higher current levels, the TCPA400 amplifier with the TCP404XL current probe measures 500 A DC continuous and 750 A DC continuous, derated with duty cycle.

Higher frequency performance is available with the TCP312 w/TCPA300 providing ≥100 MHz bandwidth and a maximum current of 30 A DC.

Measurement Errors and Manual Calculations are Now a Thing of the Past

With this new series of current measurement tools, automatic control and on-screen scaling and units is provided for users of Tektronix TDS3000, TDS500, TDS600, TDS700, TDS5000, TDS6000, and TDS7000B Series oscilloscope systems (the DPO3000, MDO/MSO/DPO4000, MSO/DPO5000, and DPO7000 Series oscilloscopes, the TPA-BNC adapter is required).

The TCP300/TCP400 current measurement systems seamlessly integrate with your TDS Series oscilloscope.

Even non-TEKPROBE systems can use the TCPA300/400 Series to make proper current measurements by simply multiplying the measured output voltage on the oscilloscope by the TCPA300/400 Series range setting.

Characteristics

Characteristic

TCP312 w/ TCPA300

TCP305 w/ TCPA300

TCP303 w/ TCPA300

TCP404XL w/ TCPA400

Bandwidth (–3 dB)

DC – 100 MHz

DC – 50 MHz

DC – 15 MHz

DC – 2 MHz*3

Rise Time

≤3.5 ns

≤7 ns

≤23 ns

≤175 ns

Maximum Current Ratings:

High-current Sensitivity Range

10 A/V Range

10 A/V Range

50 A/V Range

1 A/mV Range

   DC (Continuous)

30 A

50 A

150 A

500 A (750 A*4)

   RMS (Sinusoidal)

21.2 A

35.4 A

150 A

500 A

   Peak Pulse

50 A

50 A

500 A

750 A

Low-current Sensitivity Range

1 A/V Range

5 A/V Range

5 A/V Range

N/A

   DC (Continuous)

5 A

25 A

25 A

N/A

   RMS (Sinusoidal)

3.5 A

17.7 A

17.7 A

N/A

   Peak Pulse

50 A

50 A

500 A

N/A

DC Accuracy

(Operating temp 0 °C to 50 °C)

±3% of reading

±3% of reading

±3% of reading (10 °C to 50 °C)

+3%/–6% of reading (0 °C to <10 °C)

±3% of reading

DC Accuracy, Typical

(Operating temp 23 °C ±5 °C)

±1% of reading

±1% of reading

±1% of reading

±1% of reading

Nominal

Maximum Bare Wire Voltage

For use with insulated wires only

600 VRMS CAT I & II

300 VRMS CAT III

Lowest Measurable Current

(at ±3% accuracy at DC)

1 mA

5 mA

5 mA

1 A

Scope set to 1 mV/div and 20 MHz BW Limited

Scope set to 1 mV/div and 20 MHz BW Limited

Insertion Impedance

(See curves below)

0.08 Ω at 1 MHz

0.15 Ω at 10 MHz

0.27 Ω at 50 MHz

0.7 Ω at 100 MHz

0.035 Ω at 1 MHz

0.12 Ω at 10 MHz

0.4 Ω at 50 MHz

0.01 Ω at 1 MHz

0.025 Ω at 5 MHz

0.1 Ω at 15 MHz

0.1 mΩ at 10 kHz

0.6 mΩ at 100 kHz

8 mΩ at 1 MHz

16 mΩ at 2 MHz

Typical

Maximum Amp-Second Product (Based on Amplifier Range setting)

50 A*μS – 1 A/V

500 A*μS – 10 A/V

500 A*μS – 5 A/V

NA – 10 A/V

3,000 A*μS – 5 A/V

15,000 A*μS – 50 A/V

NA – 1 A/mV

AC-coupling Low-frequency Bandwidth

(Low Pass – 3 dB point)

<7 Hz

Displayed RMS Noise

(at 20 MHz bandwidth limit)

≤250 μARMS

≤1.25 mARMS

≤2.5 mARMS

≤250 mARMS

Signal Delay (Delay to output BNC)

