Active Probes

TAP2500 • TAP3500

Features & Benefits

  • Outstanding Electrical Performance
    • High Probe Bandwidth
    • Fast Probe Rise Time
    • Excellent Signal Fidelity
    • ≤0.8 pF Input Capacitance
    • 40 kΩ Input Resistance
    • –4 V to +4 V Input Dynamic Range
    • –10 V to +10 VDC Input Offset Range
    • ±30 V (DC + peak AC) Max Input Voltage (Nondestruct)
  • Versatile Mechanical Performance
    • Small Compact Probe Head for Probing Small Geometry Circuit Elements
    • DUT Attachment Accessories Enable Connection to SMDs as Small as 0.5 mm Pitch
    • Robust Design for Reliability
  • Easy-to-Use
    • Connects Directly to Oscilloscopes with the TekVPI™ Probe Interface
    • Provides Automatic Units Scaling and Readout on the Oscilloscopes Display
    • Easy Access to Oscilloscope Probe Menu Display for Probe Status/Diagnostic Information and to Control Probe DC Offset
    • Remote GPIB/USB Probe Control through the Oscilloscope

Applications

  • Verification, Debug, and Characterization of High-speed Designs
  • Signal Integrity, Jitter, and Timing Analysis
  • Manufacturing Engineering and Test
  • Signals with Voltage Swings up to 8 Vpk-pk

 

Selecting the right probe for your application is key to attaining the best signal fidelity in your measurements. Active probes provide truer signal reproduction and fidelity for high-frequency measurements. With our ultra-low input capacitance and unique interface, the TAP2500 and TAP3500 Single-ended Active FET probes provide excellent high-speed electrical and mechanical performance required for today’s digital system designs.

Specifically designed for use and direct connection to oscilloscopes with the TekVPI™ probe interface, the TAP2500 and TAP3500 Active FET probes achieve high-speed signal acquisition and measurement fidelity by solving three traditional problems:

  • Lower DUT loading effects with ≤0.8 pF input capacitance and 40 kΩ input resistance
  • Versatile DUT connectivity for attaching to small SMDs
  • Preserves instrument bandwidth at the probe tip for up to 3.5 GHz oscilloscopes

Characteristics

Bandwidth (Probe only) -

≥2.5 GHz (TAP2500).

≥3.5 GHz (TAP3500).

Attenuation (Probe only) - 10:1.

Rise Time (Probe only) -

<140 ps (TAP2500).

<130 ps (TAP3500).

Input Capacitance - ≤0.8 pF.

Input Resistance - 40 kΩ.

Input Dynamic Range - –4 V to +4 V.

Input Offset Range - –10 V to +10 V.

Max Input Voltage (Nondestruct) - ±30 V (DC + peak AC).

Propagation Delay - 5.3 ns.

Physical Characteristics

Dimensions

mm

in.

Width

7.6

0.30

Height

7.6

0.30

Depth

57.2

2.25

Cable Length

1300

51

Weight

kg

lb.

Net 

0.091

0.2 (probe only, using ME lab scale)

Power Requirements

TAP2500 and TAP3500 are powered directly by oscilloscopes with the TekVPI™ probe interface.

Recommended Oscilloscopes

Oscilloscopes with the TekVPI™ probe interface.

Note: For best probe support, download and install the latest version of the oscilloscope software from www.tektronix.com

Environmental

Temperature -  

Operating: 0 °C to +50 °C.

Nonoperating: –40 °C to +71 °C.

Humidity -  

Operating: 5% to 95% Relative Humidity (RH) at up to +30 °C; 5% to 85% RH above +30 °C up to +50 °C; noncondensing.

Nonoperating: 5% to 95% Relative Humidity (RH) at up to +30 °C; 5% to 85% RH above +30 °C up to +75 °C; noncondensing.

Altitude -  

Operating: Up to 4,400 m (15,000 ft.).

Nonoperating: Up to 12,192 m (40,000 ft.).

Regulatory

Emissions Compliance - EN 55011, Class A.

Compliance Labeling -  

C-Tick (Australia / New Zealand)

CE (European Union)

WEEE (European Union)

Ordering Information

TAP2500

2.5 GHz Active Probe.

TAP3500

3.5 GHz Active Probe.

Description

Qty with TAP2500 and TAP3500

Reorder Part Number (Qty)

Y-lead Adapter (2 each) and 3 in. ground lead (3 each)

1 set

196-3456-xx (1 set)

Micro CKT Test Tip

2 each

206-0569-xx (1 ea)

Customizable Ground Lead (set of 5)

1 set

196-3482-xx (1 set)

Color Band Kit

(5 colored pairs)

1 set

016-1315-xx (1 set)

Pogo Pin Ground

(set of 10)

1 set

016-1772-10 (1 set)

Square Pin Socket

(set of 10)

1 set

016-1773-10 (1 set)

Push-in Probe Tip

(set of 10)

1 set

131-5638-11 (1 set)

Right-angle Adapter

(set of 10)

1 set

016-1774-xx (1 set)

SureToe™ Adapter

(set of 4)

1 set

131-6254-xx (1 set)

Antistatic Wrist Strap

1 each

006-3415-xx (1 ea)

Nylon Carrying Case

1 each

016-1952-xx (1 ea)

Plastic Accessory Case

1 each

006-7164-xx (1 ea)

Instruction Manual

1 each

071-xxxx-xx (1 ea)

Optional Accessories

Description

Package Quantity

Ordering Part Number

IC Micro Grabber

2

013-0309-xx

SMA-to-Probe Tip Adapter

1

015-0678-xx

TekVPI Calibration Fixture (for PV)

1

067-1701-xx

Manual Language Options

Opt. L5 - Japanese instruction manual.

Opt. L7 - Simplified Chinese instruction manual.

Service Options

Opt. C3 - Calibration Service 3 years.

Opt. C5 - Calibration Service 5 years.

Opt. D1 - Calibration Data Report.

Opt. D3 - Calibration Data Report 3 Years (with Opt. C3).

Opt. D5 - Calibration Data Report 5 Years (with Opt. C5).

Opt. R3 - Repair Service 3 Years.

Opt. R5 - Repair Service 5 Years.

Opt. SILV900 - Standard Warranty Extended to 5 Years.

Select Service

X

STAY INFORMED: Events & Seminars | Email Newsletter | Follow Tektronix on Twitter Follow Tektronix on Facebook Follow Tektronix on Google+ Follow Tektronix on Youtube

MEMBERSHIP: Create an account for exclusive membership privileges. Learn More | Login