17 ns

19 ns

40 ns

80 ns

Inputs (Probe amplifier)

1

Probe Open Indicator

Yes

Overload Indicator

Yes

Termination Indicator

Yes

Noncompatible Probe Indicator

Yes

Safety Certifications

U.S. NRTL Listing

UL3111-1

(Amplifier)

UL3111-2-032 ; UL3111-1

(Probe and Amplifier)

Canadian Certification

CAN/CSA C22.2 No.1010.1

(Amplifier)

CAN/CSA C22.2 No.1010.2.032

CAN/CSA C22.2 No.1010.1

(Probe and Amplifier)

European Union Compliance

EN61010-1/A2

(Amplifier)

EN61010-1/A2; EN61010-2-032

EN61010-1/A2

(Probe and Amplifier)

Other

IEC61010-1/A2 (Amplifier)

IEC61010-2-032

IEC61010-1/A2

(Probe and Amplifier)

Electromagnetic Compatibility

EC Council Directive 89/336/EEC, FCC Part 15, Subpart B Class A, AS/NZS 2064.1/2.

Power Requirements

(TCPA300/TCPA400 Amplifiers)

90 V to 264 V; 47 to 440 Hz; 50 W

Maximum CAT II (Auto Switch)

Power Requirements (Probes)

Requires TCPA300 Amplifier

Requires TCPA400 Amplifier

Probe Model

TCP312

TCP305

TCP303

TCP404XL

Warranty

1 Year

Probe Mechanical Characteristics

Probe Cable Length

1.5 meters (60 inches)

2 meters (78.7 inches)

8 meters (315 inches)

Probe Jaw Size (Max conductor size)

3.8 mm (0.15 inches)

21 mm × 25 mm (0.83 × 1.0 inches)

Length

20 cm (7.87 inches)

26.8 cm (10.55 inches)

26.8 cm (10.55 inches)

Width

1.6 cm (0.625 inches)

4.1 cm (1.60 inches)

4.1 cm (1.60 inches)

Height

3.2 cm (1.25 inches)

15.6 cm (6.13 inches)

15.6 cm (6.13 inches)

Weight

0.15 kg (0.33 lb.)

0.66 kg (1.45 lb.)

0.88 kg (1.90 lb.)

TCPA300 and TCPA400 Mechanical Characteristics

Length

17.3 cm (6.8 inches)

Width

16.7 cm (6.6 inches)

Height

9.14 cm (3.6 inches)

Weight

1.14 kg (2.5 lb.)

Environmental Characteristics

Temperature

   Operating

0 °C to +50 °C (32 °F to 122 °F)

   Nonoperating

–40 °C to +75 °C (–40 °F to 167 °F)

Humidity

   Operating

5% to 95% R.H. to +30 °C (86 °F)

5% to 85% R.H. +30 °C to +50 °C (86 °F to 122 °F)

   Nonoperating

5% to 95% R.H. to +30 °C (86 °F)

5% to 85% R.H. +30 °C to +75 °C (86 °F to 167 °F)

Altitude

   Operating

2000 m (6800 ft.) maximum

   Nonoperating

12,192 m (40,000 ft.) maximum

*3 Calculated from rise time.

*4 Derated w/ duty cycle and frequency.


TCP312 Typical Peak Current Frequency Derating Curve.


TCP312 Typical Insertion Impedance Curve.


TCP312 Typical Specified Operating Area Characteristics.


TCP305 Typical Peak Current Frequency Derating Curve.


TCP305 Typical Insertion Impedance Curve.


TCP305 Typical Specified Operating Area Characteristics.


TCP303 Typical Peak Current Frequency Derating Curve.


TCP303 Typical Insertion Impedance Curve.


TCP303 Typical Specified Operating Area Characteristics.


TCP404XL Typical Peak Current Frequency Derating Curve.


TCP404 Typical Insertion Impedance Curve.


TCP404XL Maximum Current Measurement Time (750 A at 50 °C Ambient).


TCP404XL Maximum Current Measurement Time (600 A at 50 °C Ambient).


TCP404XL Maximum Current Measurement Time (750 A at 23 °C Ambient).

(Note: At 23 °C ambient, 600 A may be measured continuously with the TCP404XL probe.)

Ordering Information

Probes

Product

Description

TCP312

Probe; AC/DC current, DC to 100 MHz; 30 A DC (Requires TCPA300 amplifier)

TCP305

Probe; AC/DC current, DC to 50 MHz; 50 A DC (Requires TCPA300 amplifier)

TCP303

Probe; AC/DC current, DC to 15 MHz; 150 A DC (Requires TCPA300 amplifier)

TCP404XL

Probe; AC/DC current, DC to 2 MHz; 500 A DC (750 A DC derated with duty cycle) (Requires TCPA400 amplifier)

All TCP300/TCP400 Current Probes Include: AC/DC current probe, instruction sheet, probe cover, Certificate of Traceable Calibration.

 

Amplifiers

Product

Description

TCPA300

Amplifier; AC/DC current probe, DC to 100 MHz, (Requires TCP305 or TCP312 or TCP303 probes)

TCPA400

Amplifier; AC/DC current probe, DC to 50 MHz, (Requires TCP404XL probe)

All TCPA300/TCPA400 Current Probe Amplifiers Include: AC/DC current probe amplifier, instruction/service manual, TEKPROBE interface cable, Male-to-Male BNC cable (50 Ω), 50 Ω feedthrough termination, Certificate of Traceable Calibration.

 

TCPA300/TCPA400

Power Plug Options

Option

Description

Opt. A0

North America power

Opt. A1

Universal Euro power

Opt. A2

United Kingdom power

Opt. A3

Australia power

Opt. A5

Switzerland power

Opt. A6

Japan power

Opt. A10

China power

Opt. A11

India power

Opt. A12

Brazil power

Opt. A99

No power cord

Language Options

Option

Description

Opt. L0

English manual

Opt. L5

Japanese manual

Opt. L10

Russian manual

Opt. L99

No manual

All TCP300/TCPA300/TCP400/TCPA400 Series

Service Options

Option

Description

Opt. C3

Calibration Service 3 Years

Opt. C5

Calibration Service 5 Years

Opt. D1

Calibration Data Report

Opt. D3

Calibration Data Report 3 Years (with Option C3)

Opt. D5

Calibration Data Report 5 Years (with Option C5)

Opt. R3

Repair Service 3 Years

Opt. R5

Repair Service 5 Years

Opt. SILV400

Standard Warranty Extended to 5 Years (TCP305, TCP312, TCPA300, and TCPA400)

Opt. SILV600

Standard Warranty Extended to 5 Years (TCP303 and TCP404XL)


Protective covers.

Recommended Accessories

Accessory

Description

016-1923-00

Cover, Small Probe Protective; (for TCP305, TCP312, A6302, A6302XL, A6312, TCP202)

016-1924-00

Cover, Large Probe Protective; (for TCP303, TCP404XL, A6303, A6303XL, A6304XL)

016-1922-00

Case, Transit; Current Measurement Systems

011-0049-02

50 Ω Feedthrough Termination

012-0117-00

50 Ω BNC-to-BNC Coaxial Cable

012-1605-00

TEKPROBE Interface Cable, TCPA300 or TCPA400 Amplifier to TDS Series Oscilloscopes

015-0601-50

Current Loop, 1 Turn, 50 Ω, BNC Connector (for TCP305, TCP312, A6302, A6302XL A6312, TCP202, TCP303, A6303, A6303XL)

174-4765-00

TCPA300/TCPA400 Amplifier Calibration Adapter

067-1478-00

Power Measurements Deskew Fixture, for TCP202, TCP305, TCP312, TCP303, A6302, A6312, A6303, Series Probes

Select Service

X

STAY INFORMED: Events & Seminars | Email Newsletter | Follow Tektronix on Twitter Follow Tektronix on Facebook Follow Tektronix on Google+ Follow Tektronix on Youtube

MEMBERSHIP: Create an account for exclusive membership privileges. Learn More | Login